This study aimed to assess the efficiency of Nerium oleander in removing three different metals (Cd, Cu, and Ni) from simulated wastewater using horizontal subsurface flow constructed wetland (HSSF-CW) system. The HSSF-CW pilot scale was operated at two hydraulic retention times (HRTs) of 4 and 7 days, filled with a substrate layer of sand and gravel. The results indicated that the HSSF-CW had high removal efficiency of Cd and Cu. A higher HRT (7 days) resulted in greater removal efficiency reaching up to (99.3% Cd, 99.5% Cu, 86.3% Ni) compared to 4 days. The substrate played a significant role in removal of metals due to adsorption and precipitation. The N. oleander plant also showed a good tolerance to the uptake of Cd, Cu, and Ni ions from water. The highest removal of the heavy metals indicated that the HSSF-CW would be a promising technology for heavy metal contaminated wastewater as well as in electroplating and manufacturing industries.
Abstract Background: One of the most important methods to replace lost teeth is dental implants. In order to increase the strength of connection of the implant with the jaw bone to provide early loading after placement, implant is coated by different coating materials that achieved that purpose. The aim of this study was to evaluate the influence of coating CP Ti implant with calcium carbonate on the strength of bone-implant interface after two and six weeks of implantation in rabbit femur bone by torque removal test, histological and histomorphometric analysis. Materials and methods: Coating the surface of commercially pure titanium screws with extra pure synthetic calcium carbonate via electrophoretic deposition method (EPD) was done. The
... Show MoreIn this research, the preparation of bidentate Schiff base was carried out via the condensation reaction of both the salicylaldehyde with 1-phenyl-2,3-dimethyl-4-amino-5-oxo-pyrazole to form the ligand (L). The mentioned ligand was used to prepare complexes with transition metal ions Mn(II), Co(II), Ni(II), Cu(II) and Zn(II). The resulting complexes were separated and characterized by FTIR and UV-Vis spectroscopic technique. Elemental analysis for Carbon, Hydrogen and Nitrogen elements, electronic spectra of the ligand and complexes were obtained, and the magnetic susceptibility tests were also achieved to measure the dipole moments. The molar conductivities were also measured and determination of chlorine content in the complexes and
... Show MoreThe current paper focuses on the studying the forms of (even-even) nuclei for the heavy elements with mass numbers in the range from (A=226 - 252) for isotopes. This work will consist of studying deformation parameters which is deduced from the "Reduced Electric Transition Probability" which is in its turn dependent on the first Excited State . The "Intrinsic Electric Quadrupole Moments" (non-spherical charge distribution) were also calculated. In addition to that the Roots Mean Square Radii (Isotope Shift) are accounted for in order to compare them with the theoretical results.
The difference and variation in shapes of nuclei for the selected isotopes were detected using &
... Show MoreThirty uropathogenic E. coli isolates were isolated from hospitalized and non hospitalized patients, complaining of urinary tract infections, of Al-Kadhymia Teaching Hospital and subjected to tRNA extraction. A method of tRNA extraction was modified by adding sodium dodecyl sulfate (SDS) instead of urea. Polyacrylamide gel electrophoresis and two methods of staining, ethidium bromide staining and silver staining, as well as spectrophotometric detection were used.
The performance of a synergistic combination of electrocoagulation (EC) and electro-oxidation (EO) for oilfield wastewater treatment has been studied. The effect of operative variables such as current density, pH, and electrolyte concentration on the reduction of chemical oxygen demand (COD) was studied and optimized based on Response Surface Methodology (RSM). The results showed that the current density had the highest impact on the COD removal with a contribution of 64.07% while pH, NaCl addition and other interactions affects account for only 34.67%. The optimized operating parameters were a current density of 26.77 mA/cm2 and a pH of 7.6 with no addition of NaCl which results in a COD removal efficiency of 93.43% and a specific energy c
... Show MoreThe ï¤- Multiple mixing ratios of ï§-transitions from levels of 56Fe populated in 56 56 ( , ) Fe n n Fe ï§ ï‚¢ reactions are calculated by using const. S.T.M. This method has been used in other works [3,7] but with pure transition or with transitions that can be considered as pure transitionsØŒ in our work we used This method for mixed ï§ - transitions in addition to pure ï§ - transitions. The experimental angular distribution coefficients a2 was used from previous works [1] in order to calculet ï¤- values. It is clear from the results that the ï¤- values are in good agreement or consistent, within associated errors, with those reported previously [1]. The discrepancies that occur
... Show MoreAbstract. In this research, the uranium concentration in (16) water samples collected from some agricultural areas surrounded with AlTuwitha nuclear site in Baghdad-Iraq was measured by using a CR-39 detector. The concentration of uranium in this study was from (0.6 ± 0.33mg/l) to (2.51 ± 0.49 mg/l), and the weighted average for the concentrations (1.262 ± 0.402 mg/l). The results showed it is a concentration of uranium level in water samples studied is higher than the allowed limit recommended by WHO and ICRP.
This research introduced the derivation of mathematical equations to calculate the Cartesian and geographical coordinates of a site situated at a far distance from the observer position by using GPS data. The geographical coordinates (ϕobs., λ obs., hobs.) for observer position were transformed to Cartesian coordinates (X obs., Y obs., Z obs.) of observer position itself. Then the Cartesian coordinates of unknown position mathematically were calculated from these calculated equations, and its transformed to geographical coordinates of (ϕunk., λunk.) position.