Preferred Language
Articles
/
xhYDfYgBVTCNdQwCrHd3
Prospective Comparative Study of Fixing Displaced Transverse Patellar Fracture by Tension Band Wiring Versus Cannulated Screws with Wiring
...Show More Authors

BACKGROUND: Transverse fractures of the patella are important fractures with a wide variety of subtypes, the common incidence in the age group of 20–50 years. Surgical interference aims to achieve a perfect alignment of the joint surface, in addition to rigid fixation of the fracture for early re-habitation and early movement to retain the extensor mechanism of the knee joint. AIM: The aim of this study was to compare the radiological and functional outcomes of the displaced transverse patella fracture in adult patients treated by ORIF using tension band wiring versus cannulated screws with wiring. METHODS: A prospective analytic comparative study was conducted in Al-Kindy Teaching Hospital/Baghdad/Iraq for 18 months from April 1, 2019, to October 1, 2020. It included 32 patients with isolated displaced transverse patellar fracture AO type 34-C1. The patients have undergone operative fixation with two different surgical techniques divided randomly by choosing every other patient into two groups. Group A, the fracture was fixed by cannulated screws with wiring and Group B, the fracture was fixed by two K-wires and with tension band technique. Postoperatively, assessment of the knee function by Lysholm score, the visual analog scale for pain intensity, and active flexion range of movement were measured in degree as primary outcomes, while time to union in weeks assessed radiographically as secondary outcomes. RESULTS: The patients’ age was ranging from 26 to 49 years, with males predominant. Low-energy falls occupying a major part of the mechanism of injury in both groups. Lysholm score was significantly increased after 3, 6, and 12 months compared to that after 1 month in both groups with no statistical differences. The mean visual analog score significantly decreased in Group A after 1 month than that in Group B with no significant change in the other follow-up periods. There were no statistically significant differences in both groups regarding the range of knee movement and the radiographic assessment of fracture healing. CONCLUSION: Both techniques are good and effective with taking into consideration that open reduction and cannulated screws fixation with wiring technique is shown to be associated with lower post-operative pain and a lower frequency of complications mainly surgical site infection.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Geological Journal
Assessment of the Contamination of Baghdad Soils with Lead Element
...Show More Authors

The present study aims to study the content and spatial distribution of lead (Pb) contamination in the soils of some Baghdad cities (Middle of Iraq). Twenty soil samples were randomly collected from different land-use in the studied area at a depth between 5 to 30 cm. Ten samples are collected from Al-Rissafa side areas (Adhamiya, Al-Wazeeria (Battery Manufacturer), Shikh Omer, Ziyouna, Karada, Shaab, Sadr city, Al-Za’franiya, Al-Dora expressway, and Alselikh ) and other ten samples are collected from Al-Krakh side areas Al-Dora, Al-Masafi junction, Al-Dora, Sayidia, Al-Salam university college, Al-Bayaa (Industrial District), Jehad, Amirya, Abu Ghraib, Al-hurriya, and Kadhimiya. The soil samples have been analyzed for the lead (P

... Show More
View Publication
Scopus (6)
Crossref (1)
Scopus Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Interaction of Aqueous Cu2+ Ions with Granules of Crushed Concrete
...Show More Authors

The sorption of Cu2+ ions from synthetic wastewater using crushed concrete demolition waste (CCDW) which collected from a demolition site was investigated in a batch sorption system. Factors influencing on sorption process such as shaking time (0-300min), the initial concentration of contaminant (100-750mg/L), shaking speed (0-250 rpm), and adsorbent dosage (0.05-3 g/ml) have been studied. Batch experiments confirmed that the best values of these parameters were (180 min, 100 mg/l, 250 rpm, 0.7 g CCDW/100 ml) respectively where the achieved removal efficiency is equal to 100%. Sorption data were described using four isotherm models (Langmuir, Freundlich, Redlich-Peterson, and Radke-Prausnitz). Results proved that the pure ads

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Fri Jan 24 2020
Journal Name
Iraqi Journal Of Agricultural Sciences
RESPONSE OF ABELMOSCHUS ESCULENTUS L. FORINOCULATION WITH MYCORRHIZAE AND FOLAIR APPLICATION WITH BIO-STIMULATORS AND EFFECT ON VEGETATIVE GROWTH CHARACTERS
...Show More Authors

The current study  was carried out at the Fields belongs of Horticulture  Department, Collage of Agricultural Engineering Science, University of  Baghdad, Al-Jadiriyah for the spring season 2016 -2017 to study the effect for  inoculation mycorrhizae and  folair application  with bio stimulators and their interaction in the growth characters of  (local okra  ptera). A factorial experiment  (2  in randomized complete block design (RCBD), the experiment included (12) treatment  Distributed  in three  replicates. The three factors used in this experiment included . The inoculation with control (C) Mycorrhizae  ( M ) , Biozyme  (B ) ( B1 2cm3.L-1), ( B2 4cm1-.L-1) , Phosphalas (P) (P 2cm3.L-1),  ( M + B1), ( M + B2), (P +

