Preferred Language
Articles
/
zYbAt4YBIXToZYAL77Nw
Performance of Segmental Post-Τensioned Concrete Beams Exposed to High Fire Temperature
...Show More Authors

The present study illustrates observations, record accurate description and discussion about the behavior of twelve tested, simply supported, precast, prestressed, segmental, concrete beams with different segment numbers exposed to high fire temperatures of 300°C, 500°C, and 700°C. The test program included thermal tests by using a furnace manufactured for this purpose to expose to high burning temperature (fire flame) nine beams which were loaded with sustaining dead load throughout the burning process. The beams were divided into three groups depending on the precast segments number. All had an identical total length of 3150mm but each had different segment number (9, 7, and 5 segments), in other words, different segment lengths. To simulate genuine fire disasters, the nine beams were exposed to high-temperature flames for one hour along with the control specimens. The selected temperatures were 300°C (572°F), 500°C (932°F), and 700°C (1292°F) as recommended by the standard fire curve (ASTM–E119). The specimens were cooled gradually at ambient laboratory conditions. The performance of the prestressed segmental concrete beams through the burning process was described with regard to the beams camber, spalling, and occurred deterioration.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 16 2017
Journal Name
Computers
Enhancing BER Performance Limit of BCH and RS Codes Using Multipath Diversity
...Show More Authors

View Publication
Scopus (13)
Crossref (9)
Scopus Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
THEORETICAL AND EXPERIMENTAL STUDY ON THERMAL PERFORMANCE OF CLOSED WET COOLING TOWER
...Show More Authors

Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Feb 28 2022
Journal Name
Journal Of Educational And Psychological Researches
Evaluating Supervision’s Performance of Specialist Supervisors in Secondary Schools from Principals’ Perspectives
...Show More Authors

The objective of the research is to identify the level of supervisory performance of the educational supervisor from the point of view of headmasters at secondary schools. The problem was the need to evaluate performance. A sample of (97) school headmasters was chosen to collect the needed data, they proportionated (38%) of the total community. the researcher designed a questionnaire consisted of (43) paragraphs with five areas. The results showed that there is a good level of performance among supervisors; there are no significant differences in the variable of the certificate, while there were significant differences in terms of gender for the benefit of males. The research concluded with a number of recommendations and suggestions.

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 01 2022
Journal Name
Journal Of Engineering
Performance Evaluation the Turbidity Removal Efficiency of AL-Muthana Water Treatment Plant
...Show More Authors

Turbidity is a visual property of water that expresses the amount of suspended substances in the water. Its presence in quantities more significant than the permissible limit makes the water undrinkable and reduces the effectiveness of disinfectants in treating pathogens. On this basis, turbidity is used as a basic indicator for measuring water quality. This study aims to evaluate the removal efficiency of AL- Muthanna WTP. Water turbidity was used as a basic parameter in the evaluation, using performance improvement evaluation and data from previous years (2016 to 2020). The average raw water turbidity was 26.7 NTU, with a minimum of 14 NTU, with a maximum of 48 NTU. Water turbidity value for 95% of settling daily reading data was

... Show More
Crossref (5)
Crossref
Publication Date
Wed Feb 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Performance Evaluation Strategy and its Impact on the Achievement of Organizational Effectiveness
...Show More Authors

Abstract

The research aims to determine the impact of the strategy performance evaluation and of the Standards (leadership, people, knowledge, processes, financial) in the achievement of organizational effectiveness in accordance with the dimensions (planning and setting goals, Exploitation of the Environment, achieve the goals, the ability to adapt, information management and communications) and the relationship between them, the problem of the research in the growing interest in the process of performance evaluation for organizations, the erroneous belief that the performance evaluation activity is useful, and the fact that performance evaluation process is one of the main tasks of the work of the Office of the Inspecto

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Nov 03 2021
Journal Name
International Journal Of Energy Research
Simulation and experimentation study on the performance of metal hydride storage vessels
...Show More Authors

This paper details the process of designing, analysing, manufacturing, and testing an integrated solid-state hydrogen storage system. Analysis is performed to optimise flow distribution and pressure drop through the channels, and experimental investigations compare the effects of profile shape on the overall power output from the fuel cell. The storing of hydrogen is given much attention in the selection of a storage medium, and the effect of a cooling system to reduce the recharging time of the hydrogen storage vessel. The PTFE seal performed excellently, holding pressure over 60 bar, despite requiring changing each time the cell is opened. The assembly of the vessel was simple and straightforward, and there was no indication of pressure

... Show More
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Sep 01 2010
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Surface Roughness on Thermohydrodynamic Performance in Misaligned Journal Bearings
...Show More Authors

     In this work an approach has been developed to investigate the influence of surface roughness on thermohydrodynamic performance in aligned and misaligned journal bearings by considering an average flow model and deriving the shear flow factor for various roughness configurations, similar to the pressure flow factor. An average Reynolds equation for rough surfaces is defined in term of pressure and shear flow factors, which can be obtained by numerical flow simulation, though the use of measured or numerically generated rough surfaces. Reynolds, heat conduction and energy equations are solved simultaneously by using a suitable numerical technique (Finite Difference Method) to obtain the pressure and temperature di

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
Photocatalytic Performance of AgNPs-Zeolite Composite by Hydrothermal Synthesis for Water Splitting
...Show More Authors

Two samples of (Ag NPs-zeolite) nanocomposite thin films have been prepared by easy hydrothermal method for 4 hours and 8 hours inside the hydrothermal autoclave at temperatures of 100°C. The two samples were used in a photoelectrochemical cell as a photocatalyst inside a cell consisting of three electrodes: the working electrode photoanode (AgNPs-zeolite), platinum as a cathode electrode, and Ag/AgCl as a reference electrode, to study the performance of AgNPs-zeolite under dark current and 473 nm laser light for water splitting. The results show the high performance of an eight-hour sample with high crystallinity compared with a four-hour sample as a reliable photocatalyst to generate hydrogen for renewable energies.

 

View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Performance evaluation of sewage treatment plant for Abu Ghraib Dairy Factory, Iraq
...Show More Authors

The objective of this study is to verify the overall performance and evaluate the wastewater quality of the wastewater treatment plant at the Abu Ghraib Dairy Factory and compare the results with the Iraqi Quality Standards (IQS) for effluent disposal and with the national determinants of treated water use. Agricultural irrigation wastewater, which included daily assessment records of the main parameters affecting wastewater [five-day biochemical oxygen demand (BOD5), chemical oxygen demand (COD), total dissolved solids (T.D.S), total suspended solids (TSS), phosphate (PO4), nitrate (NO3), hydrogen ion concentration (pH)] obtained from the quality control department of Abu Ghraib dairy plant registered from January 2017 to December 2020. Th

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Dec 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Standards Evaluate The Performance of Emergency Departments In Iraqi Hospitals / Case Study
...Show More Authors

     This study aims to evaluate the performance of emergency departments according to international standards through studying the performance in some of Iraqi public hospitals, where the evaluation performance is considered one of the important topics that take a great deal of officials' attention, especially decision makers in health organizations.

      The researcher has derived the research idea from the importance of work in emergency department in hospitals and to what it provides of medical services and quick and immediate nursing care that help in patients' lifesaving, and it is the mirror that reflects the real image for the hospital

... Show More
View Publication Preview PDF
Crossref