The aim of this work was to estimate the concentrations of natural and artificial nuclides in some fertilized and unfertilized plant samples. These samples were collected and prepared in a petri dish for the measurements using gamma spectroscopy. The average values of 238U, 232Th, 40K, and 137Cs for the unfertilized plant samples were (11.964 ± 3.226, 8.273 ± 2.639, 402.436 ± 18.099, and 2.761 ± 1.613) respectively, and for the fertilized plant samples were (30.434 ± 5.282, 22.584 ± 4.620, 711.332 ± 25.806, and 6.986 ± 2.542) respectively. The average values of radiological hazard indices, Raeq, D, D for 137Cs, (AEDE)in, (AEDE)out, Iγ, Hin, and Hout for the unfertilized plant samples were (54.782 ± 7.216, 27.306, 0.469, 0.134, 0.033, 0.431, 0.180, and 0.148) respectively, and for the fertilized plant samples were (117.502 ± 10.747, 57.364, 1.188, 0.281, 0.070, 0.903, 0.400, and 0.317) respectively. The present results have indicated that the fertilized plant samples have more concentrations than the unfertilized plant samples.
Background: Understanding the morphological characteristics between the floor of the maxillary sinus and the tips of the maxillary posterior roots is crucial in orthodontics involving diagnosis and treatment planning. The aim of this study was to evaluate the distances from the maxillary posterior root apices to the inferior wall of the maxillary sinus, thickness and density of maxillary sinus floor using cone-beam computed tomography images and the relationships between roots and maxillary sinus according to gonial angle and skeletal pattern. Materials and methods: Three-dimensional images of each root were checked, and the distances were measured along the true vertical axis from the apex of the root to the sinus floor, and the thickne
... Show MoreObjective: The present study was aimed to develop a pH-triggered in situ gel for local release of lidocaine hydrochloride (lidocaine HCL) in the buccal cavity to improve the anesthetic effect of this amino amide drug which has very high water solubility. The formulations were introduced to the oral cavity as a spray to improve compliance and for easier administration.Methods: In this work, two grades of carbopol (934 and 940)-based in situ gel spray were designed. The formulations containing lidocaine HCl 5% were prepared by mixing different concentrations of carbopol with xanthan gum. Eight formulations were investigated and evaluated for gelation capacity, spray angle, volume of solution delivered per each actuation, rheological p
... Show MoreAn experiment was conducted at the laboratories of College of Agriculture – Kerbala University during 2016. The aim of this study was to the effect of water extracts of medicinal plants germination percentage and development of plumule and radicle growth .The completely randomized design with three replicates was usedin each experiment consisted of water extracts (T1= Distilled water),(T2= Eruca sativa Eruca sativa L),(T3= Fenugreek ïºï»Ÿïº¤ï» ﺒﺔTrigonella foenum - graecum L),(T4= Sweet FennelFoeniculum vulgare.Mill),(T5=Borage Anchusa strigosa Lab),(T6=Dill Anethum graveolens L) ,(T7=Black cuminNigella Sativa L),(T8=Cumin Cuminumcyminum L),(T9= CorianderCoriandrum sativum L. ). Results of Lab.
... Show MoreAt thermal energies near stellar conditions, nuclear reactions are sensitive to resonance strengths of the nuclear reaction cross-section. In this paper, the resonance strengths of nuclear reaction were evaluated numerically by means of nuclear reaction rate calculations using a written Matlab code, at the energies of interest in stellar nuclear reactions. The results were compared with standard reaction before and after application of a statistical analyses, to select the best parameters that made theoretical results as close as possible to the standard values. Fitting was made for different temperature ranges up to 10 GK, 0.6 GK and 0.25 GK. The evaluated results showed that as the temperature range becomes narrower, more error is ad
... Show MoreObjectives To compare the clinical efficacy of microvascular decompression surgery (MVD) and gamma knife radiosurgery (GKR) as a treatment for patients with primary trigeminal neuralgia (TN) and evaluate the outcome regarding pain relief, recurrence, and complications with both modalities of treatment. Patients and Methods A randomized prospective study conducted in SaadAlwitry Neurosciences Hospital, Baghdad, Iraq. Eighty-four patients with TN from January 2016 to January 2018, 45 patients had GKR while 39 patients treated with MVD. The pain evaluated pre-and post-operatively using the Barrow Neurological Institute Pain Intensity scale (BNIPI), visual analog scale (VAS) and Brief Pain Inventory Facial (BPI-Facial) scoring systems. In GKR p
... Show MoreThe Atmospheric Infrared Sounder (AIRS) on EOS/Aqua satellite provides diverse measurements of Methane (CH4) distribution at different pressure levels in the Earth's atmosphere. The focus of this research is to analyze the vertical variations of (CH4) volume mixing ratio (VMR) time-series data at four Standard pressure levels SPL (925, 850, 600, and 300 hPa) in the troposphere above six cities in Iraq from January 2003 to September 2016. The analysis results of monthly average CH4VMR time-series data show a significant increase between 2003 and 2016, especially from 2009 to 2016; the minimum values of CH4 were in 2003 while the maximum values were in 2016. The vertical distribution of CH4<
... Show MoreObjectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamm
... Show More