The present study employed the NAG-4SX3-3D analyzer to precisely measure the energy response of the sensor. The goal was to enhance the understanding of this technology by providing expert information about the device. This technology offers an economical, quick, accurate, and sensitive approach. By utilizing the turbidity method, Cyproheptadine hydrochloride (CPH) was quantified in pharmaceutical samples without the need for additional substances. CPH is expected to undergo a direct reaction with calcium hexacyanoferrate, resulting in the formation of white precipitates. The linear range for CPH measurement falls within the range of (0.008–30) mM. The relative standard deviation (RSD) for six repetitions at concentrations of (6 and 16) mM was found to be significantly less than 0.22%. The limit of detection (LOD) is 187.381 ng/analyte, calculated from the lowest concentration on the calibration graph through a progressive dilution. The correlation coefficient (r) from the linear dynamic range is 0.9991, with a linearity percentage (R2%) of 99.83. A comparison of the outcomes of the proposed method with an earlier technique (UV spectrophotometric at λmax of 274 nm) revealed them to be similar. However, the proposed procedure is more sensitive, requires fewer reagents, and yields superior results compared to the standard reference technique that employs 10 mM irradiation. It is worth noting that this technology is more sensitive but also requires a higher material consumption.
A simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the
... Show Morecapable of the measuring with a high degree of precision in a single instrument. Total stations device are used for station setting up, setting-outmany points from one station. Their major purpose of this work is to take advantage of total station for setting up building and to establish 3D representation using AutoCAD program. The area of the study was Civil Engineering Department at Baghdad University campus AL Jadiriyah. The completion of the work is done in two stages; 1. The field work: In this stage, the Total Station Nikon Nivo-5C was selected for the current study. This device was measured horizontal and vertical distance, elevations, and coordinates from a single set up. This data directly stored on memory. 2. The office work: In t
... Show MoreFibromyalgia (FM) is a common, debilitating, and chronic pain syndrome. The women are more likely to have more tender points on examination than are their male counterparts. Iraqi study showed that FM occur in 1.5% among adolescents of Iraqi population. In compare to normal healthy women, present study was revealed that Iraqi women with FM have significant elevation of calcium (p = 0.003) with significant reduction of magnesium (p = 0.001), whereas the inorganic phosphorous was not differs (p = 0.31). In conclusion, magnesium and calcium would play a crucial role in etiopathogenesis of fibromyalgia.
Key words: calcium, magnesium, phosphorous, Fibromyalgia.
New complexes have been prepared from the new ligand [2,2′‐(5,5‐dimethylcyclohexane‐1,3‐diylidene)bis(azan‐1‐yl‐1‐ylidene)dibenzoic acid] derived from 5,5‐dimethylcyclohexane‐1,3‐dione and 2‐aminobenzoic acid. Accordingly, its mono and binuclear Mn(II), Co(II), Cu(II), Zn(II), and Cd(II) complexes were prepared. The prepared components have been characterized by various spectroscopic techniques and elemental analysis. The thermal stability of the ligand and its complexes were performed by TGA. It was found that all the complexes have excellent thermal stability and do not contain water molecules within their structure, but the ligand has little stability. Additionally, theor
Visual analytics becomes an important approach for discovering patterns in big data. As visualization struggles from high dimensionality of data, issues like concept hierarchy on each dimension add more difficulty and make visualization a prohibitive task. Data cube offers multi-perspective aggregated views of large data sets and has important applications in business and many other areas. It has high dimensionality, concept hierarchy, vast number of cells, and comes with special exploration operations such as roll-up, drill-down, slicing and dicing. All these issues make data cubes very difficult to visually explore. Most existing approaches visualize a data cube in 2D space and require preprocessing steps. In this paper, we propose a visu
... Show MoreA spectrophotometric method has been proposed for the determination of two drugs containing phenol group [phenylephrine hydrochloride (PHP) and salbutamol sulphate (SLB)] in pharmaceutical dosage forms. The method is based on the diazotization reaction of metoclopramide hydrochloride (MCP) and coupling of the diazotized reagent with drugs in alkaline medium to give intense orange colored product (?max at 470 nm for each of PHP and SLB). Variable parameters such as temperature, reaction time and concentration of the reactants have been analyzed and optimized. Under the proposed optimum condition, Beer’s law was obeyed in the concentration range of 1-32 and 1-14 ?g mL-1 for PHP and SLB, respectively. The limit of detection (LOD) and l
... Show MoreThis research aims to develop transdermal patches of Ondansetron hydrochloride (OSH) with different types of polymers, ethyl cellulose and, polyvinyl pyrrolidone k30 in a ratio (3:0.5,3:1,3:2,2:1,1:1) with propylene glycol 20%w/w as a plasticizer. Prepared transdermal patches were evaluated for physical properties. The compatibility between the drug and excipients was studied by Differential scanning calorimetry (DSC), where there is no interaction between the drug and polymers. From the statistical study, there is a statistical difference between all the prepared formulations p<0.05. In-vitro Release study of transdermal patches was performed by using a paddle over the disc. The release profile of OSH follow
... Show MoreNew, simple and sensitive batch and reverse FIA spectrophotometric methods for the determination of doxycycline hyclate in pure form and in pharmaceutical preparations were proposed. These methods based on oxidative coupling reaction between doxycycline hyclate and 3-methylbenzothiazolinone-2-hydrazone hydrochloride (MBTH) in the presence ammonium ceric sulfate in acidic medium, to form green water-soluble dye that is stable and has a maximum absorbance at 626 nm. A calibration graph shows that a Beer's law is obeyed over the concentration range of 1-80 and 0.5-110 ?g.mL-1 of DCH for the batch and rFIA respectively with detection limit of 0.325 ?g.mL-1 of DCH for r-FIA methods. All different chemicals and physical experimental paramete
... Show MorePhosphorus is usually the limiting nutrient for eutrophication in inland receiving waters; therefore, phosphorus concentrations must be controlled. In the present study, a series of jar test was conducted to evaluate the optimum pH, dosage and performance parameters for coagulants alum and calcium chloride. Phosphorus removal by alum was found to be highly pH dependent with an optimum pH of 5.7-6. At this pH an alum dosage of 80 mg/l removed 83 % of the total phosphorus. Better removal was achieved when the solution was buffered at pH = 6. Phosphorus removal was not affected by varying the slow mixing period; this is due to the fact that the reaction is relatively fast.
The dosage of calcium chloride and pH of solution play an importa
Background: Obesity is a worldwide challenge and is closely
connected to many metabolic diseases. Two types of
adipose tissue, white adipose tissue (WAT) and brown
adipose tissue (BAT) have been identified. White fat cells
store chemical energy, brown adipocytes defend against
hypothermia, obesity and diabetes.
Objective: To localize and quantify brown adipocytes in
human subcutaneous (S) and visceral (V) adipose tissue by
histology and immunohistochemistry.
Type of the study: A cross –sectional study.
Methods: Adipose tissue was obtained from histopathology
specimens taken from ten patients, of different age, sex and
body mass index (BMI), undergoing surgery for different
pathologies