Preferred Language
Articles
/
yhanUocBVTCNdQwCSET6
Spectrophotometric Determination of Co(II) in Vitamin B12 Using2-(biphenyl-4-yl)-3-((2-(2,4-dinitrophenyl) hydrazono)methyl) imidazo [1,2-a]pyridine as Ligand by Flow Injection–Merging Zone Analysis
...Show More Authors

Crossref
View Publication
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Development of an Eco-Friendly Method for Iron Extraction and Determination in Pharmaceuticals Using Ciprofloxacin Drug as Chelating agent
...Show More Authors

A method is developed for the determination of iron (III) in pharmaceutical preparations by coupling cloud point extraction (CPE) and UV-Vis spectrophotometry. The method is based on the reaction of Fe(III) with excess drug ciprofloxacin (CIPRO) in dilute H2SO4, forming a hydrophobic Fe(III)- CIPRO complex which can be extracted into a non-ionic surfactant Triton X-114, and iron ions are determined spectrophotometrically at absorption maximum of 437 nm. Several variables which impact on the extraction and determination of Fe (III) are optimized in order to maximize the extraction efficiency and improve the sensitivity of the method. The interferences study is also considered to check the accuracy of the procedure. The results hav

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Journal Of Al-nahrain University
DETERMINATION OF SERUM TRACE ELEMENTSMAGNESIUM, COPPER, ZINC, AND SELENIUM IN ASTHMATIC PATIENTS BY ATOMIC ABSORPTION SPECTROPHOTOMETRY
...Show More Authors

The aim of this study is to evaluate the levels of trace elements Magnesium (Mg), Zinc (Zn), Copper (Cu), and Selenium (Se) in blood sera of asthmatic patients by Atomic Absorption Spectrophotometry (AAS). The concentrations of Mg, Cu, and Zn have been determined by Flame Atomic Absorption spectrophotometry (FAAS), and Se with flameless Graphite Furnace Atomic Absorption Spectrophotometry (GFAAS). The study involves (55) asthmatic patients as study group and (28) subjects as control from both genders. Serum levels of Mg, Cu, and Se were significantly higher (p<0.001 for all) in patients when compared with healthy subjects, while Zn level was relatively significant (p<0.05). Our observations confirm the efficacy and applicability of (AAS) in

... Show More
Preview PDF
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Determination of Antibodies (IgG, IgM) against Toxoplasma gondii in Some Iraqi individuals by using ELISA technique
...Show More Authors

A total of 258 voluntary blood donors (males 101; females 157) in the age range of 18-52 yr among males and 18-55 yr among females were examined for Toxoplasma gondii antibodies (IgG), and (IgM) by immunological technique (Enzyme linked Immunosorbant Assay) during the period from March 2009 to April 2010. This study covered a wide range of factors including immunological, age ,sex , place of residence and symptoms that may have a possible relationship with toxoplasmosis. Results presented in this study showed clearly that 38 (14.7%) of individuals participated in this study having IgG Toxoplasma Ab, among those 10 samples (9.9%) were males and 28 samples (17.8%) were females. Moreover, we found the prevalence of IgM seropositivity in th

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Oct 12 2011
Journal Name
Journal Of Liquid Chromatography &amp; Related Technologies
RAPID DETERMINATION OF SPHINGANINE AND SPHINGOSINE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING MONOLITHIC COLUMN
...Show More Authors

A rapid high performance liquid chromatography method for the determination of sphinganine (Sa) and sphingosine (So) in urine samples by employing a silica-based monolithic column is described. The samples were first extracted using ethyl acetate and derivatized using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol. C20 sphinganine was used as internal standard. Under the optimized conditions, separation was achieved using a mixture of methanol:water (93:7, v/v), column temperature at 30°C, flow rate of 1 mL min−1, and an injection volume of 10 μL. Good linearity was obtained for Sa and So over the concentration range 20–500 ng mL−1(correlation coefficients ≥0.9978). The detection limits were 0.45 ng mL−1 for Sa and

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Jan 13 2015
Journal Name
European Journal Of Scientific Research
Determination of Priority Pollutant Phenols in PetroleumRefinery Wastewater and Tigris River Water by SPE-HPLC-UV
...Show More Authors

A solid Phase Extraction (SPE) followed by HPLC-UV method is described for the simultaneous quantitative determination of nine priority pollutant phenols : Phenol, 2- and 4-Nitrophenol, 2,4-Dimethylphenol, 2-, 2,4-Di-, 2,4,6-Tri-, and Penta- chlorophenol, 4 Chloro-3-methylphenol. The phenols were separated using a C-18 column with UV detector at wave length of 280nm. The Flow of mobile phase was isocratic consisted of 50:50 Acetonitrile: phosphate buffer pH=7.1, column temperature 45 C°, Flow Rate 0.7 ml/min. Calibration curves were linear (R2 = 0.9961-0.9995). The RSDs (1.301-5.805)%, LOD(39.1- 412.4) µg/L, LOQ(118.5-1250.8) µg/L, the Robustness (1.55-4.89), Ruggedness (2.82-4.00), Repeatability (2.1-4.95), Recoveries%

