Preferred Language
Articles
/
yRa7n4cBVTCNdQwCjFgz
Calculation of Radiation Nuclei Concentrations in Fertilized and Unfertilized Plants Samples Using Gamma Spectroscopy
...Show More Authors

The aim of this work was to estimate the concentrations of natural and artificial nuclides in some fertilized and unfertilized plant samples. These samples were collected and prepared in a petri dish for the measurements using gamma spectroscopy. The average values of 238U, 232Th, 40K, and 137Cs for the unfertilized plant samples were (11.964 ± 3.226, 8.273 ± 2.639, 402.436 ± 18.099, and 2.761 ± 1.613) respectively, and for the fertilized plant samples were (30.434 ± 5.282, 22.584 ± 4.620, 711.332 ± 25.806, and 6.986 ± 2.542) respectively. The average values of radiological hazard indices, Raeq, D, D for 137Cs, (AEDE)in, (AEDE)out, Iγ, Hin, and Hout for the unfertilized plant samples were (54.782 ± 7.216, 27.306, 0.469, 0.134, 0.033, 0.431, 0.180, and 0.148) respectively, and for the fertilized plant samples were (117.502 ± 10.747, 57.364, 1.188, 0.281, 0.070, 0.903, 0.400, and 0.317) respectively. The present results have indicated that the fertilized plant samples have more concentrations than the unfertilized plant samples.

Scopus Crossref
View Publication
Publication Date
Sun Oct 22 2023
Journal Name
Iraqi Journal Of Science
Study of Matter Density Distributions, Elastic Electron Scattering form Factors and Reaction Cross Sections of 8He And 17B Exotic Nuclei
...Show More Authors

The ground state densities of unstable neutron-rich 8He and 17B exotic nuclei are studied via the framework of the two-frequency shell model (TFSM) and the binary cluster model (BCM). In TFSM, the single particle harmonic oscillator wave functions are used with two different oscillator size parameters βc and βv where the former is for the core (inner) orbits and the latter is for the valence (halo) orbits. In BCM, the internal densities of the clusters are described by single particle Gaussian wave functions. Shell model calculations for the two valence neutrons in 8He and 17B are performed via the computer code OXBASH. The long tail performance is clearly noticed in the calculated neutron and matter density distributions of these nucl

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 29 2013
Journal Name
Journal Of Statistics Applications & Probability
Analyzing Skewed Data with the Epsilon Skew Gamma distribution
...Show More Authors

A new distribution, the Epsilon Skew Gamma (ESΓ ) distribution, which was first introduced by Abdulah [1], is used on a near Gamma data. We first redefine the ESΓ distribution, its properties, and characteristics, and then we estimate its parameters using the maximum likelihood and moment estimators. We finally use these estimators to fit the data with the ESΓ distribution

Crossref (5)
Crossref
Publication Date
Thu Mar 09 2017
Journal Name
Sensors
A Multimodality Hybrid Gamma-Optical Camera for Intraoperative Imaging
...Show More Authors

The development of low profile gamma-ray detectors has encouraged the production of small field of view (SFOV) hand-held imaging devices for use at the patient bedside and in operating theatres. Early development of these SFOV cameras was focussed on a single modality—gamma ray imaging. Recently, a hybrid system—gamma plus optical imaging—has been developed. This combination of optical and gamma cameras enables high spatial resolution multi-modal imaging, giving a superimposed scintigraphic and optical image. Hybrid imaging offers new possibilities for assisting clinicians and surgeons in localising the site of uptake in procedures such as sentinel node detection. The hybrid camera concept can be extended to a multimodal detec

... Show More
View Publication
Scopus (24)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Thu Feb 11 2021
Journal Name
Physics In Medicine & Biology
Stereoscopic portable hybrid gamma imaging for source depth estimation
...Show More Authors
Abstract<p>Advances in gamma imaging technology mean that is now technologically feasible to conduct stereoscopic gamma imaging in a hand-held unit. This paper derives an analytical model for stereoscopic pinhole imaging which can be used to predict performance for a wide range of camera configurations. Investigation of this concept through Monte Carlo and benchtop studies, for an example configuration, shows camera-source distance measurements with a mean deviation between calculated and actual distances of <5 mm for imaging distances of 50–250 mm. By combining this technique with stereoscopic optical imaging, we are then able to calculate the depth of a radioisotope source beneath a surfa</p> ... Show More
View Publication
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Thu May 28 2020
Journal Name
Iraqi Journal Of Science
Palynofacies and Source Rocks Evaluation for Selected Samples of Subba Oil Field, Southern Iraq
...Show More Authors

This study includes a palynological and organic geochemical evaluation of Nahr Umr, Zubair, and Yamama Formations in the Subba field, Southern Iraq, represented by three wells (Su-14, Su-9 and Su-8). The determination of quantity organic matter showed that the rocks of Nahr Umr Formation had a total organic carbon of 4.76%, indicating very good production of hydrocarbons where type (II) kerogen was dominant, but the rocks were thermally immature. Zubair Formation had a total organic carbon of 1.91% to 2.26%, indicating good to very good production of hydrocarbons where kerogen of types (I) and (II/III) were dominant, with low thermal maturity. Yamama Formation showed a total organic carbon of 1.68%, revealing good production of hydrocarb

