The modification of hydrophobic rock surfaces to the water-wet state via nanofluid treatment has shown promise in enhancing their geological storage capabilities and the efficiency of carbon dioxide (CO2) and hydrogen (H2) containment. Despite this, the specific influence of silica (SiO2) nanoparticles on the interactions between H2, brine, and rock within basaltic formations remains underexplored. The present study focuses on the effect of SiO2 nanoparticles on the wettability of Saudi Arabian basalt (SAB) under downhole conditions (323 K and pressures ranging from 1 to 20 MPa) by using the tilted plate technique to measure the contact angles between H2/brine and the rock surfaces. The findings reveal that the SAB's hydrophobicity intensifies in the presence of organic acids, with significant increases in both advancing (θa) and receding (θr) contact angles upon exposure to organic acid at 323 K and 20 MPa. Contrastingly, the application of SiO2 nanoparticles under these conditions results in a marked shift towards hydrophilicity, with θa and θr decreasing substantially, thus indicating an optimal nanoparticle concentration (0.1 wt% SiO2) for effecting the transition from H2-wet to water-wet states. This change in wettability aligns with the known pressure-dependent behavior of contact angles. Moreover, the treatment of organically-aged basalt with 0.1 wt% SiO2 nanofluids at 20 MPa and 323 K enhances the H2 column height significantly, from −424 m to 4340 m, suggesting a reduced risk of H2 migration across the caprock and thereby enhancing both the structural/residual trapping and containment security of H2 within the basaltic formations of Saudi Arabia. This article highlights the crucial role of SiO2 nanofluids in improving the efficacy of H2 storage in basalt, offering a new insight towards the optimization of geological storage solutions for hydrogen, a critical component in the transition to a sustainable energy future.
The steganography (text in image hiding) methods still considered important issues to the researchers at the present time. The steganography methods were varied in its hiding styles from a simple to complex techniques that are resistant to potential attacks. In current research the attack on the host's secret text problem didn’t considered, but an improved text hiding within the image have highly confidential was proposed and implemented companied with a strong password method, so as to ensure no change will be made in the pixel values of the host image after text hiding. The phrase “highly confidential” denoted to the low suspicious it has been performed may be found in the covered image. The Experimental results show that the covere
... Show MoreA theoretical study by using computer model is presented to study the energy characteristics of the vibrational – rotational levels as a function of the vibrational and rotational quantum number, respectively. The calculations were based on the basis of a multilevel model taking into account the non-equilibrium population of the rotational levels. The computational investigation has been performed to examine the vibrational-rotational characteristics of some hydrogen halides chemical laser molecules. This program takes into account the various molecules of chemical lasers such as, Hydrogen Fluoride (HF), Deuterium Fluoride (DF), Hydrogen Chloride (HCl), and Deuterium Chloride (DCl). The practical difficulties associated with this
... Show MoreThe current study aimed to reveal the role of the high school (boys) in the Governorate of Qurayyat (KSA) in promoting intellectual security of students, and whether there were differences in the estimates of the study sample due to the variables; the current position, academic qualification, teaching specialization and years of experience. This study was conducted by applying the analytical descriptive method, and used questionnaire as a tool for data collection. The survey consisted of (44) ite
... Show MoreBackground: techniques of image analysis have been used extensively to minimize interobserver variation of immunohistochemical scoring, yet; image acquisition procedures are often demanding, expensive and laborious. This study aims to assess the validity of image analysis to predict human observer’s score with a simplified image acquisition technique. Materials and methods: formalin fixed- paraffin embedded tissue sections for ameloblastomas and basal cell carcinomas were immunohistochemically stained with monoclonal antibodies to MMP-2 and MMP-9. The extent of antibody positivity was quantified using Imagej® based application on low power photomicrographs obtained with a conventional camera. Results of the software were employed
... Show MorePorous silicon (PS) layers are prepared by anodization for
different etching current densities. The samples are then
characterized the nanocrystalline porous silicon layer by X-Ray
Diffraction (XRD), Atomic Force Microscopy (AFM), Fourier
Transform Infrared (FTIR). PS layers were formed on n-type Si
wafer. Anodized electrically with a 20, 30, 40, 50 and 60 mA/cm2
current density for fixed 10 min etching times. XRD confirms the
formation of porous silicon, the crystal size is reduced toward
nanometric scale of the face centered cubic structure, and peak
becomes a broader with increasing the current density. The AFM
investigation shows the sponge like structure of PS at the lower
current density porous begi
Photonic crystal fiber interferometers (PCFIs) are widely used for sensing applications. This work presented solid core-PCFs based on Mach-Zehnder modal interferometer for sensing refractive index. The general structure of sensor was applied by splicing short lengths of PCF in both sides with conventional single mode fiber (SMF-28).To apply modal interferometer theory collapsing technique based on fusion splicing used to excite higher order modes (LP01 and LP11). A high sensitive optical spectrum analyzer (OSA) was used to monitor and record the transmitted wavelength. This work studied a Mach-Zahnder interferometer refractive index sensor based on splicing point tapered SMF-PCF-SMF. Relation between refractive index sensitivity and tape
... Show MoreDocument source identification in printer forensics involves determining the origin of a printed document based on characteristics such as the printer model, serial number, defects, or unique printing artifacts. This process is crucial in forensic investigations, particularly in cases involving counterfeit documents or unauthorized printing. However, consistent pattern identification across various printer types remains challenging, especially when efforts are made to alter printer-generated artifacts. Machine learning models are often used in these tasks, but selecting discriminative features while minimizing noise is essential. Traditional KNN classifiers require a careful selection of distance metrics to capture relevant printing
... Show MoreA biconical antenna has been developed for ultra-wideband sensing. A wide impedance bandwidth of around 115% at bandwidth 3.73-14 GHz is achieved which shows that the proposed antenna exhibits a fairly sensitive sensor for microwave medical imaging applications. The sensor and instrumentation is used together with an improved version of delay and sum image reconstruction algorithm on both fatty and glandular breast phantoms. The relatively new imaging set-up provides robust reconstruction of complex permittivity profiles especially in glandular phantoms, producing results that are well matched to the geometries and composition of the tissues. Respectively, the signal-to-clutter and the signal-to-mean ratios of the improved method are consis
... Show More