BACKGROUND: Femoral shaft fracture is a common fracture in pediatric age group reaching 62% of all fracture shaft femur in children in spite of rapid union rate and successful conservative treatment but some cases need surgical intervention and one of the methods using plate and screw by the lateral approach. AIM: This study aims to compare functional outcome fixation of mid-shaft femur fracture in children by plate and screws between (subvastus lateralis and transvastus lateralis) regarding infection, union, and limitation of knee movement. PATIENT AND METHOD: The study was done on 30 children who had diaphyseal fracture femur in Al-Kindy Teaching Hospital in period (April 2018–April 2020) with 6 months follow-up, and the patient was divided into two groups: Group A first treated by subvastus lateral approach 15 patients and the second group, Group B by transvastus lateral approach 15 patients and follow-up done for them after 2 weeks, 4 weeks, 6 weeks, 3 months, and 6 months. RESULTS: At week 16 of follow-up all patients in Group A had union, while in Group B, 14 of 50 patients had union and one patient had no union and one patient in Group B had an infection when compared to Group A. From 15 patients of Group A, two patients had limitation of knee movement in the 1st month of follow-up then in the 3rd month of follow-up, no patient had limitation of knee joint movement, while five patients had limitation of knee joint movement in Group B in the 1st month of follow-up and one patient had limitation knee joint movement in the 3rd month of follow-up. CONCLUSIONS: The subvastus lateralis approach results better than transvastus lateralis in union.
The proposal of nonlinear models is one of the most important methods in time series analysis, which has a wide potential for predicting various phenomena, including physical, engineering and economic, by studying the characteristics of random disturbances in order to arrive at accurate predictions.
In this, the autoregressive model with exogenous variable was built using a threshold as the first method, using two proposed approaches that were used to determine the best cutting point of [the predictability forward (forecasting) and the predictability in the time series (prediction), through the threshold point indicator]. B-J seasonal models are used as a second method based on the principle of the two proposed approaches in dete
... Show MoreThe present work aimed to study the efficiency of nanofiltration (NF) and reverseosmosis (RO) process for water recovery from electroplating wastewater and study the factors affecting the performance of two membrane processes. Nanofiltration and reverse osmosismembranes are made from polyamide as spiral wound module. The inorganic materials ZnCl 2 CuCl2 .2H2O, NiCl.2.6H2O and CrCl3.6H2O were used as feed solutions. The operating parametersstudied were: operating time, feed concentrations for heavy metal ions, operating pressure, feed flow rate, feed temperature and feed pH. The experimental results showed, the permeateconcentration increased and water flux decreased with increase in time from 0 to 70 min. Thepermeate concentrations incre
... Show MoreThe present work aimed to study the efficiency of nanofiltration (NF) and reverse osmosis (RO) process for water recovery from electroplating wastewater and study the factors affecting the performance of two membrane processes. Nanofiltration and reverse osmosis membranes are made from polyamide as spiral wound module. The inorganic materials ZnCl2, CuCl2.2H2O, NiCl2.6H2O and CrCl3.6H2O were used as feed solutions. The operating parameters studied were: operating time, feed concentrations for heavy metal ions, operating pressure, feed flow rate, feed temperature and feed pH. The experimental results showed, the permeate concentration increased and water flux decreased with increase in time from 0 to 70 min. The permeate concentrations incre
... Show MoreContinuous escalation of the cost of generating energy is preceded by the fact of scary depletion of the energy reserve of the fossil fuels and pollution of the environment as developed and developing countries burn these fuels. To meet the challenge of the impending energy crisis, renewable energy has been growing rapidly in the last decade. Among the renewable energy sources, solar energy is the most extensively available energy, has the least effect on the environment, and is very efficient in terms of energy conversion. Thus, solar energy has become one of the preferred sources of renewable energy. Flat-plate solar collectors are one of the extensively-used and well-known types of solar collectors. However, the effectiveness of the coll
... Show MoreBackground: Diabetes mellitus is one of the commonest chronic disorders worldwide with a rapid rise in prevalence. In Iraq its prevalence is high especially in elderly age group. Patients with type 2 diabetes mellitus have higher vulnerability for complications, whether microvascular or macrovascular. Ocular complications are common in diabetes mellitus, and comprise diabetic retinopathy, diabetic papillopathy, cataract, glaucoma, dry eye disease and diabetic keratopathy. Diabetic keratopathy involves endothelial and epithelial tissues of the cornea, leading to persistent epithelial defect, corneal erosion, or corneal ulcers.
Aim of the Study: To compare the mean corneal endothelial cell count between patients wi
... Show MoreObjectives of this project were to study the effect of 60% crude alcoholic extract of the seeds of cyperus esculentuson induced endometritis in the mice . The plant of cyperus esculentuswas extracted by preparing Alcoholic extract 60% . One hundred microliters of saline containing Escherichia coli (104cfu) was used to induce endometritis, by a single intracervicallyinjection, and endometritis developed after 2 days from injection. The mice were divided into five groups, The first group were treated with alcoholic extract of cyperus esculentusextract 150mg/kg body weight, the second group was treated with a daily 3mg per kg body weight of gentamicin given intra peritoneal,The third group was treated by 75mg/kg of cyperus esculentusextract an
... Show MoreBackground: Acute appendicitis is regarded as one of the most common inflammation that needs surgical intervention. Different scoring systems have been used for diagnosing of acute appendicitis. ALVARADO score is one of the most widely used score in diagnosing of acute appendicitis, but the accuracy of the latter is insufficiently low in Middle-East patients. Thus a new scoring system called RIPASA score has been designed for diagnosing of acute appendicitis in those patients. The aim of this study is to use RIPASA score and compare its result with ALVARADO score in diagnosing of acute appendicitis.
Subjects and Methods: The study includes 200 patients with symptoms and signs of
... Show MoreBootstrap is one of an important re-sampling technique which has given the attention of researches recently. The presence of outliers in the original data set may cause serious problem to the classical bootstrap when the percentage of outliers are higher than the original one. Many methods are proposed to overcome this problem such Dynamic Robust Bootstrap for LTS (DRBLTS) and Weighted Bootstrap with Probability (WBP). This paper try to show the accuracy of parameters estimation by comparison the results of both methods. The bias , MSE and RMSE are considered. The criterion of the accuracy is based on the RMSE value since the method that provide us RMSE value smaller than other is con
... Show MoreA reliable and environmental analytical method was developed for the direct determination of tetracycline using flow injection analysis (FIA) and batch procedures with spectrophotometric detection. The developed method is based on the reaction between a chromogenic reagent (vanadium (III) solution) and tetracycline at room temperature and in a neutral medium, resulting in the formation of an intense brown product that shows maximum absorption at 395 nm. The analytical conditions were improved by the application of experimental design. The proposed method was successfully used to analyze samples of commercial medications and verified throughout the concentration ranges of 25–250 and 3–25 µg/mL for both FIA and batch procedures, respecti
... Show More