Determination of zinc ions in drinking water distribution systems (PVC pipes) by spectrophotometric method
...Show More Authors

In this work, a method for the simultaneous spectrophotometric determination of zinc which was precipitated into deionized water that is in a commercial distribution systems PVC pipe, is proposed using UV-VIS Spectrophotometer. The method based on the reaction between the analytes Zn2+ and 2-carboxy-2-hyroxy-5-sulfoformazylbenze (Zincon) at an absorption maximum of 620nm at pH 9-10. This ligand is selective reagent. Since the complex is colored (blue), its stoichiometry can be established using visible spectrometry to measure the absorbance of solutions of known composition. The stoichiometry of the complex was determined by Job’s method and molar ratio method and found to be 1:2 (M: L). A series of synthetic solution containing different concentrations of zinc were used to check the prediction ability of the complexation. Water quality samples collected a 100cm PVC system of drinking water in three sizes from different country full with deionized water for different time.

Publication Date
Sat Jun 01 2013
Journal Name
Journal Of Engineering
Assessment of Water Quality Index and Water Suitability of the Tigris River for drinking water within Baghdad City, Iraq
...Show More Authors

In this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended use as well as indicating pollution, water quality management and decision making. The application of Water Quality Index (WQI) with sixteen physicochemical water quality parameters was performed to evaluate the quality of Tigris River water for drinking usage. This was done by subjecting the water samples collected from eight stations in Baghdad city during the period 2004-2010 to comprehensive physicochemical analysis. The sixteen physicochemical parameters included: Turbidity,

... Show More
Publication Date
Tue May 23 2023
Journal Name
Journal Of Engineering
Assessment of Water Quality Index and Water Suitability of the Tigris River for drinking water within Baghdad City, Iraq
...Show More Authors

In this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended use as well as indicating pollution, water quality management and decision making. The application of Water Quality Index
(WQI) with sixteen physicochemical water quality parameters was performed to evaluate the quality of Tigris River water for drinking usage. This was done by subjecting the water samples collected from eight stations in Baghdad city during the period 2004-2010 to comprehensive physicochemical analysis. The sixteen physicochemical parameters included: Turbidity, A

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Mon Mar 12 2018
Journal Name
Arabian Journal For Science And Engineering
Estimate Level of Radon Concentration for Drinking Water in Some Regions of Baghdad City
...Show More Authors

View Publication
Scopus (8)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Baghdad Science Journal
Determination of Sulfacetamide Sodium in Pure and Their Pharmaceutical Formulations by Using Cloud Point Extraction Method
...Show More Authors

      In this study, simple, low cost, precise and speed spectrophotometric methods development for evaluation of sulfacetamide sodium are described. The primary approach contains conversion of sulfacetamide sodium to diazonium salt followed by a reaction with p-cresol as a reagent in the alkaline media.  The colored product has an orange colour with absorbance at λmax 450 nm. At the concentration range of (5.0-100 µg.mL-1), the Beer̆ s Low is obeyed with correlation coefficient (R2= 0.9996), limit of detection as 0.2142 µg.mL-1, limit of quantification as 0.707 µg.mL-1 and molar absorptivity as 1488.249 L.mol-1.cm-1. The other approach, cloud point extraction w

... Show More
View Publication Preview PDF
Scopus (7)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Aip Conference Proceedings
Experimental and theoretical study of (PVC) nanoparticles prepared by laser ablation in ethanol
...Show More Authors

In this manuscript divide into two parts the first experimental and the second theoretical. The experimental part of polyvinyl chloride (PVC) can be used with aluminum (30%). Nanomaterials are synthesized by a laser pulse melting solution by ethanol. The effect of laser on the structural, morphological, optical, and electrical properties of nanoparticles (PVC) was examined by UV spectroscopy, x-ray diffraction (XRD), electron microscopy (TEM). The theoretical part of the DFT can be used to approximate the generalized gradient of the Perdew, Burke, and Ernzerhof (PBE) / 6-31G (d) groups, which were created using additional Gaussian 09 software through Gaussian 5.08. To build PVC nanocrystal pure which chemical formula [(C2H3Cl)n] and build (

... Show More
Publication Date
Mon Dec 25 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectrophotometric Determination of Cefixime Following Simple Diazotization and Coupling with ?-Naphthol
...Show More Authors

Cefixime (CFX) was treated with sodium nitrite and hydrochloric acid for diazotization reaction followed by coupling with ?-Naphthol in alkaline medium to form, a yellow colored azo dye compound which exhibits maximum absorption (?max) at 412 nm where the concentration of (CFX) was determined spectrophotometrically. The optimum reaction conditions and other analytical parameters were evaluated. Beer’s law was obeyed in the concentration range of (1-20) ?g.mL-1 with a molar absorptivity of 34870.5 L.mol-1.cm-1. The limit of detection was found to be 0.1090 ?g.mL-1 and the Sandell's sensitivity value was 0.0130 ?g.cm-2. The proposed method could be successfully applied to

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 26 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Spectrophotometric Determination of Olanzapine via Coupling with Diazotized p-Nitroaniline
...Show More Authors

A new spectrophotometric method has been developed for the assay of olanzapine (OLN.) in pure and dosage forms. The method is based on the diazocoupling of (OLN.) with diazotized p-nitroaniline in alkaline medium to form a stable brown colored water-soluble azo dye with a maximum absorption at 405 nm.  The variables that affect the completion of reaction have been carefully optimized. Beer’s law is obeyed over the concentration range of (0.5-45.0 μg.mL-1) with a molar absorptivity of 1.5777×104 L.mol-1.cm-1.  The limit of detection was  0.3148  Î¼g.mL-1 and  Sandell’s  sensitivity value was 0.0198 μg.cm-2. The propose

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 13 2015
Journal Name
European Journal Of Scientific Research
Determination of Priority Pollutant Phenols in PetroleumRefinery Wastewater and Tigris River Water by SPE-HPLC-UV
...Show More Authors

A solid Phase Extraction (SPE) followed by HPLC-UV method is described for the simultaneous quantitative determination of nine priority pollutant phenols : Phenol, 2- and 4-Nitrophenol, 2,4-Dimethylphenol, 2-, 2,4-Di-, 2,4,6-Tri-, and Penta- chlorophenol, 4 Chloro-3-methylphenol. The phenols were separated using a C-18 column with UV detector at wave length of 280nm. The Flow of mobile phase was isocratic consisted of 50:50 Acetonitrile: phosphate buffer pH=7.1, column temperature 45 C°, Flow Rate 0.7 ml/min. Calibration curves were linear (R2 = 0.9961-0.9995). The RSDs (1.301-5.805)%, LOD(39.1- 412.4) µg/L, LOQ(118.5-1250.8) µg/L, the Robustness (1.55-4.89), Ruggedness (2.82-4.00), Repeatability (2.1-4.95), Recoveries%

... Show More
Publication Date
Mon Jul 01 2019
Journal Name
Iop Conference Series: Materials Science And Engineering
Influence of water in size of Synthesized Carbon Black Nanoparticles from Kerosene by Flame Method
...Show More Authors

View Publication
Scopus (4)
Scopus Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Liquid-Liquid Extraction of Metal Ions Using Aqueous Biphasic Systems
...Show More Authors

An investigation was conducted for the study of extraction of metal ions using aqueous biphasic systems. The extraction of iron, zinc and copper from aqueous sulphate media at different kinds of extractants SCN− , Cl- and I- , different values of pH of the feed solution, phase ratio, concentration of metals, concentration of extractant, concentration of polymer, and concentration of salt was investigated. Atomic absorption spectrophotometer was used to measure the concentration of iron, zinc and copper in the aqueous phase throughout the experiments. The results of the extraction experiments showed the use of SCN− as extractant, pH=2.5, phase ratio=1.5, concentration of metals 1g/l, concentration of extractant 0.06 %, concentration o

... Show More
View Publication Preview PDF
Crossref