Preferred Language
Articles
/
yRabZogBVTCNdQwCKnbz
Comparison of corneal epithelial thickness profile in dry eye patients, keratoconus suspect, and healthy eyes
...Show More Authors
Purpose:

To compare the corneal epithelial thickness profile in patients with dry eyes and keratoconus suspect with normal healthy eyes.

Methods:

The study involved 120 eyes with an age range from 19 to 30 years. Forty eyes had normal corneal topography and no dry eyes. Forty eyes had dry eyes but had normal corneal topography. The last 40 eyes were keratoconus suspect and had no symptoms or signs of dry eyes.

Results:

Central epithelial thickness was not different statistically for all eyes. ( p-value: 0.1). The superior epithelial thickness was 53.5 µm ±3.1 in the control group, 53.4 µm ±3.5 in the dry eye group, and 53.6 µm ±2.8 in the keratoconus suspect group. No statistically significant difference was found ( p-value = 0.7). The inferior epithelial thickness was 55.7 µm ±3.5 in the control, 57.2 µm ±3.19 in the dry eyes, and 52.2 µm ±3.12 in the KC suspects. There was inferior thickening in the dry eyes and thinning in the KC suspects and this was statistically significant ( p-value < 0.01). Minimum epithelial thickness was 52.8 µm ±2.91 in the control and 53.2 µm ±3.51 in the dry eyes and it was located superiorly for both groups. In the KC suspects, the minimum thickness was 52.3 µm ±3.19 and was located inferiorly.

Conclusion:

In our study the epithelium appears to be thicker inferiorly in dry eyes and thinner in KC suspects. Displacement of thinnest location on epithelial map may be a helpful early sign of keratoconus. However, follow-up study is necessary to confirm the thinnest location displacement helped in this diagnosis.

Scopus Clarivate Crossref
View Publication
Publication Date
Mon Apr 04 2016
Journal Name
Iraqi Journal Of Physics
Thickness and gamma-ray effect on physical properties of CdO thin films grown by pulsed laser deposition
...Show More Authors

Polycrystalline Cadmium Oxide (CdO) thin films were prepared using pulsed laser deposition onto glass substrates at room temperature with different thicknesses of (300, 350 and 400)nm, these films were irradiated with cesium-137(Cs-137) radiation. The thickness and irradiation effects on structural and optical properties were studied. It is observed by XRD results that films are polycrystalline before and after irradiation, with cubic structure and show preferential growth along (111) and (200) directions. The crystallite sizes increases with increasing of thickness, and decreases with gamma radiation, which are found to be within the range (23.84-4.52) nm and (41.44-4.974)nm before and after irradiation for thickness 350nm and 4

... Show More
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Thickness and gamma-ray effect on physical properties of CdO thin films grown by pulsed laser deposition
...Show More Authors

Polycrystalline Cadmium Oxide (CdO) thin films were prepared
using pulsed laser deposition onto glass substrates at room
temperature with different thicknesses of (300, 350 and 400)nm,
these films were irradiated with cesium-137(Cs-137) radiation. The
thickness and irradiation effects on structural and optical properties
were studied. It is observed by XRD results that films are
polycrystalline before and after irradiation, with cubic structure and
show preferential growth along (111) and (200) directions. The
crystallite sizes increases with increasing of thickness, and decreases
with gamma radiation, which are found to be within the range
(23.84-4.52) nm and (41.44-4.974)nm before and after irradiation for

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Electronic diagnostics system for the analysis of laser beam profile
...Show More Authors

In this work the analysis of laser beam profile system ,using a two dimensional CCD (Charge Coupled Device) arrays, is established. The system is capable of producing video graphics that give a two dimensional image of laser beam. The video graphics system creates color distribution that represent the intensity distribution of the laser beam or the energy profile of the beam. The software used is capable of analyzing and displaying the profile in four different methods that is , color code intensity contouring , intensity shareholding, intensity cross section along two dimension x-y, and three dimensional plot of the beam intensity given in the same display.

View Publication Preview PDF
Publication Date
Tue Nov 30 2021
Journal Name
Iraqi Journal Of Science
Measurement of Pollution Level with Particulate Matter in Babylon Concrete Plant and Evaluation of Oxidative Stress and Hematological Profile of Plant Workers
...Show More Authors

The impact of exposure to different sizes of particulate matter (PM1, PM2.5, PM7, and PM10) was evaluated in  Babylon concrete plant workers who had been exposed to concrete dust for at least 10 years.  The effects of  these particles on the hematological parameters, malondialdehyde (MDA) levels, and  antioxidant enzymes (catalase and glutathione peroxidase ) were examined. The results exhibited that the levels of PM2.5 and PM10 were higher than the acceptable limits approved by the National Ambient Air Quality Standards (NAAQS). The blood parameters, namely white blood cells (WBC), red blood cell (RBC) and platelets counts, demonstrated non-significant differences between workers exposed to the PM as compared to the control gro

