A gantry robot is one of the most common types of industrial robots with linear movement. This type of robot is also known as a Cartesian or linear robot. It is an automated industrial system that moves along linear paths, enabling it to create a 3D envelope of the space in which it operates. A robot of this type has a standardised configuration process because it can have several sets of axes, such as X, Y and Z. The gantry robot picks up products from several places, so it can search through various locations. Afterwards, it carefully deposits the products on a conveyor belt for the next stage of the procedure or final shipment. This integration enables continuous and automated material flow, increasing overall productivity and efficiency in manufacturing operations. Dimension measuring and object placement are critical tasks in robot and conveyor systems that depend substantially on the types of sensors. Progress in sensors and camera technologies has markedly enhanced precision, efficacy, productivity and adaptability. Sensors are commonly classified as range and vision sensors on the basis of their mode of measurement. This review article offers useful knowledge on gantry robots and conveyor systems and their historical background. It examines recent research that has reported on the advantages and disadvantages of gantry robots. Moreover, literature on object dimensioning and positioning via sensors and cameras in gantry robots is presented. This review elucidates the advantages and disadvantages of several sensing types, including cameras and conventional sensors. Comparisons of robotic systems in terms of accuracy, speed, cost, energy efficiency and other aspects are also performed. Many studies have been conducted on body detection via vision technology and sensors, but the use of laser sensors has received minimal attention and needs further focus in the future.
2,2'-(1-(3,4-bis(carboxydichloromethoxy)-5-oxo-2,5-dihydrofuran-2-yl)ethane-1,2-diyl)bis(oxy)bis(2,2-dichloroacetic acid) a derivative of L-ascorbic acid was prepared by reaction of L-ascorbic acid with trichloroacetic acid (1:4) ratio, in the presence of potassium hydroxide. A series of new metal complexes of this ligand were prepared by a reaction with the chlorides of Cd(II), Co(II), Ni(II), Cu(II) and Zn(II). The new ligand and its complexes were identified by C.H.N., IR, UV-visible spectra, Thermogravimetric analysis (TGA), as well as 1H, 13C-NMR and Mass spectra for ligand L. The complexes were also identified by molar conductance, atomic absorption, magnetic susceptibility and X-ray diffraction for Cu (II) complex. FT-IR spectra
... Show MorePurpose: We report a series of 29 pediatric patients who sustained head injuries due to metallic ceiling fans. They all were admitted to the Emergency Department of Neurosurgery Teaching Hospital in Baghdad, Iraq, during January 2015 to January 2017. Results: Pediatric ceiling fan head injuries are characterized by four traits which distinguish them from other types of head injuries; 1- Most of them were because of climbing on or jumping from furniture between the ages of two and five. 2- Most of them sustained compound depressed skull fracture which associated with intracranial lesions and pneumocephalus. 3- The most common indication for surgical intervention was because of dirty wound which mixed with hairs. 4- These variables were stati
... Show MoreThe challenge in studying fusion reaction when the projectile is neutron or proton rich halo nuclei is the coupling mechanism between the elastic and the breakup channel, therefore the motivation from the present calculations is to estimate the best coupling parameter to introduce the effect of coupled-channels for the calculations of the total cross section of the fusion , the barrier distribution of the fusion and the average angular momentum 〈L〉 for the systems 6He+206Pb, 8B+28Si, 11Be+209Bi, 17F+208Pb, 6He+238U, 8He+197Au and 15C+232Th using quantum mechanical approach. A quantum Coupled-Channel Calculations are performed using CC code. The predictions of quantum mechanical approach are comparable with the measured data that is
... Show MoreA study to find the optimum separators pressures of separation stations has been performed. Stage separation of oil and gas is accomplished with a series of separators operating at sequentially reduced pressures. Liquid is discharged from a higher-pressure separator into the lower-pressure separator. The set of working separator pressures that yields maximum recovery of liquid hydrocarbon from the well fluid is the optimum set of pressures, which is the target of this work.
A computer model is used to find the optimum separator pressures. The model employs the Peng-Robinson equation of state (Peng and Robinson 1976) for volatile oil. The application of t
In this research a new system identification algorithm is presented for obtaining an optimal set of mathematical models for system with perturbed coefficients, then this algorithm is applied practically by an “On Line System Identification Circuit”, based on real time speed response data of a permanent magnet DC motor. Such set of mathematical models represents the physical plant against all variation which may exist in its parameters, and forms a strong mathematical foundation for stability and performance analysis in control theory problems.
The challenge in studying fusion reaction when the projectile is neutron or proton rich halo nuclei is the coupling mechanism between the elastic and the breakup channel, therefore the motivation from the present calculations is to estimate the best coupling parameter to introduce the effect of coupled-channels for the calculations of the total cross section of the fusion , the barrier distribution of the fusion and the average angular momentum 〈L〉 for the systems 6He+206Pb, 8B+28Si, 11Be+209Bi, 17F+208Pb, 6He+238U, 8He+197Au and 15C+232Th using quantum mechanical approach. A
... Show MoreThe monitoring weld quality is increasingly important because great financial savings are possible because of it, and this especially happens in manufacturing where defective welds lead to losses in production and necessitate time consuming and expensive repair. This research deals with the monitoring and controllability of the fusion arc welding process using Artificial Neural Network (ANN) model. The effect of weld parameters on the weld quality was studied by implementing the experimental results obtained from welding a non-Galvanized steel plate ASTM BN 1323 of 6 mm thickness in different weld parameters (current, voltage, and travel speed) monitored by electronic systems that are followed by destructive (Tensile and Bending) and non
... Show MoreA simple ,accurate and sensitive spectrophotometric method has been developed the determination of Cobalt(II) and Cupper (II) .The method is based on the chelation of Co(II) and Cu(II) ions with 4-(4´-pyrazolon azo) -2-Naphthol(APAN) in aqueous medium . The complexes have a maximum absorption at (513) and (506) nm and ? max 0.531×10 4 and 0.12×10 5 L.mol -1.cm -1 for Co(II) and Cu(II) respectively .The reagent and two complexes have been prepared in ethanolic solution.The stoichiometry of both complexes were found to be 1:2 (metal :legend) .The effects of various cations and anions on Co(II) and Cu(II) determination have been investigated .The stability constants and standard deviations for Co(II) and Cu(II) 0.291 x107 ,0.909X108 L.mol
... Show MoreABSTRACT This study developed two adsorbents for extracting salbutamol sulphate (SAS) from water and urine samples after derivatisation with 2-aminobenzothiazole as a colour reagent. These adsorbents include cetylpyridinium chloride surfactant (CPC) modified silica and alumina-coated magnetite nanoparticles (Fe3O4/SiO2/CPC and Fe3O4/Al2O3/CPC). The derivatisation of SAS with the colour reagent resulted in an orange azo dye with maximum adsorption wavelengths of 443.0 nm. UV–Vis spectroscopy was used to identify the target analyte following the magnetic solid-phase extraction (MSPE) method. Under optimal conditions, the concentration ranges of 0.03–5.00 µg/mL and 0.05–6.00 µg/mL with good linearity (˃ 0.99), the detection limi
... Show More