Preferred Language
Articles
/
-hf4no0BVTCNdQwCvxZm
The Relationship Between Orthodontic Force Applied by Monoblock and Salivary Levels of Alkaline Phosphatase and Lactate Dehydrogenase Enzymes
...Show More Authors

Aim: The current study was aimed to determine the relationship between the orthodontic force applied by monobloc and the salivary level of alkaline phosphatase (ALP) and lactate dehydrogenase (LDH) enzymes, considering the time factor after insertion of the appliance and whether there is a correlation between these enzymes. Materials and methods: A sample of 28 growing patients requiring orthodontic treatment with myofunctional appliance (Monoblock) was taken for the current study with an age range 9 to 12 years,all patients had Angle's class II division 1 malocclusion with no or mild crowding, the sample was selected using simple random sampling. Only 16 subjects (10 males and 6 females) were included who follow certain inclusion criteria. Unstimulated saliva was collected from the patients before monoblock insertion, then 1 hour after insertion, followed by 14 days and 28 days. Salivary levels of ALP and LDH were measured using a spectrophotometer and compared with the base line. Results: The results revealed that ALP and LDH levels increased with increasing time after monoblock insertion, and there was the statistically insignificant difference after 1-hour post-insertion for ALP enzyme level, but highly significant after 14 and 28 days. While for LDH level,there was the statistically significant difference after 1-hour post-insertion, but highly significant difference after 14 and 28 days post-insertion. In this regard to the relation between salivary ALP and LDH enzymes levels at different time intervals, showed that there were no significant correlations between the enzymes using Pearson's correlation test. Conclusion: The ALP and LDH salivary enzymes activity is affected by mechanical forces generated by monobloc activator and these enzymes activities can also be increased during the rapid growth phase of childhood such as late infancy and early puberty where the age of subjects was selected in the current study. Clinical significance: The determination of ALP and LDH salivary enzymes activities during the skeletal maturity is crucial for the success of myofunctional monobloc treatment; therefore, saliva can be used as a noninvasive diagnostic tool for determination of chemical biomarkers for detection of bone remodeling process during myofunctional monoblock treatment. © Jaypee Brothers Medical Publishers (P) Ltd.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jun 27 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Synthesis and Characterization of Iron Oxide Nanoparticles by Open Vessel Ageing Process
...Show More Authors

Nano-crystalline iron oxide nanoparticles (magnetite) was synthesized by open vessel ageing process. The iron chloride solution was prepared by mixing deionized water and iron chloride tetrahydrate. The product was characterized by X-Ray, Surface area and pore volume by Brunauer-Emmet-Teller, Atomic Force Microscope (AFM) and Fourier Transform Infrared Spectroscopy(FTIR)  .  The results showed that the XRD in compatibility of the prepared iron oxide (magnetite) with the general  structure of standard iron oxide, and in Fourier Transform Infrared Spectroscopy, it is strong crests in 586 bands, because of  the expansion vibration manner related to the metal oxygen absorption band (Fe–O bonds in the crystals of iron ox

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Comparative Bioequivalence Studies of doxysam and doxycycline (Pfizer) by reversed phase HPLC.
...Show More Authors

Isocratic high performance liquid chromatography on reversed phase a (150x 4.6 mm I.D), 5 ?m ?-Bondapak RP-8 column (with acidic mobile phase allow the separation of doxcycycline hydrochloride with low detection limit of 0.2 µg/ml detected by UV set at 226 nm. The method was validated for Doxycycline between 0.156- to 5 µg/ml. The concentration of doxycycline was assessed in two single dose randomized crossover studies with intervals of one week between two period. In sera of 20 adults healthy male volunteers with average age of (42 + 10) year, body weight 48-85 kg, body height of (160-185cm) after a single dose of doxycycline hydrochoride 100 mg in form of capsules were orally administrated for both formulations. The blood sa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 09 2018
Journal Name
World Rural Observations
Solid cartridges in Determination of Benzidines in River and Wastewater by HPLC
...Show More Authors

A solid Phase Extraction (SPE) cartridges followed by HPLC-UV method is described for the simultaneous quantitative determination of benzidine (BZ) and its substituted 3, 3’-dichlorobenzidine (DCB) and 3, 3’-Dimethylbenzidine (DMB). The Benzidines were separated by liquid chromatography using a C-18 column with UV detector at wave length of 280nm. The mode of Flow was isocratic. The mobile phase was consisted of 75:25 methanol: water, column temperature 50C°, and Flow Rate 1.8ml/min. Calibration curves were linear (R2 = 0.9979-0.9995). LOD (26.36-33.67) µg/L, LOQ (109.98-186.11) µg/L, the Robustness (2.99-4.35), Ruggedness (2.93-3.65).Conditions of extraction by (SPE) cartridges were optimized, the resin used is Octadecyl silica (ODS

