Objectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamma small field of view camera, capable of displaying co-aligned images from both modalities, which can be fused into one image or viewed separately. This study is a preliminary investigation of the performance of the fluorescence component of this camera, including phantom studies and first images from a preclinical pilot study. Methods: The hybrid camera consists of a 1500 µm thick thallium doped caesium iodide columnar (CsI:Tl) scintillator coupled to an electron multiplying charged coupled device (EMCCD). A 1.0mm diameter tungsten pinhole collimator gives a 40mm x 40mm nominal field of view for an 8mm x 8mm CCD detection area. A fluorescence camera was aligned to provide the same field of view as the gamma camera with an LED ring as the excitation source. The performance of the fluorescence imaging was quantified in this study for the fluorophores ICG and IRDye800CW (CW800) using a range of bespoke phantom experiments. In vivo images were also obtained from a preclinical study of a targeted hybrid tracer (cRGD-CW800-TCO + TCO-DOTA-111In) in mice with HT29 colorectal cancer xenografts. RESULTS AND CONCLUSION: The portable hybrid camera prototype has been shown to successfully image dual NIR-gamma tracers using both in vitro and in vivo experimental models. With further development, this camera could be used intraoperatively, offering the benefits of gamma imaging at depth in tissues and high resolution surface NIR fluorescence imaging in a single imaging system.
In this work optical window for infrared region was prepared by using Aluminum Oxide (Al2O3)material as antireflection coating on ZnSe substrate which covers the atmospheric window 3-5µm. the maximum transition was 97% at a wavelength 0f 4.4µm.
Abstract
Metal cutting processes still represent the largest class of manufacturing operations. Turning is the most commonly employed material removal process. This research focuses on analysis of the thermal field of the oblique machining process. Finite element method (FEM) software DEFORM 3D V10.2 was used together with experimental work carried out using infrared image equipment, which include both hardware and software simulations. The thermal experiments are conducted with AA6063-T6, using different tool obliquity, cutting speeds and feed rates. The results show that the temperature relatively decreased when tool obliquity increases at different cutting speeds and feed rates, also it
... Show MoreIn this research, anti-reflection coatings consisting of single and double layers were designed in the IR (8 – 14μm) region to reduce the unwanted reflections of germanium (Ge) substrate. The reflectance of Ge substrate was about 36% per surface. These values were reduced reasonably by using single and double layer anti-reflection. The used layers were promoted in their performance by changing their thickness and refractive indices. The results indicated that the suggested structures are very efficient in reducing the reflectance of the Ge substrates in the selected region. The performance of the double layer antireflection coatings of ZnSe, BaF2 and BiF3 on Ge substrates is presented.
For the most reliable and reproducible results for calibration or general testing purposes of two immiscible liquids, such as water in engine oil, good emulsification is vital. This study explores the impact of emulsion quality on the Fourier transform infrared (FT-IR) spectroscopy calibration standards for measuring water contamination in used or in-service engine oil, in an attempt to strengthen the specific guidelines of ASTM International standards for sample preparation. By using different emulsification techniques and readily available laboratory equipment, this work is an attempt to establish the ideal sample preparation technique for reliability, repeatability, and reproducibility for FT-IR analysis while still considering t
... Show MoreHistidine was determined via measurement of total luminescence (i:e creation of chemiluminescence and insitu irradiation of released light to an acceptor fluorophore molecule to initiate fluorescence from fluorescien molecule in flat – spiral micro cell designed for this measurement . A detailed description of robust linear equation for the range of 0.002 – 0.05 mol.L-1 for a sample size of 70 µL with a correlation coefficient of 0.9879 and a coefficient of determination of 97.59% while for a quadratic model of the same concentration range was 0.9881 correlation coefficient and 97.63% coefficient of determination. Analysis of variance was conducted for both kinds of models . It indicated that their was no significa
... Show MoreCancer constitutes a serious disease and a major health problem in worldwide, a lot of people were infected with this dangerous disease, Therefore, there must be attention to this disease through diagnosis and prevention there. In this study, we determined the relationship between the Cancer and the concentration of trace elements by comparing the concentration trace elements for infected and non-infected people. The trace elements concentrations to nails are one of the diagnostic criteria that easily to detect and dated this disease without any harm to the patient. Eight nails samples were collected from cancer-infected and eight samples from non-infected of the relatives of first-degree. All samples were measured by the concentrations
... Show MoreIraq suffers from serious pollution with harmful particles that have important direct and indirect effects on human activities and human health. In this research, a system for detecting pollutants in the air was designed and manufactured using infrared laser technology. This system was used to detect the presence of pollutants in the dust storms that swept the city of Baghdad which could have a negative impact on human health and living organisms.
The designed detection system based on the use of infrared laser (IR) with a wavelength of 1064 nm was used for the purposes of detecting pollutants based on the scattering of the laser beam from these pollutants. The system was aligned to obtain the best signal for the scattered rays, w
... Show MoreThe purpose of this paper is to extend some results concerning generalized derivations to generalized semiderivations of 3-prime near rings.
Carbon nanotubes are an ideal material for infrared applications due to their
excellent electronic and photo electronic properties, suitable band gap, mechanical
and chemical stabilities. Functionalised multi-wall carbon nanotubes (f-MWCNTs)
were incorporated into polythiophen (PTh) matrix by electro polymerization
method. f-MWCNTs/ PTh nanocomposit films were prepared with 5wt% and
10wt% loading ratios of f-MWCNTs in the polymer matrix. The films are deposited
on porous silicon nanosurfaces to fabricate photoconductive detectors work in the
near IR region. The detectors were illuminated by semiconductor laser diode with
peak wavelength of 808 nm radiation power of 300 mW. FTIR spectra assignments
verify that t