Preferred Language
Articles
/
zBYYsIsBVTCNdQwCB9YL
Determine, Predict and Map Soil pH Level by Fiber Optic Sensor
...Show More Authors
Abstract<p>Soil pH is one of the main factors to consider before undertaking any agricultural operation. Methods for measuring soil pH vary, but all traditional methods require time, effort, and expertise. This study aimed to determine, predict, and map the spatial distribution of soil pH based on data taken from 50 sites using the Kriging geostatistical tool in ArcGIS as a first step. In the second step, the Support Vector Machines (SVM) machine learning algorithm was used to predict the soil pH based on the CIE-L*a*b values taken from the optical fiber sensor. The standard deviation of the soil pH values was 0.42, which indicates a more reliable measurement and the data distribution is normal. The Kriging method gave a prediction accuracy of 65% while the SVM algorithm gave an accuracy of 80%. The root mean square error (RMSE) was 0.36, 0.16 and the mean absolute error (MAE) was 0.37, 0.13, respectively, for the two methods. These two methods allow the prediction of soil pH and thus the assessment of soils, allowing for easier and more efficient management decisions and sustaining productivity.</p>
Scopus Crossref
View Publication
Publication Date
Mon Jul 01 2019
Journal Name
Journal Of Physics: Conference Series
Effect of Nickel Substitution On Structural and Electrical Properties of Hg<sub>0.5</sub>Pb<sub>0.5</sub>Ba<sub>2</sub>Ca<sub>2</sub>Cu<sub>3-y</sub>Ni<sub>y</sub>O<sub>8+δ</sub> Superconductor Composite
...Show More Authors
Abstract<p>six specimens of the Hg<sub>0.5</sub>Pb<sub>0.5</sub>Ba<sub>2</sub>Ca<sub>2</sub>Cu<sub>3-y</sub> <italic>Ni<sub>y</sub> </italic>O<sub>8+δ</sub> (y=0.2,0.4,0.6,0.8,1.0) superconducting compound were prepared by solid state reaction method, with sintering temperature equal to 1123K for 24 hours. The electrical resistivity was examined by the four probe technique, It was found that all the specimens have metallic behavior and increasing the critical temperature with increasing nickel concentration. The optimum critical temperature T<sub>c</sub> was found equal </p> ... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Study affects Pulse Parameters versus cavity length for both Dispersion Regimes in FM mode locked.: Bushra.R.Mhdi|Gaillan H.Abdullah|Mohand M.Azzawi|Nahla.A.Hessin|Basher.R.Mhdi
...Show More Authors

To demonstrate the effect of changing cavity length for FM mode locked on pulse parameters and make comparison for both dispersion regime , a plot for each pulse parameter as Lr function are presented for normal and anomalous dispersion regimes . The analysis is based on the theoretical study and the results of numerical simulation using MATLAB. The effect of both normal and anomalous dispersion regimes on output pulses is investigate Fiber length effects on pulse parameters are investigated by driving the modulator into different values. A numerical solution for model equations using fourth-fifth order, Runge-Kutta method is performed through MATLAB 7.0 program. Fiber length effect on pulse parameters is investigated by driving th

... Show More
View Publication
Crossref
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Design of Tunable Optical Band Pass Filter based on in-Line PM-Mach Zehnder Interferometer
...Show More Authors

In this paper, tunable optical band-pass filters based on Polarization Maintaining Fiber –Mach Zehnder Interferometer presented. Tunability of the band-pass filter implemented by applying different mechanical forces N on the micro-cavities splicing regions (MCSRs). The micro-cavity formed by using three variable-lengths of single-mode polarization-maintaining fiber with (8, 16, 24) cm lengths, splice between two segments of (SMF-28) with (26, 13) cm lengths, using the fusion splicing technique.  Ellipsoidal shape micro-cavities experimentally achieved parallel to the propagation axis having dimensions between (12-24) μm of width and   (4-12) μm of length. A micro-cavity with width and length as high as 24 μm and 12 μ

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Measuring Dyes Concentration Using a Low-Cost Visible-Light Spectrophotometer
...Show More Authors

   A low-cost, RGB LED-based visible-light spectrophotometer was designed to measure dyes concentration. Dyes are widely used as indicators or coloring agents in different applications and knowing their concentration is an essential part for many studies. The proposed spectrophotometer provides many functionalities that clones the traditional expensive spectrophotometers for a budged price under $50. It was aimed to provide a versatile tool for instructors and educators to teach their students the fundamental concepts behind spectrophotometry. Malachite green, methyl red, and methyl orange dyes were chosen to be good samples to show the integrity of the proposed spectrophotometer in terms of accuracy, repeatability, and sensitivity as

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jul 29 2020
Journal Name
Iraqi Journal Of Science
Laser Distance Sensors Evaluation for Geomatics Researches
...Show More Authors

In this study, an approach inspired by a standardized calibration method was used to test a laser distance meter (LDM). A laser distance sensor (LDS) was tested with respect to an LDM and then a statistical indicator explained that the former functions in a similar manner as the latter. Also, regression terms were used to estimate the additive error and scale the correction of the sensors. The specified distance was divided into several parts with percent of longest one and observed using two sensors, left and right. These sensors were evaluated by using the regression between the measured and the reference values. The results were computed using MINITAB 17 package software and excel office package. The accuracy of the results in this wo

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Thu Dec 28 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Synthesis and Characterization of some Metal Complexes with (3Z ,5Z, 8Z)-2-azido-8-[azido(3Z,5Z)-2-azido-2,6bis(azidocarbonyl)-8,9-dihydro-2H-1,7-dioxa-3,4,5triazonine-9-yl]methyl]-9-[(1-azido-1-hydroxy)methyl]-2H1,7-dioxa-3,4,5-triazonine – 2,6 – dica
...Show More Authors

  The reaction of LAs-Cl8 : [ (2,2- (1-(3,4-bis(carboxylicdichloromethoxy)-5-oxo-2,5dihydrofuran-2-yl)ethane – 1,2-diyl)bis(2,2-dichloroacetic acid)]with sodium azide in ethanol with drops of distilled water has been investigated . The new product L-AZ :(3Z ,5Z,8Z)-2azido-8-[azido(3Z,5Z)-2-azido-2,6-bis(azidocarbonyl)-8,9-dihydro-2H-1,7-dioxa-3,4,5triazonine-9-yl]methyl]-9-[(1-azido-1-hydroxy)methyl]-2H-1,7-dioxa-3,4,5-triazonine – 2,6 – dicarbonylazide was isolated and characterized by elemental analysis (C.H.N) , 1H-NMR , Mass spectrum and Fourier transform infrared spectrophotometer (FT-IR) . The reaction of the L-AZ withM+n: [ ( VO(II) , Cr(III)  ,Mn(II) , Co(II) , Ni(II) , Cu(II) , Zn(II) , Cd(II) and

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Oct 03 2020
Journal Name
International Journal Of Diabetes In Developing Countries
The efficacy of once-daily liraglutide as an add-on to oral antidiabetic agents on weight reduction and glycemic control in obese patients with inadequately controlled type 2 diabetes: a retrospective analysis in relation to liraglutide dose escalation within a 7-month treatment period
...Show More Authors

Background This study aimed to evaluate the efficacy of once-daily liraglutide as an add-on to oral antidiabetics (OADs) on glycemic control and body weight in obese patients with inadequately controlled type 2 diabetes (T2D). Methods A total of 27 obese T2D patients who received 7 months (0.6 mg/day for the first month, 1.2 mg/day for 3 months, and 1.8 mg/day for 3 months) of liraglutide treatment as an add-on to OADs were included. Data on body weight (kg), fasting plasma glucose (FPG, mg/dL), postprandial glucose (PPG, mg/dL), and HbA1c (%), were recorded. Results Liraglutide doses of 1.2 mg/day and 1.8 mg/day were associated with significant decreases in body weight (by 8.0% and 11.9%, respectively, p < 0.01 for each) and HbA1c (by 20.0

... Show More
Preview PDF
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Manufacturing and studying the effect of partial substitution on the properties of the compound Bi<sub>2-x</sub> Ag<sub>x</sub>Sr<sub>1.9</sub>Ba<sub>0.1</sub>Ca<sub>2</sub>Cu<sub>3</sub>O<sub>10+δ</sub> superconductors.
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Feb 21 2025
Journal Name
Al–bahith Al–a'alami
THE ISSUES OF YOUTH IN THE TALK SHOWS IN THE IRAQI SATELLITE CHANNELS:: (An Analytical Study of the Shabab wa Banat Program at Al-Sumaria TV Channel and of the Hala Shabab at Al-Iraqia TV Channel) (A Research Drawn from a Master’s Thesis)
...Show More Authors

The purpose of this research is to identify the youth issues in Talk Shows in the Iraqi satellite channels via monitoring a sample of episodes of the Talk Shows  episodes which are concerned and analyzed the youth issues in the Iraqi satellite channels, namely, «Hala Shabab Program» at Al-Iraqia satellite Channel and «Shabab wa Banat Program» at Al-Sumaria satellite Channel by recording and re-watching them again. This research is classified as one of descriptive researches. The survey method was adopted in this study.

For this purpose, the researcher prepared an analysis form. The researcher de

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Iraqi Journal Of Science
Natural radioactivity Measurements of Dur-Kurigalzu's Ziggurat, Baghdad Governorate-Iraq using HPGe detector
...Show More Authors

       Measurement of 238U, 233Th and 40K concentrations in soil samples collected from Ziggurat of Dur-Kurigalzu west region of Baghdad, have been evaluated, using high purity germanium detector. The activity concentrations of 238U, 233Th and 40K varied from 16.040  to 26.620 , 14.510  to 31.480 , and 153.820  to 266.320  with average values of 20.604±2.9 , 24.534±3.3 , 212.22±25.1 , respectively. The importance of these measurements lies in the estimation of radiation risk, radium equivalent, absorbed dose, annual effective dose, risk indices, gamma index, and cancer risk. The average value of the absorbed dose ranged from 33.187  outdoors to 63.111  indoo

... Show More
View Publication Preview PDF
Scopus Crossref