... Show More
Publication Date
Fri Sep 30 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Study and Mathematical Modelling of Zinc Removal by Reverse Osmosis Membranes
...Show More Authors

In this study, aromatic polyamide reverse osmosis membranes were used to remove zinc ions from electroplating wastewater. Influence of different operating conditions such as time, zinc concentration and pressure on reverse osmosis process efficiency was studied.  The experimental results showed, concentration of zinc in permeate increase with increases of time from 0 to 70 min, and flux of water through membrane decline with time. While, the concentrations of zinc in permeate increase with the increase in feed zinc concentration (10–300 mg/l), flux decrease with the increment of feed concentration. The raise of pressure from 1 to 4 bar, the zinc concentration decreases and the flux increase. The highest recovery percentage was fou

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 03 2018
Journal Name
Al-khwarizmi Engineering Journal
Recovery of Aluminum from Industrial Waste (Slag) by Melting and Electrorefining Processes
...Show More Authors

Slag of aluminum is a residue which results during the melting process of primary and secondary aluminum production. Salt slag of aluminum is hazardous solid waste according to the European Catalogue for Hazardous Wastes. Hence, recovery of aluminum not only saves the environment, but also has advantages of financial and economic returns. In this research, aluminum was recovered and purified from the industrial wastes generated as waste from both of State Company for Electrical and Electronic Industries (Baghdad/AlWaziriya) and General Company for Mechanical Industries (Babylon/-Al-Escandria). It was found that these wastes contain tiny proportions of other elements such as iron, copper, nickel, titanium, lead, and potassium. Wastes were

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Jan 01 2013
Journal Name
International Journal Of Science And Technology (ijst)
Study of Optical and Structures for TiO2 prepared by Pulse Laser Deposition
...Show More Authors

Publication Date
Wed Apr 01 2015
Journal Name
Journal Of Engineering
Competitive Removal of Cu2+, Cd2+and Ni2+by Iron Oxide Nanoparticle (Fe3O4)
...Show More Authors

A competitive adsorption of Cu2+, Ni2+, and Cd2+ ions from a synthetic wastewater onto nanomaterial was studied.(Fe3O4) nanoparticles obtained from US Research Nanomaterials, Inc., Houston, TX 77084, (USA), was used as nanosorbent. Experimental parameters included pH, initial metal concentrations, and temperature were studied for nanosorbent. The uptake capacity 11.5, 6.07 and 11.1 mg/g for Cu2+, Ni2+and Cd2+, respectively, onto nanosorbent . The optimum pH values was 6 and the contact time was 50 min. for Cu2+, Ni2+and Cd2+, respectively. The equilibrium isotherm for

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 01 2024
Journal Name
Journal Of Optics
Optical and structural characteristics of carbon quantum dots manufacturing by electrochemical method
...Show More Authors

Electrochemical method was used to prepare carbon quantum dots (CQDs). Size of matter was nature when evaluate via X-ray diffraction (XRD). A distinct peak at 2θ equal to 31.6° and three other small peaks at 38.28°, 56.41° and 66.12° were observed. The measures of Fourier Transform Infrared Spectroscopy (FTIR) showed the bonds in the transmittance spectrum are manufactured with carbon nanostructures in view. The first peaks are the O–H stretching vibration bands at (3417 and 2922) cm−1, (C–O–H at 1400, and 1317) cm−1, (C–H), (C=C), (C–O–H), (C=O), and (C–O) bonds at 2850, 1668, 1101, and 1026 cm−1 sequentially. The transmission electron microscopy (TEM) results presented that the spherical CQDs are in shape and on a

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Effect of laser energy and pulses on size and concentration of gold nanoparticles in DDDW by LALP method
...Show More Authors

The size and the concentration of the gold nanoparticles (GNPs)
synthesized in double distilled deionized water (DDDW) have been
found to be affected by the laser energy and the number of pulses.
The absorption spectra of the nanoparticles DDDW, and the
surface plasmon resonance (SPR) peaks were measured, and found to
be located between (509 and 524)nm using the UV- Vis
spectrophotometer. SPR calculations, images of transmission
electron microscope, and dynamic light scattering (DLS) method
were used to determine the size of GNPs, which found to be ranged
between (3.5 and 27) nm. The concentrations of GNPs in colloidal
solutions found to be ranged between (37 and 142) ppm, and
measured by atomic absorptio

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jun 02 2020
Journal Name
International Journal Of Pharmaceutical Research
Association between Serum Leptin Level and Insulin Resistance in Acromegalic Iraqi Patients with Type 2 Diabetes Mellitus
...Show More Authors

View Publication
Scopus (3)
Crossref (2)
Scopus Crossref