Background: Painful elbow joint over the lateral epicondyle especially with resisted wrist extension are common signs of lateral epicondyle tendinopathy, also called tennis elbow. Objective: To evaluate the clinical outcome of local platelet rich plasma (PRP) injection in patients with chronic tennis elbow compared with a steroid (Depomedrol 40 mg) injection. Methods: A total of 88 patients with chronic tennis elbow were treated at Al-Kindy Teaching Hospital and private clinics. All patients had chronic pain for about 24 weeks or more and had failed first line treatment. The patients dividing into two groups, Group A injected with PRP (n = 44), and group B injected with depomedrol 40 mg (n = 44). A good clinical result was demarcated as 25% or more progress on the visual analog scale for pain. All patients followed for 6 months in both group for clinical successful result. Results: At three months (n = 44), in group A reported a perfection of 58.2% in their pain scores while 49.3% in the group B (N = 44). At 6 months follow up, the group A informed a perfection of 74.3% in their pain scores while 58.4 % in the group B. The local elbow tenderness recording at three months was 37.4% in the group A, while in the group B was 48.4%. At six months, 16.1% versus 30.2% recounted major elbow tenderness (P = .009) in groups (A and B) respectively. The clinical improvement rates at three months revealed no changes between both groups while it showed more significant clinically changes in group A ( 87.1%) than in group B (70.1 %) with P value = 0.008 after six months follow up. Conclusion: No important changes were found at 3 months in both groups, but at 6months, clinical significant perfections in patients treated with PRP group (group A)
Were studied changes in the concentration of copper, iron and zinc in blood serum of one hundred patients with chronic kidney and treated dialysis blood were also measured the level of calcium kidney and phosphate Calciotropic in serum of these patients took samples of blood from these patients before and after treatment dialysis vessels as well as the statement of changes in those standards Alkimaahiatih Results were compared with twenty-five healthy people (control group)
Background: Cigarette smoking is an important risk factor that has a clear strong association with the prevalence and severity of chronic periodontitis (CP). Salivary biochemical parameters may be affected by both smoking and CP together. Materials and methods: Eighty systematically healthy male patients were included in this study. They were grouped based on their periodontal and smoking status. Unstimulated whole saliva (UWS) was collected from all subject. Salivary flow rate (FR) was measured during sample collection. Parameters such as salivary pH, total protein (TP), albumin (Alb), total fucose (TF), protein bound fucose (PBF) and C-reactive protein (CRP) were estimated. Results: Salivary flow rate was not altered regarding to smoking
... Show MoreObjective: To assess nurses' exposure to hospitals chronic diseases hazards in Thi-Qar governorate, and to identify the association between nurses' socio-demographic characteristics of age, sex, marital status, place of work, the experience and educational attainment and their exposure to the hazards of chronic diseases. Methodology: A purposive "non-probability" sample of (433) nurses who were selected from four public hospitals in Thi-qar governorate for the period from November 4th 2013 to June 8th of 2014. Results: The study results indicated that that the vast majority of participants have mild chronic di
Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co
Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro
... Show MoreIn the present work, the effect of size of zinc dust particles on
AC argon discharge characteristics are investigated
experimentally. The plasma characteristics are determined by
using optical emission spectroscopy (OES) techniques. The
results illustrated that the electron temperature (Te) in the present
and absent of Zinc dust particle is reduced with increasing of
pressure. The electron temperature decreases with increasing of
Zinc dust size. Excitation temperature Tex is reduces with
increasing of Ar pressure in present and absent of zinc dust
particles. The present of Zinc dust reduce the Tex of Ar in both
Zinc dust size. The electron density increasing in the present and
absent of both zinc dust siz
The effect of Al dust particles on glow discharge regions, discharge
voltage, discharge current, plasma potential, floating potential,
electron density and electron temperature in planar magnetron
sputtering device has been studied experimentally. Four cylindrical
Langmuir probes were employed to measure plasma parameters at
different point on the radial axis of plasma column. The results
shows the present of Al dust causes to increase the discharge voltage
and reduce the discharge current. There are two electron groups in
the present and absent of Al dust particles. The radial profiles of
plasma parameters in the present of dust are non- uniform. The
floating potential of probe becomes more negatively while
Background: Odontogenic cysts include a group of osseodestructive lesions that frequently affect the jaws. Those cysts could derive from odontogenic epithelium and occur in the tooth-bearing regions of the jaws. The aims of this study were to evaluate the immunohistochemical expression of Cyclin D1 in Keratocystic Odontogenic Tumor, Dentigerous cyst and Radicular cyst in epithelium and connective tissue capsule. Materials and Methods: In this study, thirty formalin fixed paraffin embedded tissue blocks of Odontogenic cysts and Tumor, consist of 14 Keratocystic Odontogenic Tumor, 8 dentigerous cysts and 8 radicular cysts were analyzed immunohistochemically for the presence of Cyclin D1 proteins. Results: Strong to moderate expression of Cy
... Show More