... Show More
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Sat Mar 21 2020
Journal Name
Electronic Journal Of General Medicine
The Possible Immunological Pathways for the Variable Immunopathogenesis of COVID—19 Infections among Healthy Adults, Elderly and Children
...Show More Authors

View Publication
Scopus (111)
Crossref (118)
Scopus Clarivate Crossref
Publication Date
Thu Dec 05 2024
Journal Name
Shifaa
Evaluating alveolar bone thickness in upper and lower incisors from orthodontic perspective. A Cone beam computed tomography-based retrospective study
...Show More Authors

Purpose: This study aimed to assess the thickness of alveolar bone of maxillary and mandibular incisors from orthodontics perspective. Materials and Method: A total of 73 Cone beam computed tomography for Iraqi patients (47 females and 26 males) were included in this study. The selected images were captured and imported to AutoCAD database software to perform the measurement. To measure alveolar bone thickness, a reference line was drawn through the long axis of each incisor, from the incisal edge to the root apex. Then, labial and lingual/palatal perpendicular lines were drawn to the reference line at 3, 6, and 9mm apically from the cemento-enamel junction (CEJ). Results: The buccal bone is generally thinner than the lingual/palata

... Show More
View Publication
Crossref
Publication Date
Mon Feb 25 2019
Journal Name
Iraqi Journal Of Physics
Simulation of thermal lensing in an end-pumped Nd:YAG laser rod with Gaussian and super-Gaussian pump beam profile
...Show More Authors

A numerical simulation is made on the thermal lensing effect in an laser diode end-pumped Nd:YAG laser rod. Based on finite element method (FEM), the laser rod temperature distribution is calculated and the focal length is deduced for a Gaussian and super-Gaussian pump beam profiles.

At the pump power of 20W, the highest temperature located at the center of end-pumped face was 345K, and the thermal lens focal length was 81.4mm along the x-z axis. 

The results indicate that the thermal lensing effect sensitively depend on the pump power, waist radius of the pump beam and the pump distribution in a laser rod geometry.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Effects of Melatonin On The Oxidative Stress , Protein Glycation , Microalbuminuria and Lipid Profile In Type II Diabetes Mellitus
...Show More Authors

Previous studies indicated that supplementation with antioxidants has a protective effects against oxidative stress–induced damage in type 2 diabetes. In this study we evaluated the antioxidant effects of melatonin on the oxidative stress parameters and microalbuminuria in type 2 DM patients. 30 patients with type 2 DM were treated with 3mg/day melatonin for 90 days. Erythrocytes and plasma MDA and glutathione, fasting plasma glucose, %HbAIC, microalbuminuria, total plasma protein and lipid profile were measured each 30 days and compared with those obtained from 20 healthy controls.

A decrease in MDA levels associated with the elevation in GSH levels were observed, compared with the pre–treatment levels.

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Mar 14 2022
Journal Name
International Journal Of Health Sciences
Comparing the histological effect of Thymol from multiple sources with blood lipids profile and liver enzymes in Albino Mice
...Show More Authors

The therapeutic value of the phenolic component and pure thymol was well known; this study comprised the extraction of crude phenol from two plants (Thymus vulgaris and Artemisia annua) which contain thymol with pure thymol and evaluate their effect on hematological and histological by using three different concentrations of each plant extract and pure thymol to tested them on lab mice. All the mice were allowed free access to water and feed for 21 days in laboratory conditions; orally, pure water was administered to the control mice (group I), while groups II, III, and IV were given orally with T. vulgaris, A. annua, combination of last two crude phenol plant extract 50:50 and pure thymol respectively. The levels of CHO, TRI, and HDL were

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Baghdad Science Journal
Thermodynamic Investigation of Partially Purified Paraoxonase in the Sera of Healthy Pregnant Women Compared to Women with Pregnancy Complication
...Show More Authors

The thermodynamic constanting of “crude and partially purified” Paraxonase(PON) was evaluated in the sera of “healthy and ectopic” pregnant women in order to characterize the reaction of PON with diethyl para-nitro phenyl phosphate as substrate.This study was performed on (17) women with ectopic pregnancy (EP) whose age between (25-55) years  and (25) normal pregnant women with  a mean age of (25 -55) years as  a control group . Samples were collected from the Medical City, AL-Yarmook and Fatema AL-Zahraa hospitals during the period from Sep.2011 to April 2012.The study included the evaluation  of “paraxonase activity, specific activity and total protein” in the (crude and partially purified) sera of EP pa

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref