Stereo lithography (SLA) three-dimensional (3D) printing process is a type of additive manufacturing techniques that uses digital models from computer-aided design to automatically produce customized 3D objects. Around 30 years, it has been widely utilized in the manufacturing, design, engineering, industrial sectors and its applications in dentistry for manufacturing prosthodontics are very important. The stereo lithography technology is highly regarded because it can produce items with excellent precision especially when selecting the best process parameters. This review article offers a useful and scientific summary of SLA three-dimensional printing technology and its brief history. The specific type of 3D printers which is SLA type based on light curing resin and material overview is also presented. Moreover, the survey was conducted to gain substantial knowledge of the various advantages and disadvantages of SLA 3D printing. According to this study, a summary has been specified on the accuracy of SLA 3D printers and various factors that affected its accuracy and dimension measurement namely layer thickness, normal exposure time, bottom or top exposure time, post processing and room temperature. The majority of works in the literatures conducted till date are on improving the physical part attributes like dimensional accuracy and surface roughness but the improving of the mechanical properties have received less attention and need more focusing in the future works.
In this paper, the first integrals of Darboux type of the generalized Sprott ET9 chaotic system will be studied. This study showed that the system has no polynomial, rational, analytic and Darboux first integrals for any value of . All the Darboux polynomials for this system were derived together with its exponential factors. Using the weight homogenous polynomials helped us prove the process.
The present study was conducted in order to focus on the effect of the addition of Carnitine and Niacin on some blood serum parameters of Common Carp Cyprinus Carpio. 48 fish carp mean weight 44.13 gm were distributed randomly on four feeding treatments (12 fish each) with replicates (6 fish each) in 8 glass aquaria. Treatments were as follows: fish were fed on basic diet without any addition and conducted as control (T1); addition of 200 mg Carnitine/ Kg diet, (T2) addition of 28 mg Niacin/Kg diet (T3), addition of a mixture of 200 mg Carnitine and 28 mg Niacin/ Kg diet as (T4). The experiment was conducted for 70 days and the results showed an increase in the Cholesterol concentration of T1 (187.6 mg/ 100 ml) and differed s
... Show MoreIn this study forty mature albino rats were used wich were randomly divided into five groups ,four groups were adminstrated Phoenix dactylifera pollen grains suspension at concertenrations (18,54,108,and 216)mg/ kg body weight by oral administration while the fifth group was considered as a control group.Experiment continued for 40 days then rats were sacrificed and samples of blood were collected for determination of some biochemical parameters (total protein ,total cholesterol ,LDLc and HDLc).Testis were removed for preparation histological sections to measures the diameters of seminferous tubules ,thickness of seminiferous epithelium and the numbers of spermatogenic cells.
... Show MoreAge and BMI may be used to diagnosis of thyroid autoimmune disease. One hundred Iraqi women with age ranged from 18 to 60 years participate in this research, 50 of them were hypothyroidism patients, 30 were hyperthyroidism patients and the other 20 were euthyroidism served as controls. Blood samples were collected from the studied subjects to determine thyroid profile [free triiodothyronine (FT3), free tetraiodothyronine (FT4) and thyroid stimulating hormone (TSH)], thyroid antibodies [anti-thyroid peroxidase (anti-TPO), anti-thyroglobulin (anti-Tg), and anti-thyroid stimulating hormone receptor (anti-TSHR)], and levels of vitamin D (vit D), calcium (Ca), and phosphorus (P) using different analysis techniques. When the effect of age
... Show MoreImproving the quality of health services in the health sector is an important and necessary matter that must be taken care of and improved, and this study seeks to demonstrate the role of quality costs in improving the quality of health services and achieving a high level of quality to satisfy the beneficiaries and to provide health services of good quality, and the research concluded that the main point of service provision Good health is the costs of prevention and evaluation (costs of quality conformity) and attention to it, and that technical competition contributes greatly to the development of the level of quality, as well as the use of health and medical staff with competent expertise, and that the costs of internal failure and th
... Show MoreSchizophrenia (ZP) is a common devastating cognitive disorder; however, the etiology of its incidence remains largely unclear yet. Although some evidence blames both environ ment and genetic factor as main drivers of ZP, but the clear mechanism of their effect elusive till now. Of interest, severe anemia conditions can lead to hypoxia in CNS which disturbs the normal structures and functions of some area in the brain resulting in abnormalities in the neurons communications and decrease synaptic plasticity. Additionally, modulation of cytoskeleton constituents is thought to participate to ZP development. Recently, it has been revealed that iron deficiency, which is the main cause of anemia, has a significant impact on the cytoskeleton
... Show MoreThe photonconductor detectors CdSe:Cu was fabricated as a thin film of (1 μm) in thickness using vacuum evaporation technique. doping with copper was made using vacuum annealing at 350oC under argon atmosphere . The spectral responsivity and spectral detectivity of the detector were determined as a function of incident wavelength on the sample. A remarkable improvement in performance was absorbed for the specimen, which doping with (1-5 wt%) Cu.
The spectral response increases with increasing of wavelength for incident radiation to maximum value, after that , it reduced sharply . There is a shifting for peak responsivity indirect of higher wavelength. The detectivity was increased with doping but its decreased as the concentration in