Background: Meclizine hydrochloride (MCZ) is an antihistamine that is used as an antiemetic to prevent and cure nausea and vomiting. Because of its limited water solubility and first-pass metabolism, it exhibits variable absorption. Objective: To formulate and evaluate MCZ as an intranasal in situ gel with increased residence time and permeability. Methods: We made an inclusion complex of MCZ using various cyclodextrins as a complexing agent to help the drug dissolve better. The complexes were studied, and the ones that were better at dissolving were chosen to be used in the creation of an in situ gel with poloxamer 407 (17–20% w/v) and hyaluronic acid (0.25–0.75% w/v). Prepared formulas were subjected to various evaluation tests, and the optimum formula was subjected to an ex vivo permeation study. Results: Hydroxypropyl-cyclodextrin (HP-CD) complexation increased the solubility of MCZ. A prepared complex (10 mg of MCZ) was used for nasal in situ gel preparation. Formula (F3) containing 17% poloxamer 407 and 0.75% hyaluronic acid exhibited favorable characteristics, including optimal gelation temperature (33.33°C), drug content (100.51%), gel strength (35.0 seconds), spreadability (4.2 cm), and 98.52% in vitro drug release over 5 hours in simulated nasal fluid (pH 6.8), and provided considerably high permeability. Conclusions: A mucoadhesive in situ gel formulation of MCZ (HP-β-CD) is a promising nasal formulation for the management of nausea and vomiting.
Manual probing and periodontal charting are the gold standard for periodontal diagnosis that have been used in practice over a century. These methods are affordable and reliable but they are associated with some drawbacks that cannot be avoided. Among these issues is their reliance on operator’s skills, time-consuming and tedious procedure, lack sensitivity especially in cases of early bone loss, and causing discomfort to the patient. Availability of a wide range of biomarkers in the oral biofluids, dental biofilm, and tissues that potentially reflect the periodontal health and disease accurately encouraged their use as predictive/diagnostic/monitoring tools. Analysing biomarkers during care-giving to the patient using chairside kits i
... Show MoreBackground: This study was conducted to evaluate the surface roughness and dimensional accuracy of commercially obtainable alginate impression material in terms of imbibition after immersion in two different media. Materials and method: Two disinfecting agents, ethanol 70% and povidone-iodine 4%, were used to access the dimensional accuracy and surface roughness of alginate impression material. Weights of specimen discs of alginate impressions were measured before and immediately after immersion to gain a measure of imbibition. For surface roughness, disinfected specimens rectangle was examined before and after disinfection. Results: Minimal changes in weight were observed after disinfection, but a statistically non-significant differenc
... Show MoreThis research is determined by the study of the " cognitive references of the directorial imagination and modeling of the theatrical actor performance ." it has described an Iraqi theatrical model, The research began with the great importance of the director's imagination as the basic premise for crystallizing the director's vision according to its cognitive references in creating a solid performance model based on the aesthetic, intellectual and technical bases, It is also contributes to the formation of the theatrical show as a technical framework that presents the show in one unified fabric.
The research sought to reach through the problem of research, which is in the question of: What is the modeling of the
... Show MoreIn this work, samples of Cd2Si1-xGexO4 prepared by powder technology for (x = 0, 0.3, 0.6) were studied. The effect of (Ge) additives at different ratio of Ge (x=0, 0.3, 0.6) on the behavior of dielectric constant, dielectric loss and a,c conductivity were measured as a function of temperature at a selected frequencies (0.01 – 10) MHz in the temperature range 298 K to 473 K. The dielectric constant and dielectric loss obtained different behavior with the additives of (Ge). The activation energy for the electrical conduction process was studied.
This paper presents L1-adaptive controller for controlling uncertain parameters and time-varying unknown parameters to control the position of a DC servomotor. For the purpose of comparison, the effectiveness of L1-adaptive controller for position control of studied servomotor has been examined and compared with another adaptive controller; Model Reference Adaptive Controller (MRAC). Robustness of both L1-adaptive controller and model reference adaptive controller to different input reference signals and different structures of uncertainty were studied. Three different types of input signals are taken into account; ramp, step and sinusoidal. The L1-adaptive controller ensured uniformly bounded
... Show MoreTheligand4-[5-(2-hydoxy-phenyl)- [1,3,4- thiadiazole-2- ylimino methyl]-1,5-dimethyl -2-phenyl-1,2-dihydro-pyrazol-3-one [HL1] is prepared and characterized. It is reacted with poly(vinyl chloride) (PVC) in THF to form the PVC-L compounds ,PVC-L interacted with ions of transition metals to form PVC-L-MII complexes .All prepared compounds are characterized by FTIR spectroscopy, u.v-visible spectroscopy, C.H.N.S. analysis and some of them by 1HNMR
Vitamin D is a fat-soluble vitamin with antioxidant and DNA protecting properties , Levofloxacin is a member of the fluoroquinolone drug class, Its broad-spectrum bactericidal effect affects both Gram-positive and Gram-negative bacteria.
The goal of the study is to analyze the haematology analysis in rats received levofloxacin and show the preventive impact of vitamin D3 by analyzing the haematology parameters: packed cell volume (PCV), mean corpuscular hemoglobin concentration(MCHC),haemoglobin (HB), red blood cell (RBC), mean corpuscular volume (MCV),meancorpuscular haemoglobin(MCH), WBC ,differential WBC, and Platelets.
The study included 42 rats divided into 6 groups each group 7 rats. group I negative control
... Show MoreThe dielectric properties of polyvinyl chloride (PVC)-MnCl2 composite were studied by using the impedance technique. The measurements were carried out as a function of frequency in the range from 10 Hz to 13 MHz and temperature range from 27oC to 55oC. Using a composite of 20 wt. % MnCl2 by weight, it was found that the dielectric constants and the dielectric loss of the prepared films increase with the increasing temperature at law frequency and the enhancement of the ionic conduction which is confirmed by the increase the of AC. conductivity and the decrease of the activation energy of the conduction mechanism at high applied frequency. The observed relaxation and polarization effects of composite a
... Show More