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Sat Mar 26 2022
Journal Name
Indian Journal Of Ecology
Assessment of Antimicrobial Resistance to Klebsiella pneumonia Isolated from Various Clinical Samples in Baghdad
...Show More Authors

Klebsiella pneumoniae is a severe opportunistic strain of enteric bacteria that is a major cause of urinary tract infection and pneumonia. This study was conducted in Baghdad City during September 2020-November 2020 on 50 clinical samples of urine, vaginal, sputum, wound swabs, ear swabs, and burn swabs. strains were identified using the VITEK-2 compact system and tested in K. pneumoniae terms of susceptibility to various antimicrobial drugs by Kirby-Bauer test. The isolates were more predominant in the females (56%) compared to males (44%). The antibiotic resistance rate of varied among different isolated clinical sample sources. K. pneumoniae K. pneumoniae isolated from different clinical specimens differed with respect

... Show More
Preview PDF
Publication Date
Thu Dec 31 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
EFFECT OF ANIMAL FEED SUPPLEMENTATION WITH DIFFERENT CONCENTRATIONS OF FENUGREEK SEEDS (Trigonellafoenumgraecum) ON ANIMAL PRODUCTION AND MICROBIAL CHICKEN MEAT.: EFFECT OF ANIMAL FEED SUPPLEMENTATION WITH DIFFERENT CONCENTRATIONS OF FENUGREEK SEEDS (Trigonellafoenumgraecum) ON ANIMAL PRODUCTION AND MICROBIAL CHICKEN MEAT.
...Show More Authors

This study was conducted in the poultry field of Al-Mustansiriya University/ Baghdad, to show the effect of adding different levels 0, 1, 5 and 10% of the fenugreek seeds in the rations containing many contaminated microbes on the productive performance of broilers. 150-day-old rose meat was used with a 41 average weight (gm), were randomly allocated to 4 treatments with 3 replicates, and for each treatment 15 chicks per repetition: 0, 1, 5, and 10% (T0-T3), respectively. The results of this study showed that fenugreek seeds contain good amounts of protein, fat, ash and carbohydrates, which are 24.92, 8.82, 3.08 and 54.28 respectively. Fenugreek seeds also have high levels of tannins, coumarins and flavones, followed by saponins,

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 01 2024
Journal Name
Materials Letters
Determination of third order susceptibility of carbon quantum dots at different concentrations
...Show More Authors

The nonlinear refractive (NLR) index and third order susceptibility (X3) of carbon quantum dots (CQDs) have been studied using two laser wavelengths (473 and 532 nm). The z-scan technique was used to examine the nonlinearity. Results showed that all concentrations have negative NLR indices in the order of 10−10 cm2/W at two laser wavelengths. Moreover, the nonlinearity of CQDs was improved by increasing the concentration of CQDs. The highest value of third order susceptibility was found to be 3.32*10−8 (esu) for CQDs with a concentration of 70 mA at 473 nm wavelength.

View Publication
Crossref
Publication Date
Wed Dec 04 2013
Journal Name
Proceedings Of Nuclei Of Seyfert Galaxies And Qsos - Central Engine &amp; Conditions Of Star Formation — Pos(seyfert 2012)
Are Narrow Line Seyfert 1 galaxies a special class of Active Galactic Nuclei?
...Show More Authors

No. Due to their apparently extreme optical to X-ray properties, Narrow Line Seyfert 1s (NLSy1s) have been considered a special class of active galactic nuclei (AGN). Here, we summarize observational results from different groups to conclude that none of the characteristics that are typically used to define the NLSy1s as a distinct group – from the, nowadays called, Broad Line Seyfert 1s (BLSy1s) – is unique, nor ubiquitous of these particular sources, but shared by the whole Type 1 AGN. Historically, the NLSy1s have been distinguished from the BLSy1s by the narrow width of the broad Hb emission line. The upper limit on the full width at half maximum of this line is 2000kms−1 for NLSy1s, while in BLSy1s it can be of several thousands

... Show More
View Publication
Crossref
Publication Date
Mon Jan 30 2023
Journal Name
Iraqi Journal Of Science
Design and Creating a Specific Neutron Irradiation Instrument to Decrease the User’s Radiation Exposure Time
...Show More Authors

      A specialized irradiation instrument "created instrument" was  designed and created from various kinds and sizes of available plastic household-waste materials. In addition, a neutron beam collimator with a lid was designed  and implemented. The collimator is with dimensions of 25 cm in height and 10 cm in inner diameter, while the lid dimensions are 11.5 cm height and outer diameter of 9.9 cm  to perfectly match the inner diameter of the collimator with the possibility of movement (opening and closing), and also the shielding of the radioactive 241Am/Be neutron source with a recent activity of 37.5 mCi.

To investigate the efficiency of the "created instrument", ten hydrogenous material samples (ordinary p

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref