Stereolithography (SLA) has become an essential photocuring 3D printing process for producing parts of complex shapes from photosensitive resin exposed to UV light. The selection of the best printing parameters for good accuracy and surface quality can be further complicated by the geometric complexity of the models. This work introduces multiobjective optimization of SLA printing of 3D dental bridges based on simple CAD objects. The effect of the best combination of a low-cost resin 3D printer’s machine parameter settings, namely normal exposure time, bottom exposure time and bottom layers for less dimensional deviation and surface roughness, was studied. A multiobjective optimization method was utilized, combining the Taguchi method with response surface methodology and the desirability function technique. The predicted optimal values for the cube’s dimensional deviation and surface roughness were 0.0517 mm and 2.8079 µm, respectively. The experiments’ validation of the findings confirmed the results, which were determined to be 0.0560 and 0.064667 mm and 2.770 and 2.6431 µm for the dimensional deviation and surface roughness for the cube and bridge, respectively. The percentages of prediction errors between the predicted optimum results and the printed response were 7.68% and 1.36% for dimensional deviation and surface roughness, respectively. This study demonstrates that the robust method used produced a dental bridge with good accuracy and a smooth surface.
The linear segment with parabolic blend (LSPB) trajectory deviates from the specified waypoints. It is restricted to that the acceleration must be sufficiently high. In this work, it is proposed to engage modified LSPB trajectory with particle swarm optimization (PSO) so as to create through points on the trajectory. The assumption of normal LSPB method that parabolic part is centered in time around waypoints is replaced by proposed coefficients for calculating the time duration of the linear part. These coefficients are functions of velocities between through points. The velocities are obtained by PSO so as to force the LSPB trajectory passing exactly through the specified path points. Also, relations for velocity correction and exact v
... Show MoreSteganography is the art of concealing security data in media, such as pictures, audio, video, text, and protocols. The objective of this paper is hiding a secret message in a colour image to prevent an attacker from accessing the message. This is important because more people use the Internet all the time and network connections are spread around the world. The hidden secret message uses two general algorithms that are embedded and extracted. This paper proposes a new algorithm to conceal a secret message in a colour image in LSB. This algorithm includes three phases: 1) dividing the colour image into a number of blocks, 2) concealing the secret message, and 3) transmitting the stego-image from the sender in a multiplexer network and re
... Show MoreThe study aimed to compare the expression of miR-126-3p and miR-423-5p in patients and normal subjects, and correlate their expression with response to induction therapy. Circulating miR-126-3p and miR-423-5p were measured in the plasma of 43 adult AML patients and 35 age- and sex-matched controls by real time PCR. The foldchange in differential expression for each gene was calculated using the comparative cycle threshold (CT) method (also known as the 2−CT method). For statistical purposes, the fold change was calculated using DDCT (or 2–∆∆Ct) method to find the relative expression of miRNAs. The expression fold change of miR-126-3p was 1.73-fold increase in patients than controls (p= 0.010). The expression fold change of miR-423-5
... Show MoreIn this research, a mathematical model of tumor treatment by radiotherapy is studied and a new modification for the model is proposed as well as introducing the check for the suggested modification. Also the stability of the modified model is analyzed in the last section.
This paper deals with the design and implementation of an ECG system. The proposed system gives a new concept of ECG signal manipulation, storing, and editing. It consists mainly of hardware circuits and the related software. The hardware includes the circuits of ECG signals capturing, and system interfaces. The software is written using Visual Basic languages, to perform the task of identification of the ECG signal. The main advantage of the system is to provide a reported ECG recording on a personal computer, so that it can be stored and processed at any time as required. This system was tested for different ECG signals, some of them are abnormal and the other is normal, and the results show that the system has a good quality of diagno
... Show MoreThe present work investigates the effect of magneto – hydrodynamic (MHD) laminar natural convection flow on a vertical cylinder in presence of heat generation and radiation. The governing equations which used are Continuity, Momentum and Energy equations. These equations are transformed to dimensionless equations using Vorticity-Stream Function method and the resulting nonlinear system
of partial differential equations are then solved numerically using finite difference approximation. A thermal boundary condition of a constant wall temperature is considered. A computer program (Fortran 90) was built to calculate the rate of heat transfer in terms of local Nusselt number, total mean Nusselt number, velocity distribution as well as te
The solar radiation plays an important role on the energy balance of the earthatmosphere, which is the main source of energy. Also the solar radiation is a main factor of all applications which use a solar energy as renewable energy source. The purpose of this research is to study the monthly average changes for solar radiation for the period from 1985 to 1989 by using satellite Antenna Alignment from (NASA). The result shows that the monthly average radiation changes from one year to another because of the changing of it component of atmosphere, (gases, clouds and Aerosols) and as an enhancement for this conclusion, we compared the results with the monthly average radiation at clear atmosphere where the change was slig
... Show More