Preferred Language
Articles
/
yobGQYYBIXToZYALF4DZ
Immiscible CO2-Assisted Gravity Drainage Process for Enhancing Oil Recovery in Bottom Water Drive reservoir
...Show More Authors

The CO2-Assisted Gravity Drainage process (GAGD) has been introduced to become one of the mostinfluential process to enhance oil recovery (EOR) methods in both secondary and tertiary recovery through immiscibleand miscible mode. Its advantages came from the ability of this process to provide gravity-stable oil displacement forenhancing oil recovery. Vertical injectors for CO2 gas have been placed at the crest of the pay zone to form a gas capwhich drain the oil towards the horizontal producing oil wells located above the oil-water-contact. The advantage ofhorizontal well is to provide big drainage area and small pressure drawdown due to the long penetration. Manysimulation and physical models of CO2-AGD process have been implemented at reservoir and ambient conditions tostudy the effect of this method to improve oil recovery and to examine the most parameters that control the CO2-AGDprocess. The CO2-AGD process has been developed and tested to increase oil recovery in reservoirs with bottom waterdrive and strong water coning tendencies. In this study, a scaled prototype 3D simulation model with bottom waterdrive was used for CO2-assisted gravity drainage. The CO2-AGD process performance was studied. Also the effects ofbottom water drive on the performance of immiscible CO2 assisted gravity drainage (enhanced oil recovery and watercut) was investigated. Four different statements scenarios through CO2-AGD process were implemented. Resultsrevealed that: ultimate oil recovery factor increases considerably when implemented CO2-AGD process (from 13.5%to 84.3%). Recovery factor rises with increasing the activity of bottom water drive (from 77.5% to 84.3%). Also,GAGD process provides better reservoir pressure maintenance to keep water cut near 0% limit until gas flood frontreaches the production well if the aquifer is active, and stays near 0% limit at all prediction period for limited waterdrive.

Publication Date
Mon Jul 01 2019
Journal Name
Iop Conference Series: Materials Science And Engineering
Influence of water in size of Synthesized Carbon Black Nanoparticles from Kerosene by Flame Method
...Show More Authors

View Publication
Scopus (4)
Scopus Crossref
Publication Date
Thu May 31 2012
Journal Name
Journal Of Baghdad College Dentistry
An evaluation of water absorption of Giomer in comparison to other resin-based restorative materials
...Show More Authors

Background: Polymeric composites have been widely used as dental restorative materials. A fundamental knowledge and understanding of the behavior of these materials in the oral cavity is essential to improve their properties and performance. The goal of this study was to measure water sorption of four composite resins containing different filler and resin matrix contents. Materials and method: Resin composite specimens giomer (Beautifil II) Filtek™ P90, Filtek™ Z350 XT, and Tetric N Ceram were prepared in a cylindrical mould of 3mm thickness and 6mm diameter (n=10) and light cured . All specimens placed in silica-gel desiccators at 37˚C for seven days, a constant weight was obtained. All samples were immersed in deionized distill

... Show More
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Bismuth(III) with Arsenazo(III) Reagent in Water samples and Veterinary Preparation
...Show More Authors

A simple , sensitive and accurate spectrophotometric method for the trace determination of bismuth (III) has been developed .This method is based on the reaction of bismuth (III) with arsenazo(III) in acid solution (pH=1.9) to form a blue water soluble complex which exhibits maximum absorption at 612nm .Beer's law is obeyed over the concentration range of 2-85 ?g bismuth (III) in a final volume of 20 mL( i.e. 0.1 – 4.25?g.mL-1) with a correlation coefficient of (0.9981) and molar absorptivity 1.9×104 L.mol-1.cm-1 . The limit of detection (LOD) and the limit of quantification (LOQ) are 0.0633 and 0.0847 ?g.mL-1 , respectively . Under optimum conditions,the stoichiometry of the reaction between bismuth (III) and arsenazo(III) r

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Int. J. Agricult. Stat. Sci.
STRAWBERRY CV. FESTIVAL GROWTH IN RESPONSES TO MAGNETIC WATER AND FOLIAR APPLICATION OF COCONUT EXTRACT
...Show More Authors

