To detect the amount of rifampicin in bulk and medicinal dosage formulations, an accurate and costeffective UV spectrophotometric technique has been developed using the area under the peak to estimate the presence of rifampicin. This range of wavelengths (300–356 nm) was chosen. The method showed linearity in the 2–22 μg/mL range, with R2 being2 0.9996. The developed method’s linearity, detection limit, quantification limit, precision, repeatability, and accuracy were all statistically and experimentally validated. The suggested methodology can be used for routine quality control analysis of rifampicin in pure form and in capsule dosage form, as demonstrated by the satisfactory recovery percentage results. This study explores the structural and electronic properties of rifampicin using density functional theory (DFT) and its interaction with potential biological targets via molecular docking. The DFT analysis, conducted using the B3LYP functional and a suitable basis set, provides detailed insights into the optimized molecular geometry, frontier molecular orbitals (FMOs), and molecular electrostatic potential (MEP) of rifampicin. The energy gap (ΔE = 2.878 eV) exported the stability conditions of rifampicin. Reduced density gradient analysis (RDG/NCI) was considered to highlight the specific interactions present inside the molecule, predicting its stability. Molecular docking studies complement the DFT analysis by identifying rifampicin binding affinity (-36.01 kcal/ mol) with the specific 5F92 target protein. This study evaluates the ADMET properties of Rifampicin to assess its pharmacokinetic and safety profile.
المستودع الرقمي العراقي. مركز المعلومات الرقمية التابع لمكتبة العتبة العباسية المقدسة
This research work aims to the determination of molybdenum (VI) ion via the formation of peroxy molybdenum compounds which has red-brown colour with absorbance wave length at 455nm for the system of ammonia solution-hydrogen peroxide-molybdenum (VI) using a completely newly developed microphotometer based on the ON-Line measurement. Variation of responses expressed in millivolt. A correlation coefficient of 0.9925 for the range of 2.5-150 ?g.ml-1 with percentage linearity of 98.50%. A detection limit of 0.25 ?g.ml-1 was obtained. All physical and chemical variable were optimized interferences of cation and anion were studied classical method of measurement were done and compared well with newly on-line measurements. Application for the use
... Show MoreThe existing investigation explains the consequence of irradiation of violet laser on the structure properties of MawsoniteCu6Fe2SnS8 [CFTS] thin films. The film was equipped by the utilization of semi-computerized spray pyrolysis technique (SCSPT), it is the first time that this technique is used in the preparation and irradiation using a laser. when the received films were processed by continuous red laser (700 nm) with power (>1000mW) for different laser irradiation time using different number of times a laser scan (0, 6, 9, 12, 15 and 18 times) with total irradiation time (0,30,45,60,75,90 min) respectively at room temperature.. The XRD diffraction gave polycrysta
... Show MoreIn this article four samples of HgBa2Ca2Cu2.4Ag0.6O8+δ were prepared and irradiated with different doses of gamma radiation 6, 8 and 10 Mrad. The effects of gamma irradiation on structure of HgBa2Ca2Cu2.4Ag0.6O8+δ samples were characterized using X-ray diffraction. It was concluded that there effect on structure by gamma irradiation. Scherrer, crystallization, and Williamson equations were applied based on the X-ray diffraction diagram and for all gamma doses, to calculate crystal size, strain, and degree of crystallinity. I
... Show More