Electrical resistivity tomography (ERT) methods have been increasingly used in various shallow depth archaeological prospections in the last few decades. These non‐invasive techniques can save time, costs, and efforts in archaeological prospection and yield detailed images of subsurface anomalies. We present the results of quasi‐three‐dimensional (3D) ERT measurements in an area of a presumed Roman construction, using a dense electrode network of parallel and orthogonal profiles in dipole–dipole configuration. A roll‐along technique has been utilized to cover a large part of the archaeological site with a 25 cm electrode and profile spacing, respectively. We have designed a new field procedure, which used an electrode array fixed in a frame. This facilitated a very efficient field operation, and overall a total of 9648 electrode positions were occupied. The 3D ERT inversion results clearly characterize the main structures of the Roman foundations. We compared our high‐resolution 3D electrical resistivity model with findings from archaeological excavations, which have been done in some parts of the surveyed area. The ERT result coincide well with the excavation results, i.e. the location as well as the vertical and horizontal extensions of the structures could be precisely imaged. The ERT results successfully images most parts of the walls, pits and also smaller internal structures of the Roman building; moreover, excavation ditches that had been refilled prior to the ERT survey are delineated as resistivity heterogeneities as well.
For structural concrete members that may expose to serious earthquake, overload or accident impact, the design of ductility must be given the same importance as the flexural strength. The aim of this investigation is to study the change in ductility of structural concrete flexural members during their exposure to limited cycles of repeated loading. Twenty full-scale beam specimens have been fabricated in to two identical groups; each group consisted of ten specimens. The first group was tested under monotonic static loading to failure and regarded as control beams, while the specimens of the second group were subjected to ten cycles of repeated loading with constant load interval, which ranged between 40% and 60% of ultimate load. S
... Show MoreThis work presents experimental research using draped prestressed steel strands to improve the load-carrying capacity of prestressed concrete non-prismatic beams with multiple openings of various designs. The short-term deflection of non-prismatic prestressed concrete beams (NPCBs) flexural members under static loading were used to evaluate this improvement. Six simply supported (NPCBs) beams, five beams with openings, and one solid specimen used as a reference beam were all tested as part of the experiment. All of the beams were subjected to a monotonic midpoint load test. The configuration of the opening (quadrilateral or circular), as well as the depth of the chords, were the varia
The aim of this research to examine the impact of different level of Insulin certain biomarkers of local roosters semen after being cooling for varying lengths of periods, roosters semen pooled, diluted with extender, and distributed randomly among five groups: Diluted semen put through the semen cryopreservation technique; the control treatment (C1) 0 insulin; (C2) contained 4 IU/insulin; (C3) contained 5 IU/insulin; (C4) contained 6 IU/insulin; and (C5) contained 7 IU/insulin. After 0, 24, 48 and 72 hours, cooling semen were evaluated for plasma membrane integrity(MI), acrosome integrity(AI), malondialdehyde (MDA) and total antioxidant capacity (TCA). The result showed significant d
Backgr ound: The transfer of the tibialis posterior tendon to the anterior aspect of the ankle not only replaces the function of the paralyzed muscles, but also removes the deforming force on the medial aspect of the foot. Objecti ves: In this study, we evaluated patients who underwent tibialis posterior tendon transfer for the treatment of foot drop, and comparison through interosseous membrane route versus anterior to lower tibia route of tibialis posterior tendon transfer, with evaluation of the results according to carayon criteria Methods: Nine patients with foot drop secondary to different causes treated with tibialis posterior tendon transfer from January 2011 to January 2012 were followed up for a mean of 12 months in Al Kindy Teach
... Show MoreThe resistance of Staphylococcus aureus to ciprofloxacin has complicated the problem of treating staphylococcal associated infections in which MRSA is the causative agent since ciprofloxacin was the drug of choice to treat such infections. Our study investigated the incidence of Ciprofloxacin resistant S. aureus isolates that were also methicillin resistant among Iraqi patients. The obtained bacterial isolates were tested for Ciprofloxacin resistance using agar dilution method and the sequence of gyrA and parC. The results revealed that about 8% of the isolated MRSA strains were Ciprofloxacin resistant and the resistance was due to mutation in gyrA rather than parC.
In this work, we have investigated optical properties of the thermally evaporation PbS/CdS thin films. The optical constant such as (refractive index n, dielectric constant εi,r and Extinction coefficient κ) of the deposition films were obtained from the analysis of the experimental recorded transmittance spectral data. The optical band gap of PbS/CdS films is calculate from (αhυ)1/2 vs. photon energy curve.