Preferred Language
Articles
/
zxgya5QBVTCNdQwCTxXf
Entrapment of polyethylene terephthalate derived carbon in Ca-alginate beads for solid phase extraction of polycyclic aromatic hydrocarbons from environmental water samples
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Sep 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Environmental Assessment of Polycyclic Aromatic Hydrocarbon Concentrations in Air at Thermal South Power Station of Baghdad
...Show More Authors

Sixteen polycyclic aromatic hydrocarbons (PAHs) concentrations were measured in aerosol samples collected for the period from April 2012 to February 2013 at thermal south power station of Baghdad. Fourty one aerosol sample were extracted with (1:1) dichloromethane and methanol using soxhlet for seventeen hour. The extraction solution was analyzed applying GC/MS. The PAH concentrations outside thermal south power station were higher than those inside it, and higher in summer season than in winter. Naphthalene, pyrene, Anthracene, Indeno [1, 2, 3-cd] pyrene and Phenanthrene were the most abundant PAHs detected in all points at the site sampling. The total polycyclic aromatic hydrocarbon (TPAH) and total suspended particles (TSP) concentrat

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and Determination of Poly Aromatic Hydrocarbons in Vegetables Samples in Baghdad City Using HPLC Technique
...Show More Authors

The Reversed  Phase High Performance Liquid  Chromatography (RP-HPLC) has been used for the separation of  Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which  was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate  of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were   polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage  of the heavy water ,ind

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and determination of poly aromatic hydrocarbons in vegetables samples in Baghdad city using HPLC Technique
...Show More Authors

The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -

... Show More
Publication Date
Fri Sep 24 2021
Journal Name
Indonesian Journal Of Chemistry
Molecular Imprinted of Nylon 6 for Selective Separation of Procaine by Solid-Phase Extraction
...Show More Authors

The study is based on the selective binding ability of the drug compound procaine (PRO) on a surface imprinted with nylon 6 (N6) polymer. Physical characterization of the polymer template was performed by X-ray diffraction and DSC thermal analysis. The imprinted polymer showed a high adsorption capacity to trap procaine (237 µg/g) and excellent recognition ability with an imprinted factor equal to 3.2. The method was applied to an extraction column simulating a solid-phase extraction to separate the drug compound in the presence of tinoxicam and nucleosimide separately and in a mixture of them with a recovery rate more than the presence of tinoxicam and nucleosimide separately and in a mixture of them with a recovery rate of more t

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Mar 23 2020
Journal Name
Baghdad Science Journal
Quantitative Determination of Fluoroquinolones in Contaminated Soils by HPLC with Solid-Phase Extraction
...Show More Authors

This work reports the development of an analytical method for the simultaneous analysis of three fluoroquinolones; ciprofloxacin (CIP), norfloxacin (NOR) and ofloxacin (OFL) in soil matrix. The proposed method was performed by using microwave-assisted extraction (MAE), solid-phase extraction (SPE) for samples purification, and finally the pre-concentrated samples were analyzed by HPLC detector. In this study, various organic solvents were tested to extract the test compounds, and the extraction performance was evaluated by testing various parameters including extraction solvent, solvent volume, extraction time, temperature and number of the extraction cycles. The current method showed a good linearity over the concentration ranging from

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Baghdad Science Journal
Effects of the Ferrits Addition on the Properties of Polyethylene Terephthalate
...Show More Authors

The products of composites material are very sesetive to many variables, such as manufacturing process, additive materials, …. etc. Filler or additive plays a major role to determine the formation of the properties and behavior of the composites. In this study, polyethylene terephthalate-based compounds were produced and characterized. The work is concerned to prepare samples of Polyethylene terephthalate (PET) - zinc-ferrite (ZnFe2O4) with different addition ratio as zinc-ferrite (1, 2, 5, 10, 15 and 20) wt% obtained from mixing the solution with a hot pressing method applied under optimum conditions. The densities of the composites for all samples were calculated. Through the work the diffusion of zinc-ferrite i

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Detection and Removal of Polycyclic Aromatic Hydrocarbon from Selected Areas in Tigris River in Baghdad City
...Show More Authors

Aromatic hydrocarbons present in Iraqi national surface water were believed to be raised principally from combustion of various petroleum products, industrial processes and transport output and their precipitation on surface water.
Polycyclic aromatic hydrocarbons (PAHs) were included in the priority pollutant list due to their toxic and carcinogenic nature. The concern about water contamination and the consequent human exposure have encouraged the development of new methods for
PAHs detection and removal.
PAHs, the real contaminants of petroleum matter, were detected in selected sites along Tigris River within Baghdad City in summer and winter time, using Shimadzu high performance liquid chromatography (HPLC) system.
Analysi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Efficiency of Green Algae Chlorella vulgaris in Remediation of Polycyclic Aromatic Hydrocarbon (Anthracene) from Culture Media
...Show More Authors

The fresh water green alga Chlorella vulgaris was selected to study its ability to degrade one of polycyclic aromatic hydrocarbon (PAHs)known is anthracene (ANT). ANT is widely used in artificial products such as wood preservatives; insecticides; dye and coating materials. This algae was cultivated in CH-10 medium under constant laboratory conditions and exposed to different concentrations (1, 3, and 5 mg/l) of anthracene for 3, 5, 7, 9 and 15 days, with the concentration of ANT measured  by high performance liquid chromatographic analysis (HPLC). The results showed that C.vulgaris has high ability to reduce anthracene to 80% at 1mg/Lcon centration after 3 days and 100% after 5 days, while at 3 and 5 mg / L concent

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Carbofuran with Diazotized Benzidine in Environmental Water Samples
...Show More Authors

A simple, rapid, accurate and sensitive spectrophotometric method has been developed for the determing carbamate pesticides in both pure and water samples. The method is appropriate for the determination of carbofuran in the presence of other ingredients that are usually available in dosage forms. The effect of organic solvents on the spectrophotometric properties of the azo dye and the structure of the resulting product have also been worked out and it is found to be 1:1 benzidine :carbofuran. The method can be successfully applied to determination of carbofuran in water samples. The method is based on diazotization of Benzidine (4, 4 – diamino biphenyl) with sodium nitrite and hydrochloric acid followed by coupling with carbofuran

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jul 01 2022
Journal Name
Sustainable Materials And Technologies
Green approach for fabrication of graphene from polyethylene terephthalate (PET) bottle waste as reactive material for dyes removal from aqueous solution: Batch and continuous study
...Show More Authors

Scopus (26)
Crossref (5)
Scopus Clarivate Crossref