Researcher Image
اكرم فيصل حسين - Akram Faisal Alhuwaizi
PhD - professor
College of Dentistry , Department of Orthodontics
[email protected]
Qualifications

Professor of orthodontics

Teaching materials
Material
College
Department
Stage
Download
Orthodontics
كلية طب الاسنان
تقويم الاسنان
Stage 5
Orthodontics
كلية طب الاسنان
تقويم الاسنان
Stage 5
Orthodontics
كلية طب الاسنان
تقويم الاسنان
Stage 5
Orthodontics
كلية طب الاسنان
تقويم الاسنان
Stage 5
Teaching

Orthodontic materials Advanced orthodontics techniques Orthodontic biomechanics

Publication Date
Sun Dec 13 2020
Journal Name
Clinical And Experimental Dental Research
The efficacy of polyether‐ether‐ketone wire as a retainer following orthodontic treatment
Abstract<sec><title>Objectives

To investigate the efficacy of polyether‐ether‐ketone (PEEK) wire as a fixed orthodontic retainer, by comparing its performance to other retainer wires and optimizing its adhesion to composite bonding materials.

Materials and methods

Retainer wires of 15 mm segments were used, PEEK wires were prepared in cylindrical form with 0.8 mm diameter, and had two surface treatments namely air‐abrasion and conditioning with adhesive system. Three different metallic retainer wires were used for comparison and three tests were performed; two tests measured debonding force and associated wire deflec

... Show More
Scopus (10)
Crossref (10)
Scopus Clarivate Crossref
View Publication
Publication Date
Wed Jan 25 2023
Journal Name
International Journal Of Biomaterials
Surface Characterization of Stainless Steel 316L Coated with Various Nanoparticle Types

Background. Material tribology has widely expanded in scope and depth and is extended from the mechanical field to the biomedical field. The present study aimed to characterize the nanocoating of highly pure (99.9%) niobium (Nb), tantalum (Ta), and vanadium (V) deposited on 316L stainless steel (SS) substrates which considered the most widely used alloys in the manufacturing of SS orthodontic components. To date, the coating of SS orthodontic archwires with Nb, Ta, and V using a plasma sputtering method has never been reported. Nanodeposition was performed using a DC plasma sputtering system with three different sputtering times (1, 2, and 3 hours). Results. Structural and elemental analyses were conducted on the deposited coating

... Show More
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Fri Oct 23 2020
Journal Name
International Journal Of Dentistry
Retention Protocols and Factors Affecting Retainer Choice among Iraqi Orthodontists

Background. To identify the most common retention protocols practiced by Iraqi orthodontists using a specially designed e-survey. Furthermore, this study aimed to assess the effect of sociodemographic factors on the participant’s choice. Methods. Two hundred and twenty-five questionnaires with 23 multiple choice questions were sent to members of the Iraqi Orthodontic Society. The questionnaire was organized into four sections representing information about sociodemographic status of the orthodontists, factors affecting the selection of the retention system, commonly used retainers in the upper arch and lower arch, and duration of the retention system. The chi-square test was used to test the significant association between differe

... Show More
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Tue Aug 22 2023
Journal Name
International Journal Of Biomaterials
Tribology of Coated 316L SS by Various Nanoparticles

Background. Nanocoating of biomedical materials may be considered the most essential developing field recently, primarily directed at improving their tribological behaviors that enhance their performance and durability. In orthodontics, as in many medical fields, friction reduction (by nanocoatings) among different orthodontic components is considered a substantial milestone in the development of biomedical technology that reduces orthodontic treatment time. The objective of the current research was to explore the tribological behavior, namely, friction of nanocoated thin layer by tantalum (Ta), niobium (Nb), and vanadium (V) manufactured using plasma sputtering at 1, 2, and 3 hours on substrates made of 316L stainless steel (SS),

... Show More
Scopus (2)
Crossref (3)
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Thu Jun 15 2017
Discoloration of Stretched Clear Elastomeric Chains by Dietary Media (An in vitro study)

Background: With the increasing demand on esthetic orthodontic appliances, discoloration of clear elastomeric chains and modules remains an issue which concerns both orthodontics and patients. This in vitro study was conducted to evaluate the effect of exposing stretched clear elastomeric chains from six different companies (Ortho Technology, Ormco, Ortho Organizer, American Orthodontics, Opal and G&H companies) to three types of dietary media (tea, coffee and turmeric). Materials and methods: A total of 960 lengths of six modules were cut from short type elastomeric chain; 160 pieces from each brand. The specimens were stretched 50%, placed on plastic boards, and incubated in water at 37°C for 1 day, 7 days, 14 days and 28 days. Once a

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Mon Mar 13 2017
Buccal Cortical Bone Thickness in Iraqi Arab Adults by Cone Beam Computed Tomography for Orthodontic Mini-Implants

ABSTRACT Background: Cortical bone thickness is important for the stability of mini implants. Placing mini implants in sites of favorable cortical bone thickness would guarantee better initial stability and long-term success. The aim of this study was to investigate gender, side and jaw differences of the buccal cortical bone thickness as a guide for orthodontic mini screw placement. Materials and Methods: The sample was selected from the patients attending the Specialized Health Center in Al-Sadr City / 3D department. Thirty patients (15 males and 15 females) were selected and cone beam computerized tomographic images were done. Then the buccal cortical bone thickness was measured at thirteen inter radicular sites in the maxilla and mandib

... Show More
Crossref (3)
Crossref
View Publication Preview PDF
Publication Date
Fri Sep 15 2017
Assessment of the Color Stability of Clear Elastomeric Ligatures (An In Vivo Study)

Background: The desire for an attractive appearing fixed orthodontic appliance fueled the use of ceramic brackets and clear accessories. Elastics are one of the most versatile materials available to orthodontists so studying their effect on the esthetic appearance is important. This an in vivo study, conducted to evaluate the effect of exposing stretched clear elastomeric ligatures to the oral environment from four different companies (OrthoTechnology, Morelli, Ortho Organizer, and Ormco). Materials and Methods: A total of 240 elastomeric modules were examined, 60 modules from each brand. Each of the 60 patients enrolled in the study, received 4 elastomeric modules on the 4 lower incisors, one from each brand. The specimens were placed on t

... Show More
Crossref
View Publication
Publication Date
Fri Sep 15 2017
The Effect Of Bracket Ligation Method On Canine Retraction

Aim: This study aimed to compare different types of ligation methods to obtain maximum tooth movement with the least undesirable rotation. Methods: Titanium brackets bonded to acrylic canine teeth were ligated to straight stainless steel (SS) archwires using four ligation methods (figure-O and figure-8 elastics, SS ligatures, and Leone Slide ligatures). The teeth with the ligatures in place were stored in a water bath at 37ºC for 1 day, 1 week, 2, 4 or 6 weeks before testing. The teeth were retracted through softened wax along the archwire and the amount of tooth movement and degree of rotation were measured. Results: Slide ligatures showed the highest distance of tooth movement and degree of canine rotation followed by figure-O elastics

... Show More
Crossref
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of International Dental And Medical Research
Scopus (1)
Scopus
Publication Date
Sun Jan 01 2023
Journal Name
Dental Hypotheses
Assessment of the Impact of Adhesive and Wires Types on the Tensile Bond Strength of Fixed Lingual Retainers Used in Orthodontics: An In Vitro Study

Introduction: We aimed to assess the impact of adhesive and wires types on the tensile bond strength of fixed lingual retainers. Methods: A total of 160 intact bovine teeth were collected, cleaned, stored in 25% sodium hypochlorite, and randomly assigned to two groups based on the adhesive type: a two-step adhesive and a one-step adhesive. Each group was further divided into four subgroups based on the type of lingual retainer wire, which included (A) 8-strand braided stainless steel wire, (B) three-strand titanium retainer wire, (C) stainless steel chain, and (D) fiber-reinforced retainer. A tensile bond strength test was conducted using a universal testing machine at a controlled speed of 10 mm/min. Result: The 8-strand braided stainles

... Show More
Scopus Clarivate Crossref
View Publication Preview PDF
Publication Date
Sat Oct 01 2022
Journal Name
Journal Of Medicine And Life
The effect of COVID-19 on emergencies and pain among orthodontic patients attending a teaching hospital

This study aimed to evaluate the effect of the COVID-19 outbreak on emergencies and pain among orthodontic patients attending a teaching hospital. The study was conducted among orthodontic patients receiving active orthodontic treatment or in a retention period at the College of Dentistry, University of Baghdad, Iraq. Their participation was voluntary, and they filled out an Arabic-translated questionnaire. The survey included general information, orthodontic problems, and a numerical rating scale for pain assessment. We used descriptive and inferential statistics (frequencies and intersecting frequencies), chi-square test and linear regression. Out of 75 orthodontic patients, only 54 (15 males and 39 females) were included in the s

... Show More
Scopus (2)
Crossref (2)
Scopus Crossref
View Publication Preview PDF
Publication Date
Sun Oct 15 2023
Journal Name
Sumer 3
Treatment of shallow and deep white spot lesions with three different mouthwashes evaluated by laser fluorescence (an in vitro study)

This research aims to find how three different types of mouthwashes affect the depth of artificial white spot lesions. Teeth with various depths of white spot lesions were immersed in either splat mouthwash, Biorepair mouthwash, Sensodyne mouthwash, or artificial saliva (control)twice daily for one minute for 4 weeks and 8 weeks at 37°C. After this immersion procedure, lesion depth was measured using a diagnosed pen score. A one-way analysis of variance, Dunnett T3 and Tukey's post hoc α = .05 were used to analyze the testing data. Splat mouthwash enhanced the WSL remineralization and made the lowest ΔF compared with other mouthwashes in shallow and deep enamel after 4 and 8 weeks of treatment. In the repair groups, after 4 weeks

... Show More
Crossref (1)
Scopus Crossref
View Publication Preview PDF
Publication Date
Thu Aug 01 1996
Journal Name
Unpublished
Temporomandibular disorders in pretreatment orthodontic patients as related to malocclusion

Temporomandibular disorders (TMDs) were investigated in 143 pretreatment orthodontic patients (43 males and 102 females) whose age ranged between 10-25 years at the College of Dentistry, University of Baghdad, Iraq. The study was undertaken to elucidate the prevalence and severity of TMDs in malocclusion patients and to defme the relationships between malocclusion and TMDs. The clinical signs and subjective symptoms were recorded according to the principles introduced by Helkimo (1974b). Subjective symptoms were reported by 65.7% of the patients with 22.40/0 described as severe, and the most common symptoms were TMJ sounds and feeling offatigue. Clinical signs were observed in 81.8% of the sample with 22.4 and 6.3% described as moderate and

... Show More
Preview PDF
Publication Date
Thu Nov 21 2024
The Effect of Orthodontic Force on Salivary Levels of Alkaline Phosphatase Enzyme

Background: Orthodontic tooth movement is characterized by tissue reactions, which consist of an inflammatoryresponse in periodontal ligament and followed by bone remodeling in the periodontium depending on the forces applied. These processes trigger the secretion of various proteins and enzymes into the saliva.The purpose of thi study was to evaluate the activity of alkaline phosphatase (ALP) in saliva during orthodontic tooth movement using different magnitude of continuous orthodontic forces.
Materials and Methods: Thirty orthodontic patients (12 males and 18 females) aged 17-23 years with class II division I malocclusion all requiring bilateral maxillary first premolar extractions were randomly divided into three groups according t

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Indian Journal Of Public Health Research &amp; Development
Effect of Orthodontic Force on Salivary Levels of Lactate Dehydrogenase Enzyme

Orthodontic tooth movement is characterized by tissue reactions, which consist of an inflammatory response in periodontal ligament and followed by bone remodeling in the periodontium depending on the forces applied. These processes trigger the secretion of various proteins and enzymes into the saliva. The purpose of this study was to evaluate the activity of the lactate dehydrogenase (LDH) in saliva during orthodontic tooth movement using different magnitude of continuous orthodontic forces. Thirty orthodontic patients (12 males and 18 females) with ages 17-23 years with class II division I malocclusion all requiring bilateral maxillary first premolar extractions. Those patients were randomly divided into 3 groups according to the magnitude

... Show More
Scopus (1)
Crossref (1)
Scopus Crossref
View Publication
No Events Found