This study was carried out to study effect of magnetic water ( M0 and M) and different concentrations of coconut extract in Fragaria x ananassa (Duch) C.V Festival. The results showed significant differences in the plants treated with magnetic water ( 0.12 Tesla) and different concentrations of coconut extract C1 (0%), C2 (2.5%), C3 (5%), C4 (7.5%) and C5 (10%) in vegetative parameters as in leaf area and chlorophyll in treatment M0C3 was (53.72 Dcm2, 50.00), respectively, highest leaf number and plant dry weight in MC4 (12.77,14.22 gm), respectively. Results recorded significant differences in fruit parameters such as weight in MC1 (18.97 gm). The maximum fruit number was in MC3 (110), the greatest fruit size was in MC4 (15.78 cm3) and the

... Show More
View Publication
Scopus
Publication Date
Fri Apr 01 2016
Journal Name
Water
The Effect of UV and Combined Chlorine/UV Treatment on Coliphages in Drinking Water Disinfection
...Show More Authors

View Publication
Scopus (43)
Crossref (36)
Scopus Clarivate Crossref
Publication Date
Wed Jun 08 2022
Journal Name
Applied Sciences
Effect of Adjuvant, Concentration and Water Type on the Droplet Size Characteristics in Agricultural Nozzles
...Show More Authors

One of the goals of adding adjuvants to agricultural spray solutions is to enhance the droplet size characteristics of this spray. Droplet size, in turn, has an influence in the deposited spray quality, in addition to the drift and losses of spray to off-target places. The aim of this research was to evaluate the effect of adding adjuvants to two types of water from different sources on the droplet size characteristics. Two types of adjuvants were employed in the tests: the active substance content of the first adjuvant was a 50% aqueous solution of sodium salt of alkylbenzenesulfonic acid—10% (HY), whereas the second was from rapeseed oil (natural origin)—85% (OL). Both adjuvants were tested in two concentrations: the first was

... Show More
View Publication
Scopus (23)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Sun Dec 31 2000
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Adsorption of NO2/N2O4 into Water and Dilute Nitric Acid in a Double Stirrer Adsorber
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Sep 18 2024
Journal Name
مجلة العصر للعلوم الانسانية والاجتماع
Spatial Analysis of the Pollution of the Euphrates River Water in the Abu Ghraib District
...Show More Authors

The research investigates the physical characteristics of the Euphrates River water in the Abu Ghraib district, where the river flows southwest, demarcating it from Anbar Governorate. Geographically, the area lies between latitudes 33°8'40" - 33°15'23" N and longitudes 43°50'21" - 44°1'24" E. The study is based on fieldwork and laboratory analyses aimed at detecting pollution by analysing four physical parameters during summer and winter. These physical properties include water temperature, turbidity, dissolved solids, and electrical conductivity. To elucidate pollution levels, the study area was divided into ten sites along the river. By examining pollution indicators through samples taken from these sites and comparing them to

... Show More
View Publication
Crossref
Publication Date
Fri Mar 19 2021
Journal Name
Plant Archives 21 (1), 1463-1469‏
Effect of addition of organic fertilizer and rootstock in Lemon transplants exposed to water stress‏
...Show More Authors

Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
The effect of using magnetized water on the percentage of cement in the Concrete mixture
...Show More Authors

This research studied the effect of magnetized water in concrete preparation and its effect on the presenting of cement in concrete mixtures also to find the ability of reducing the amount of cement in preparing one cubic meter, this is not exceed than 10% in one mixture , The experiments showed the preparation of standard cubes from the concrete which was used two kind of water magnetized water which was prepared by passing the tap water through the systems of different magnetic strength in terms of (6000,9000) Gauss and the ordinary water . The velocity of water through the magnetic field, which gives us the highest value for the compressive strength, was up to 1m/sec. to determine the best magnetic intensity, we examined The comp

... Show More
View Publication Preview PDF
Crossref (1)
Crossref