Enhancement of the performance for hybrid solar air conditioning system was presented in this paper. The refrigerant temperature leaving the condenser was controlled using three-way valve, this valve was installed after the compressor to regulate refrigerant flow rate towards the solar system. A control system using data logger, sensors and computer was proposed to set the opening valve ratio. The function of control program using LabVIEW software is to obtain a minimum refrigerant temperature from the condenser outlet to enhance the overall COP of the unit by increasing the degree of subcooled refrigerant. A variable load electrical heater with coiled pipe was used instead of the solar collector and the storage tank to simulate the sola
... Show MoreIn IRAQ, the air conditioners are the principal cause of high electrical demand. In summer, the outer temperature sometimes exceeds 500C which significantly effects on the A/C system performance and power consumed. In the present work, the improvement in mechanical and electrical performance of split A/C system is investigated experimentally and analytically. In this paper, performance and energy saving enhancement of a split-A/C system was experimentally investigated to be efficiently compatible with elevated temperature weathers. This improvement is accomplished via Smart Control System integrate with Proportional-Integral- Differential PID algorithm. The PIC16F877A micro-controller has been programmed with the PID and PWM c
... Show MoreHemipteran species of alfalfa plant surveyed in Abu Ghraib, Baghdad during the months of April, May and October of 2010. The study was registered, eight species belonging to eight genera and six families. The results showed that Deracoris sp. Kirschbaum,1855 and Campylomma diversicornis Reuter, 1878 the most abundant species while Lygaeus pandurus Scop. and Pyrrhocorius apterus (Linnaeus 1758) were the lowest during the study period.
The aim of current study is to analyze the content of intermediate stage biology books based on multiple intelligences. To do this, the researcher used the descriptive analytical approach. To analyze the three books of the intermediate stage, the author adopted content analysis tool and area unit. They were exposed to group of experts in methods of teaching biology, and measurement and evaluation. The findings of the study have shown a significant difference between what was expected and the observation of the multiple intelligences for the three biology books excluded the (social, musical, and kinetic intelligence), and there is no significant difference between the analysis' result of the biology books and the expectations of b
... Show MoreArtificial roughness applied to a Solar Air Heater (SAH) absorber plate is a popular technique for increasing its total thermal efficiency (ηt−th). In this paper, the influence of geometrical parameters of V-down ribs attached below the corrugated absorbing plate of a SAH on the ηt−th was examined. The impacts of key roughness parameters, including relative pitch p/e (6–12), relative height e/D (0.019–0.043), angles of attack α (30–75°), and Re (1000–20,000), were examined under real weather conditions. The SAH ηt−th roughened by V-down ribs was predicted using an in-house developed conjugate heat-transfer numerical model. The maximum SAH ηt−th was shown to be 78.8% as predicted under the steady-state condition
... Show MoreA low-cost reverse flow plasma system powered by argon gas pumping was built using homemade materials in this paper. The length of the resulting arc change was directly proportional to the flow rate, while using the thermal camera to examine the thermal intensity distribution and demonstrating that it is concentrated in the centre, away from the walls at various flow rates, the resulting arc's spectra were also measured. The results show that as the gas flow rate increased, so did the ambient temperature. The results show that the medium containing the arc has a maximum temperature of 34.1 ˚C at a flow rate of 14 L/min and a minimum temperature of 22.6 ˚C at a flow rate of 6 L/min.
In this paper, a procedure to establish the different performance measures in terms of crisp value is proposed for two classes of arrivals and multiple channel queueing models, where both arrival and service rate are fuzzy numbers. The main idea is to convert the arrival rates and service rates under fuzzy queues into crisp queues by using graded mean integration approach, which can be represented as median rule number. Hence, we apply the crisp values obtained to establish the performance measure of conventional multiple queueing models. This procedure has shown its effectiveness when incorporated with many types of membership functions in solving queuing problems. Two numerical illustrations are presented to determine the validity of the
... Show MoreWith the shift of narration and the revolution against the traditional methods which were dominated by the authorial intrusion and the single narrative voice, there appeared new forms that go along with the change in methods of narration. Form becomes the representation which equips us to understand more fully aspects of existence outside of art. Form is the objectifying of idea, and its excellence depends upon its appropriateness to the idea.1 One of the most important approaches to writing fiction is the power of point of view.
In the strategy of 'point of view' lies the secret of art and, as Norman Friedman indicates, it provides a method for distinguishing the possible degrees of authorial extinction in the narrati