Preferred Language
Articles
/
zRd_opEBVTCNdQwCa5YY
Study the Effect of Irradiation Time and HF Concentration on Porosity of Porous Silicon and Study Some of the Electrical Properties of Its Based Device
...Show More Authors

ABSTRACT Porous silicon has been produced in this work by photochemical etching process (PC). The irradiation has been achieved using ordinary light source (150250 W) power and (875 nm) wavelength. The influence of various irradiation times and HF concentration on porosity of PSi material was investigated by depending on gravimetric measurements. The I-V and C-V characteristics for CdS/PSi structure have been investigated in this work too.

Crossref
Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 03 2017
Journal Name
Baghdad Science Journal
Biological control of saw toothed beetle Oryzaephilus surinamensis(L.)Using fungi Lecanicillium lecanii(Zimm.)
...Show More Authors

This study is conducted to determine the effect of pathogenicity of the fungus Lecanicillium lecanii in some aspects of life of the insect saw toothed beetle Oryzaephilus surinamensis L. (Coleoptera: Silvanidae) under laboratory conditions with three concentrations of spores and mildew commentator (1 × 103, 1 × 105, 1 × 107) spore / ml , on eggs and larvae second phase of the insect .The study also includs the effect of the fungus concentrations of germination on rice (jasmine) by using direct spray treatment. The results show great fungus efficiency in the control of some aspects of life of the insect, where varied efficiency depends on the concentration of spores, The highest percentage loss of eggs is 63.33% at a concentration

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
One dimensional Finite Element Solution of Moving Boundaries in Far IR Laser Tissue Ablation
...Show More Authors

In this work, the finite element analysis of moving coordinates has been used to study the thermal behavior of the tissue subjected to both continuous wave and pulsed CO2 laser. The results are compared with previously published data, and a good agreement has been found, which verifies the implemented theory. Some conclusions are obtained; As pulse width decreases, or repetition rate increases, or fluence increases then the char depth is decreased which can be explained by an increase in induced energy or its rate, which increases the ablation rate, leading to a decrease in char depth. Thus: An increase in the fluence or decreasing pulse width or increasing repetition rate will increase ablation rate, which will increase the depth of cut

... Show More
View Publication Preview PDF
Publication Date
Tue Nov 01 2022
Journal Name
Energy Reports
Thermal effectiveness of solar collector using Graphene nanostructures suspended in ethylene glycol–water mixtures
...Show More Authors

View Publication
Scopus (20)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Fri May 01 2020
Journal Name
Environmental Technology & Innovation
Environmental remediation of synthetic leachate produced from sanitary landfills using low-cost composite sorbent
...Show More Authors

Scopus (36)
Crossref (31)
Scopus Clarivate Crossref
Publication Date
Wed Dec 12 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Impact of Instructional Intervention about Personal Hygiene upon Women who complain Pelvic Inflammatory Disease
...Show More Authors

Objective: To determine the impact of personal hygiene on woman who complain pelvic inflammatory disease Methodology: A quasi experimental study in the High Institute Infertility Diagnostic and A.R.T.(assistance reproductive technology) in AL-Kadimya city and al-Emamian al Kadmain medical city hospital. The sample collected during (26th ) January – (30th ) April 2014. A purposive sample of (60) women, (30) of them regard as study group and (30) regard as a control group whom they take routine care in the institute and hospital. The questionnaire consisted of socio-demographic data, reproductive heal

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 01 2016
Journal Name
Journal Of Engineering
Non-Destructive Testing of Carbon Fiber Reinforced Magnetic Reactive Powder Concrete Containing Nano Silica
...Show More Authors

This study involves the design of 24 mixtures of fiber reinforced magnetic reactive powder concrete containing nano Silica. Tap water has been used in mixing 12 of these mixtures, while the other 12 have been mixed using magnetic water. Nano Silica (NS) with ratios (1, 1.5, 2, 2.5 and 3) % were used. The results showed that the mixture containing 2.5%NS gives the highest compressive strength at age 7 days. Many different other tests were carried out, the results showed that the fiber reinforced magnetic reactive powder concrete containing 2.5% NS (FRMRPCCNS)  has the higher bulk density, dynamic modulus of elasticity, ultrasonic pulse velocity  electrical resistivity and lesser absorption than fiber reinforced

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
Amplified Spontaneous Emission of DCM Dye in PMMA Polymer Using Copper Metal Disks Mold
...Show More Authors

The effect of irradiation and exposure time of laser light on the fluorescence emission of DCM dye in PMMA polymer contained in the composition mold using different metals have been investigated. It was found that the fluorescence intensity decreases as the exposure time increases and then reaches stabilization at long times. The effect of the incident laser power on fluorescence intensity of DCM dye in PMMA polymer at 10-3 M and 20% mixing ratio, using copper disks of composition molds, has been studied too. It was observed that there is an upward knick in the curve at laser intensity of 19.2 W/cm2, which may be associated with the threshold for amplified spontaneous emission (ASE) or laser action. And at intensity higher than about 88.

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Enhancement of Episiotomy Healing Using (790-805) nm Diode Laser as a Supplementary Treatment
...Show More Authors

To show the impact of 790-805 nm diode laser irradiations on wound healing as a supplementary treatment in women underwent episiotomies, and to assess the laser parameters that were used .Material and methods: Eighteen female patients were included in this study; all of them underwent mediolateral episiotomy. Ten patients received laser therapy- diode laser (K Laser) (790-805) nm in CW mode of operation (and eight patients were the control group. Spot size of 8mm, time for exposure for each spot was 30 seconds. The power used was 0.6 W .The power density for each spot of treatment was 1.19 W/cm2 per session (non contact mode of application of laser therapy).The group studied received 2 sessions of laser radiation, day 4, and day 8 after

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 07 2013
Journal Name
Journal Of Educational And Psychological Researches
Effectiveness of enrichment activities through using software program for second graders in Conversation article
...Show More Authors

Today we are witnessing huge scientific and technical progress so we need more skills and methods of thinking that needs to be acquired by the teacher, as the importance of computers in education  there are  many teachers  suffering  of the difficulty in teaching for pupils . researchers tried to  find a good suitable way with the technological  interests for now which represent by  computer design software and the introduction of enrichment activities in the curriculum because it is one of a contemporary trends for the development of the Arabic language with various levels of education and knowing if this program has negative or positive impact.

So&nbsp

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Experimental Performance of a Finned-tube Silica Gel Adsorption Chiller for Air-Conditioning Application
...Show More Authors

This work presents the construction of a test apparatus for air-conditioning application that is flexible in changing a scaled down adsorbent bed modules. To improve the heat and mass transfer performance of the adsorbent bed, a finned-tube of the adsorbent bed heat exchanger was used. The results show that the specific cooling power (SCP) and the coefficient of performance (COP) are 163 W/kg and 0.16, respectively, when the cycle time is 40 min, the hot water temperature is 90oC, the cooling water temperature is 30oC and the evaporative water temperature is 11.4oC.

View Publication Preview PDF