Preferred Language
Articles
/
-RaaQogBVTCNdQwCIHVT
Biofunctionalization of polyetheretherketone implant material by bone-forming peptide-2 immobilization
...Show More Authors

Polyetheretherketone (PEEK) has favorable biomechanical properties to be used as an implant material. Unfortunately, it is hydrophobic and does not promote cellular adhesion, which could result in poor integration with bone tissue. Bio-functionalization of PEEK surface with osteogenic peptides derived from bone extracellular matrix proteins is an exciting approach to encourage bone formation around the implant. In the current study, bone-forming peptide-2 was immobilized on PEEK surface using two different methods, using dopamine and a diglycidyl ether as conjugate compounds, respectively. Peptide quantification test revealed that the two strategies resulted in the most amount of peptides were attached with 0.5 mM concentration and no further peptides were grafted with a higher peptide concentration. Both methods showed good peptide stability after agitation in aqueous solution. Peptide grafting was confirmed with ATR-FTIR. Surface characterizations with AFM and wettability tests resulted in a significant increase in surface roughness and surface area ratio for the peptide-grafted PEEK compared to unmodified PEEK, which led to a signifi-cant enhancement in the wettability of the modified PEEK surface

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Oct 28 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Histological and histomorphometric analysis of strontium chloride coated commercially pure titanium implant compared with hydroxyapatite coating
...Show More Authors

Background: In recent years, the immediate loading of dental implants has become more accepted as a standard protocol for the treatment of the edentulous area. Success in implant dentistry depends on several parameters that may improve phenomenon of osseointegration and new bone formation in close contact with the implant. The aim of study was to evaluate the effect of strontium chloride coating of screw shape commercially pure titanium dental implant osseointegration at bone - implant interface by histomorphometric analysis and compare with hydroxyapatite coating at 2 time periods (2 weeks and 6 weeks). Materials and methods: Electrophoretic Deposition Technique (EPD) was used to obtain a uniform coating layer on commercially pure titanium

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Bactericidal Effect of CO2 Laser on Bacteria Associated With Dental Implant Infection: An In Vitro Study
...Show More Authors

One of the most popular causes for implant infection is dental plaque bacteria. Previous studies have shown the bactericidal effect of CO2 laser irradiation on bacteria associated with soft tissue surrounding the implant materials. No published studies have examined the effect of irradiation by CO2 laser on Streptococcus oralis and Staphylococcus aureus.The aim of this study was to evaluate the bactericidal effect of CO2 laser on bacteria that are causing dental implant infections. This study was carried out on two isolates of bacterial species out of 25 samples, isolated from patients having soft tissue infections around the dental implant. These two pure isolates including Streptococcus oralis and Staphylococcus aureus were identified

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 28 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of nano surface modification on CPTi dental implant using chemical method: mechanical and histological evaluation
...Show More Authors

Background The application of nanotechnology to biomedical surfaces is explained by the ability of cells to interact with nanometric features. The aim of this study was to consider the role of nanoscale topographic modification of CPTi dental implant using chemical etching method for the purpose of improving osseointegration. Materials and methods: Commercial pure titanium rod was machined into 20 dental implants. Each implant was machined in diameter about 3mm, length of 8mm (5mm was threaded part and 3mm was flat part). Implants were prepared and divided into 2 groups according to the types of surface modification method used: 1st group (10 implant) remained without nano surface modification (control), 2nd group include (10 implant) etche

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 18 2019
Journal Name
Journal Of Laser Applications
Testing and characterization of sintered β-tricalcium phosphate coat upon zirconia dental implant using Nd:YAG laser
...Show More Authors

This study aims to fabricate and assess the β-tricalcium phosphate (β-TCP) bioactive ceramic coat layer on bioinert ceramic zirconia implants through the direct laser melting technique by applying a long-pulsed Nd:YAG laser of 1064 nm. Surface morphologies, adherence, and structural change in the coatings were evaluated by optical microscopy, field emission scanning electron microscope, hardness, and x-ray diffractometer. The elastic modulus (EM) of the coating was also determined using the nanoindentation test. The quality of the coating was improved when the laser power was 90 W with a decrease in the scan speed to 4 mm s−1. The chemical composition of the coat was maintained after laser processing; also, the Energy Dispersive

