Background: Dysfunction of sinoatrial node is a set of abnormal rhythms which are resulted from the sinoatrial node malfunctionof the sinus node, the chief natural cardiac pacemaker. The common, and occasionally, the single method for treatment of heart arrhythmias wasimplantation of pacemaker, which reduce symptoms exactly occurs after implantation. Aim: To detect the association between red cell width diameter (RDW) and some cardiac electrophysiology parameters in sinus node dysfunction in Iraqi patients such as SNRT and AH. Methods: A cross sectional study, was conducted on 59 patient ranging between 20-50 years old and involving 35 female and 24 male patients, suffering from an unexplained symptoms of sinoatrial node dysfunction (SND). The enrolled participants were gathered from patients who visited the arrhythmia consultant clinic in the Najaf center for cardiac surgery and interventional catheterization at Al-Sadr Medical City in Najaf from all parts of Iraq. The duration of study extended from the beginning of July 2018 till the ending of July 2019. The patients were selected and investigated according to inclusion criteria and either referred to electrophysiological study. Results: The basic procedure of the study was measurement of cardiac electrophysiological parameters such as SNRT and AH as well as other noninvasive investigations such as PR. Depending on sinus node recovery time (SNRT) measurement for all patients, new cutoff point (1150 milliseconds) for pacemaker implantation was detected. Statistically significant correlations were found between new SNRT cutoff of study and most of electrophysiological, anthropometric, demographic that achieved in current study (P-value< 0.05). Conclusion: RDW has a significant effecton PR, SNRT, and AH parameters of patients with unexplained symptomatic SND in Iraq. © 2020 Lahore Medical And Dental College. All rights reserved.
A specialized irradiation instrument "created instrument" was designed and created from various kinds and sizes of available plastic household-waste materials. In addition, a neutron beam collimator with a lid was designed and implemented. The collimator is with dimensions of 25 cm in height and 10 cm in inner diameter, while the lid dimensions are 11.5 cm height and outer diameter of 9.9 cm to perfectly match the inner diameter of the collimator with the possibility of movement (opening and closing), and also the shielding of the radioactive 241Am/Be neutron source with a recent activity of 37.5 mCi.
To investigate the efficiency of the "created instrument", ten hydrogenous material samples (ordinary p
... Show MoreThe production companies in the Iraqi industry environment facing many of the problems related to the management of inventory and control In particular in determining the quantities inventory that should be hold it. Because these companies adoption on personal experience and some simple mathematical methods which lead to the identification of inappropriate quantities of inventory.
This research aims to identify the economic quantity of production and purchase for the Pepsi can 330ml and essential components in Baghdad soft drinks Company in an environment dominated by cases of non ensure and High fluctuating as a result of fluctuating demand volumes and costs ass
... Show More