Background: Preterm labor and related prematurity are predisposing factors that increase perinatal morbidity and mortality. Acute phase reactants are inflammatory markers which are positive and negative reactants explained by the reaction of reactants to the subclinical infection that are commonly associated with preterm labor. Objectives: To assess the role of acute phase reactants in pregnant women with preterm delivery. Patients and method: A case control study conducted in Gynecological Department of Baghdad Teaching Hospital from 1st February 2021 to 30th October 2021, on one hundred pregnant women with gestational age (28weeks - 36weeks+6days) who attended outpatient clinic; fifty pregnant women with established preterm labor as case group and fifty pregnant women with no signs and symptoms of preterm labor as control group. Data was collected using structured questionnaire included demographic features, and biochemical parameters (serum ferritin (ng/ml), albumin (gm/dl), fibrinogen (mg/dl), and calcium (mg/dl) . Results: Mean±SD serum ferritin in control group was (46.2 ± 16.2 ng/ml) while in case group (52.47 ± 11.6ng/ml) with significant difference between both groups (P=0.03), mean±SD serum albumin in control group (3.18 ± 0.31 ng/ml) while in case group (2.92 ± 0.39) with highly significant difference between both groups (P<0.001). Validity test of serum ferritin at cutoff ≥ 52.7 (ng/ml) in case group was as follows: Sensitivity (94%), specificity (90%), negative predictive value (94%), positive predictive value (90%) and the accuracy was (92%). The validity test of serum albumin at cutoff ≤ 3.06 (gm/dl) to detect the preterm labor as follows: Sensitivity (78%), specificity (86%), negative predictive value (78%), positive predictive value (83%) and the accuracy was (84%). Mean±SD serum fibrinogen in control group was (400.9 ± 38.1) while in case group was (410.7 ± 51.2) with no significant difference between both groups (P=0.1). Mean±SD serum calcium in control group was (8.1 ± 0.7) while in case group was (7.92 ± 0.5) with no significant difference between both groups (P=0.1). Conclusion: serum ferritin and albumin can be used in prediction of preterm labor in 3rd trimester.
Applying a well-performing heat exchanger is an efficient way to fortify the relatively low thermal response of phase-change materials (PCMs), which have broad application prospects in the fields of thermal management and energy storage. In this study, an improved PCM melting and solidification in corrugated (zigzag) plate heat exchanger are numerically examined compared with smooth (flat) plate heat exchanger in both horizontal and vertical positions. The effects of the channel width (0.5 W, W, and 2 W) and the airflow temperature (318 K, 323 K, and 328 K) are exclusively studied and reported. The results reveal the much better performance of the horizontal corrugated configuration compared with the smooth channel during both melti
... Show MoreGlobally, over forty million people are living with Human Immunodeficiency Viral (HIV) infections. Highly Active Antiretroviral Therapy (HAART) consists of two or three Antiretroviral (ARV) drugs and has been used for more than a decade to prolong the life of AIDS-diagnosed patients. The persistent use of HAART is essential for effectively suppressing HIV replication. Frequent use of multiple medications at relatively high dosages is a major reason for patient noncompliance and an obstacle to achieving efficient pharmacological treatment. Despite strict compliance with the HAART regimen, the eradication of HIV from the host remains unattainable. Anatomical and Intracellular viral reservo
A simple, environmental friendly and selective sample preparation technique employing porous membrane protected micro-solid phase extraction (μ-SPE) loaded with molecularly imprinted polymer (MIP) for the determination of ochratoxin A (OTA) is described. After the extraction, the analyte was desorbed using ultrasonication and was analyzed using high performance liquid chromatography. Under the optimized conditions, the detection limits of OTA for coffee, grape juice and urine were 0.06 ng g−1, 0.02 and 0.02 ng mL−1, respectively while the quantification limits were 0.19 ng g−1, 0.06 and 0.08 ng mL−1, respectively. The recoveries of OTA from coffee spiked at 1, 25 and 50 ng g−1, grape juice and urine samples at 1, 25 and 50 ng mL
... Show MoreThe aim of this work was to develop and validate a rapid and low cost method for estimation of ibuprofen in pharmaceutical suspensions using Reverse-Phase High Performance Liquid Chromatography. The proposed method was conducted and validated according to International Conference on Harmonization (ICH) requirements. The chromatographic parameters were as follows: column of octyldecylsilyl C18 with dimensions (150 × 4.6) mm, mobile phase composed of acetonitrile with phosphoric acid with a ratio of 50 to 50 each using isocratic mode, flow rate of 1.5 mL/min and injection volume of 5 μL. The detection was carried out using UV detector at 220 nm. The method was validated and showed short retention time for ibuprofen peak at 7.651 min, wit
... Show MoreBackground: Tubal ligation, recognized as a surgical intervention that ensures permanent contraception, has established itself as an option for women seeking a definitive solution for family planning. Objective: To assess the psychosexual implications of tubal ligation in a sample of women in Baghdad, Iraq. Methods: A prospective cohort study was conducted in a teaching hospital for 2 years, from the first of January 2022 to the end of December 2023, in which 203 women who underwent tubal ligation were included. Results: In the present study, we found that 158 (77.8%) had no depression, mild depression presented in 27 (13.3%), and moderate depression in only 15 (7.4%). While 163 (80.3%) of women did not suffer from anxiety, 32 (15.8
... Show MoreBackground: Acute appendicitis is regarded as one of the most common inflammation that needs surgical intervention. Different scoring systems have been used for diagnosing of acute appendicitis. ALVARADO score is one of the most widely used score in diagnosing of acute appendicitis, but the accuracy of the latter is insufficiently low in Middle-East patients. Thus a new scoring system called RIPASA score has been designed for diagnosing of acute appendicitis in those patients. The aim of this study is to use RIPASA score and compare its result with ALVARADO score in diagnosing of acute appendicitis.
Subjects and Methods: The study includes 200 patients with symptoms and signs of
... Show MoreThe study aims to identify the effects of dubbed Turkish drama on the public through the application of a sample of the views of women. The study also attempts to monitor the causes and motives due to the act of observation and to identify the various effects of this act. In order to achieve these goals, the researcher relies on the descriptive approach in addition to the questionnaire and interviews to collect data. It ends with a number of results such as: The study aims to identify the effects of dubbed Turkish drama on the public through the application of a sample of the views of women. The study also attempts to monitor the causes and motives due to the act of observation and to identify the various effects of this act. In ord
... Show MoreObjectives: To assess nurses-midwives knowledge and performance regarding immediate newborn care in delivery rooms, and to identify the relationship between nurses-midwives knowledge and performance and their socio-demographic and professional variables regarding immediate newborn care.
Methodology: A descriptive study was conducted from 1st of October, 2019 to 20TH of October, 2020 at three maternity teaching hospitals in Baghdad city/Al-Russafa Health Directorate: Al-Elwiya Maternity Teaching Hospital, Fatema Al- Zahra Maternity and Pediatric Hospital, Al- Za'faraniyah General Hospital. Non-probability (purposive sample) include
... Show More