... Show More
Publication Date
Wed Sep 01 2021
Journal Name
Baghdad Science Journal
Determination of Sulfacetamide Sodium in Pure and Their Pharmaceutical Formulations by Using Cloud Point Extraction Method
...Show More Authors

      In this study, simple, low cost, precise and speed spectrophotometric methods development for evaluation of sulfacetamide sodium are described. The primary approach contains conversion of sulfacetamide sodium to diazonium salt followed by a reaction with p-cresol as a reagent in the alkaline media.  The colored product has an orange colour with absorbance at λmax 450 nm. At the concentration range of (5.0-100 µg.mL-1), the Beer̆ s Low is obeyed with correlation coefficient (R2= 0.9996), limit of detection as 0.2142 µg.mL-1, limit of quantification as 0.707 µg.mL-1 and molar absorptivity as 1488.249 L.mol-1.cm-1. The other approach, cloud point extraction w

... Show More
View Publication Preview PDF
Scopus (9)
Scopus Clarivate Crossref
Publication Date
Mon Oct 03 2016
Journal Name
Applied Research Journal
DETERMINATION OF THE GEOID HEIGHT (GEOID UNDULATION) BY USING MODERN SURVEYING TECHNOLOGIES
...Show More Authors

In this work, a large part of Baghdad University campus has been selected. The determination of Geoidal height for the local area requires Ground Control Points which both Ellipsoidal and Orthometric heights are known to compute the difference between them. The first step of the leveling process began by selected the Ground Control Points (GCPs) around the area of the work, and then divided them into two groups of the network traverse stations. They were leveled and adjusted depend on the number of the Bench Marks (B.M.s). Total Station TS (Nikon Nivo 5C) and Global Positioning System (GPS-Garmin 78 map) are used to do this application. The aim of the proposed work was to determine the height of the Geoid surface in the study area. The Geoi

... Show More
Publication Date
Wed Feb 22 2023
Journal Name
Iraqi Journal Of Science
Determination of Destruction Levels Caused by Earthquakes Using Grip RADIUS 99 Program
...Show More Authors

The most universal and basic damages caused by an earthquakes are buildings damage and human casualties. A simplified method, the RADIUS 99 Tool is used to calculate seismic intensity (shaking) distribution, buildings damage, number of casualties and lifelines damage, due to assumed earthquake scenario. In this study, Al - Kadhmiya sector in Baghdad city was chosen for assessing seismic risk, for this purpose, this area was divided into mesh of 1*1 km2 cell size, and a scenario of (Manjil) earthquake (that struck Iran in 1990) was utilized with following earthquake magnitudes (5 and 7), with epicenter distance (3, 10 and 100 km), and depths (2 and 5 km). It was found that, the best soil types for constructions are those with medium and h

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 03 2022
Journal Name
Physica Scripta
Radiation shielding properties of Cd-Bi-Pb-Zn-borate glasses: influence of Bi<sub>2</sub>O<sub>3</sub> activation
...Show More Authors
Abstract<p>We report the detail characterizations and <italic>γ</italic>-radiation protecting characteristics of some new types of cadmium (Cd)-bismuth (Bi)-lead (Pb)-zinc (Zn)-borate glasses of the form (70-x)B<sub>2</sub>O<sub>3</sub>-10ZnO-10PbO-10CdO-xBi<sub>2</sub>O<sub>3</sub> (with x = 0 to 20 mol%) synthesized via melt-quenching process. The influence of various Bi<sub>2</sub>O<sub>3</sub> contents on the <italic>γ</italic>-radiation shielding traits of the obtained glass samples was evaluated by exposing them at different <italic>γ</italic>-ray energies (0.356, 0.662, 1.173, and 1.33 MeV) whic</p> ... Show More
View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Baghdad Science Journal
Graphene Oxide Decorated with Nickel Cobaltite Nanoparticles as an Adsorbent for Cationic Methyl Green Dye: Kinetic, Isotherm, and Thermodynamic Studies
...Show More Authors

‎تم في هذه الدراسة ، تزيين ‏رقائق أكسيد الجرافين (‏GO‏) بجسيمات ‏كوبلتيت النيكل النانوية ‏NiCo2O4‎‏(‏NC‏) عن طريق الترسيب في ‏الموقع ، وتم استخدام المتراكب ‏المحضر (‏NC: GO‏) كسطح ماز لإزالة ‏صبغة الميثيل الخضراء ( ‏MG‏) من ‏المحاليل المائية. تم التحقق من ‏التغطية الناجحة لأوكسيد الجرافين ‏بجزيئات كوبلتيت النيكل النانوية ‏‏(‏NC‏) باستخدام دراسات ‏FT-IR‏ وحيود ‏الأشعة السينية (‏XRD‏). كانت أحجام  ‏الجسيم

... Show More
View Publication
Scopus (3)
Scopus Clarivate Crossref