osion and deposition are natural phenomena in rivers that can be identified by using velocity profiles and shear stress as indicators. The Shatt Al-Arab River located south of Iraq suffers from these phenomena. Based upon the basic principles of hydraulics, it is reasonably easy to identify shear stress distributions within the river reach of the Shatt Al-Arab; and that will allow us to know the locations of the erosion and deposition. For this purpose, a 2D model using HEC-RAS software was developed to simulate the flow within the lower reach of Shatt Al-Arab. The results showed that the maximum shear stress at the right bank of Shatt Al- Arab reached 0.1N/m2 at 12 km upstream of Ras- Al-Bisha. This value of shear stress was recorded during tide periods with the velocity at the right bank equal to 0.15m/s. In this case, the right bank will be exposed to erosion and needs more studies to find a solution. © 2022 EUROSIS-ETI. All Rights Reserved.
Objectives: The study aims: (1) To determine effectiveness of instructional health education vascular access on hemodialysis patients' knowledge, (2) To find out the association between effects of instructional health education vascular access and demographic characteristics of (age, gender and educational level). Methodology: A quasi experimental study –control study design is carried out at AL-Hussein Teaching Hospital in AL-Nasiriyah City, from 3November,2015 to 2 June, 2016. A non-probability (Purposive sample) of (80) patients with vascular access devices on maintenance hemodialysis patients divided int
Objective: The aims of present study to detect the effectiveness of instruction program of non-pharmacological guideline on blood pressure and laboratory test.
Methodology: A pre-experimental study was conducted in Al-Sader Teaching Hospital from 8th of September 2019 to 25th of May 2020, in order to find out the effectiveness of instruction program concerning non-pharmacological guideline on controlling essential hypertension among patients. A non- probability (purposive sample) of 50 patients with essential hypertension is selected. Those patients are already diagnosed with Essential Hypertension
... Show MoreSeveral parameters affect the properties of Portland cement and one of these parameters is the cooling rate of the clinker. If the effectiveness of the cooling method of the clinker increases, a good enhancement in the properties of Portland cement will be found. Depending on the new cooling method suggestion by Nasr et. al. [20], the counter pattern of air clinker flow was studied using (FLUENT 6.3.26). The dimensions of the cooling room in grate cooler, the constant mass flow rate of both clinker and air, different height ratios, and different clinker porosity were considered in this numerical work. The results show that the heat transfers in the first half of the cooling room (0 < X < 0.9 m) is larger than that in the secon
... Show MoreBackground: The overuse and inappropriate use of antibiotics cause antimicrobial resistance (AMR). The antibiotic stewardship program (ASP) plays a crucial role in improving prescribing antibiotics. Although the Iraqi Ministry of Health has issued ASP legislation, its full implementation in clinical practice remains incomplete. Objectives: To explore physicians' perspectives regarding the current and potential implementation of ASP in Al-Nasiriya hospitals. Methods: A qualitative study was conducted in Al-Nasiriyah public hospitals from December 17, 2023, to January 21, 2024, using face-to-face interviews. Physicians who prescribe antibiotics, work in Al-Nasiriyah public hospitals, and consent to participate in the study were recru
... Show MoreThis research involves study effect of chloride ions in concentration range (0.01 – 0.50 mol.dm-3) on the corrosion behavior of Al-Zn alloy in basic media of 1x10-3 mol.dm-3 NaOH at pH=11 and four different temperatures in the range (298-313 K). Cathodic and anodic Tafel slopes (bc &ba) and transfer coefficients (αc & αa) were calculated and the results interprets according to the variation of the rate – determining steps. The results also indicate that the chloride ions are bonded chemically in the interface as an initial step of formation of different mixed oxohydroxy – and chloro complexes. Polarization resistance (Rp) is calculates
... Show MoreAn overall mathematical model for copper pipe corrosion in flowing water was derived based on mass transfer fundamentals where we introduced the effects of boundary layer velocity, bulk flow velocity and the surface oxide protective film on the corrosion rate. A set of experiments were conducted in a straight 10mm diameter copper pipe, flow of water include six velocities of maximum value 7.33m/sec at 200C and 350C. The good agreement between the calculated and experimental corrosion rate values were achieved , the agreement reached 92% .
It is suitable to use precast steel-concrete composite beams to quickly assemble a bridge or a building, particularly in isolated regions where cast-in-situ concrete is not a practical option. If steel-concrete composite beams are designed to allow demountability, they can also be extremely useful in the aftermath of natural disasters, such as earthquakes or flooding, to replace damaged infrastructure. Furthermore, rapid replacement of slabs is extremely beneficial in case of severe deterioration due to long-term stressors such as fatigue or corrosion. The only way to rapidly assemble and disassemble a steel-concrete composite structure is to use demountable shear connectors to connect/disconnect the steel beams to/from the concrete slab. I
... Show MoreA ‘locking-bolt’ demountable shear connector (LBDSC) is proposed to facilitate the deconstruction and reuse of steel-concrete composite structures, in line with achieving a more sustainable construction design paradigm. The LBDSC is comprised of a grout-filled steel tube and a geometrically compatible partially threaded bolt. The latter has a geometry that ‘locks’ the bolt in compatible holes predrilled on the steel flange and eliminates initial slip and construction tolerance issues. The structural behaviour of the LBDSC is evaluated through nine pushout tests using a horizontal test setup. The effects of the tube thickness, strength of concrete slab, and strength of infilled grout on the shear resistance, initial stiffness, and du
... Show More