... Show More
View Publication
Scopus (8)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Tue Aug 23 2022
Journal Name
International Journal Of Health Sciences
Association between periostin and bone minerals in osteoporosis and osteopenia Iraqi patients
...Show More Authors

Background: osteoporosis is characterized by a reduction in bone mineral density, skeletal microstructure breakdown, increased bone fragility, and fracture susceptibility. Osteopenia is the preceding step to osteoporosis because it causes a decrease in bone mass, osteoporosis reduces a person's quality of life. Periostin (encoded by Postn), its name is derived from the fact that it was first detected in periosteal osteocytes and osteoblasts. Periostin deficiency has been linked to osteoporosis and weak bones. Study objectives: The purpose of this study was to determine periostin levels in serum of Iraqi patients with osteoporosis and osteopenia, and it is also possible to consider periostin as a diagnostic factor to follow the progression o

... Show More
Publication Date
Tue Oct 28 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of bone density after six months from dental implants placement using Computed Tomography
...Show More Authors

Background: Determination of local bone mineral density (BMD) immediately after implant insertion play an important role in implant success rate, may offer comprehensive description of the bone, and give enough information to the surgeon prior to implant insertion and at follow up status. The aim of the present study is to evaluate the changes of local bone density in the dental implant recipient sites by using computerized tomography. Material and method: The sample consisted of (20) dental implants recipient sites, bone density assessment was done twice, immediately after implants insertion and after six months. Results: The mean HU of the bone around the implant insertion site, immediately after implant placement was 552.28 HU, and inc

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 30 2013
Journal Name
Al-kindy College Medical Journal
Evaluation of Serum Osteocalcin and Osteopontin Levels as Bone Biochemical Markers in Postmenopausal Women.
...Show More Authors

Background: Studies discussing the correlation between biochemical markers of bone turnover and the diagnosis of osteoporosis in postmenopausal Iraqi women are rare. This study is devoted to find out the significance of serum osteocalcin (OC) and osteopontin (OPN) levels with the incidence of osteoporosis and its major complication (fracture).Objectives: to investigate the significance of bone turnover biochemical markers; serum osteocalcin and serum osteopontin in evaluating osteoporosis for postmenopausal Iraqi women with and without history of vertebral fracture, as well as to explore the relationship of these markers with bone mineral density (BMD).Methods: Fifty seven postmenopausal women whose ages are fifty years old and over, cat

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 17 2023
Journal Name
International Journal Of Veterinary Science And Medicine
Donor variability of ovine bone marrow derived mesenchymal stem cell - implications for cell therapy
...Show More Authors

View Publication Preview PDF
Scopus (8)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
The substitutions of Strontium by yttrium and their effects on Bi<sub>2</sub>Sr<sub>2</sub>-<sub>x</sub>Y<sub>x</sub>Ca<sub>2</sub>Cu<sub>3</sub>O<sub>10</sub>+<sub>δ</sub> superconducting compound
...Show More Authors
Abstract<p>Superconducting compound Bi<sub>2</sub>Sr2-<sub>x</sub>Y<sub>x</sub>Ca<sub>2</sub>Cu<sub>3</sub>O<sub>10+δ</sub> were Synthesized by method of solid state reaction, at 1033 K for 160 hours temperature of the sintering at normal atmospheric pressure where substitutions Yttrium oxide with Strontium. When Y2O3 concentration (0.0, 0.1, 0.2, 0.3, 0.4 and 0.5). All specimens of Bi<sub>2</sub>Sr<sub>2</sub>Ca<sub>2</sub>Cu<sub>3</sub>O<sub>10+δ</sub> superconducting compounds were examined. The resistivity of electrical was checked by the four point probe technique, It was found th</p> ... Show More
View Publication
Scopus (5)
Crossref (6)
Scopus Crossref
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Determination of Implant Primary Stability: A Comparison of the Surgeon’s Tactile Sense and Objective Measurements
...Show More Authors

Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician cou

... Show More
View Publication Preview PDF
Crossref