... Show More
Scopus Crossref
Publication Date
Wed Jun 29 2016
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Study the Activity of some plant resources as natural antioxidant: Study the Activity of some plant resources as natural antioxidant
...Show More Authors

This study was done to test the activity of some plant extracts as antioxidant agents. The plants were (Morus rubra, Hibiscus sabdariffa L ., Rhus coriaria L., Anethum graveolens and Petroselinum sativum).
Ethanolic 98% (24 hours/ 25˚c) and distilled water (30 minutes/ 25˚c have been used for extraction.The Total phenols, total flavonoids, total anthocyanin, antioxidant activities were studied.
The extract of Morus rubra was chosen because it has a higher antioxidant activity.
The phenolic extract of Morus rubra was prepare and examined by application it in burger . The antioxidant activity test of Morus rubra was made before and after 3,6 days of cold storage. The sensory evaluation of all treatments were done within 5,1

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 31 2017
Journal Name
Al-khwarizmi Engineering Journal
Preparation of Light Fuel Fractions from Heavy Vacuum Gas Oil by Thermal Cracking Reaction
...Show More Authors

This work deals with thermal cracking of heavy vacuum gas oil which produced from the top of vacuum distillation unit at Al- DURA refinery, by continuous process. An experimental laboratory plant scale was constructed in laboratories of chemical engineering department, Al-Nahrain University and Baghdad University. The thermal cracking process was carried out at temperature ranges between 460-560oC and atmospheric pressure with liquid hourly space velocity (LHSV) equal to 15hr-1.The liquid product from thermal cracking unit was distilled by atmospheric distillation device according to ASTM D-86 in order to achieve two fractions, below 220oC as a gasoline fraction and above 220oC as light cycle o

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Journal Of Applied Spectroscopy
Evaluation of Stability Constant for Vitamin B1 Depending on Stoichiometric Curves by Visible Spectroscopy
...Show More Authors

The measurement of vitamin B1 in pure and pharmaceutical formulations was proposed by using a straightforward and sensitive spectrophotometric approach. Sulfacetamide (SFA) is diazotized, then coupled with vitamin B1 in alkaline media to produce a colored azo dye complex with a stability constant of 5.597 × 105 L/mol. The product is stable, with a maximum absorption wavelength of 489.5 nm, molar absorptivity of 10108 L/mol∙cm, Sandell's sensitivity of 0.0334 μg/cm2, detection limit of 0.0135 μg/mL, and Beer's law being observed over the concentration range of 0.2–20.0 μg/mL. The stability constant and stoichiometry of the produced azo dye were calculated using the continuous variation (Job's) and mole ratio methods. The suggested ap

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Thu Nov 14 2019
Journal Name
Al-kindy College Medical Journal
Risk Of Cancer And Radiation Dose Received By Patients From Common Diagnostic Radiological Examinations
...Show More Authors

Background: Although radiological diagnostic studies (RDS) are an important and acceptable part of medical practice, it is not without hazards. It is associated with increased risk of cancer. Unfortunately the typical and safe dose of each radiological examination is not known. Most of our knowledge of cancer risk comes from studies of survivors of those exposed to whole body radiation from atomic bomb in Hiroshima & Nagasaki, jobs associated with radiation exposure, Chernobyl survivors & patients treated with radiation therapy for cancer and other diseases.

 Objectives   To estimate radiation dose received by patients from diagnostic radiological examinations and lifetime

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 30 2022
Journal Name
Journal Of Economics And Administrative Sciences
Distinguishing Shapes of Breast Cancer Masses in Ultrasound Images by Using Logistic Regression Model
...Show More Authors

The last few years witnessed great and increasing use in the field of medical image analysis. These tools helped the Radiologists and Doctors to consult while making a particular diagnosis. In this study, we used the relationship between statistical measurements, computer vision, and medical images, along with a logistic regression model to extract breast cancer imaging features. These features were used to tell the difference between the shape of a mass (Fibroid vs. Fatty) by looking at the regions of interest (ROI) of the mass. The final fit of the logistic regression model showed that the most important variables that clearly affect breast cancer shape images are Skewness, Kurtosis, Center of mass, and Angle, with an AUCROC of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Sorption of Lead, Zinc and Copper from Simulated Wastewater by Amberlite Ir-120 Resin
...Show More Authors

The presence of heavy metals in the environment is major concern due to their toxicity. In the present study a strong acid cation exchange resin, Amberlite IR 120 was used for the removal of lead, zinc and copper from simulated wastewater. The optimum conditions were determined in a batch system of concentration 100 mg/L, pH range between 1 and 8, contact time between 5 and 120 minutes, and amount of adsorbent was from 0.05 to 0.45 g/100 ml. A constant stirring speed, 180 rpm, was chosen during all of the experiments. The optimum conditions were found to be pH of 4 for copper and lead and pH 6 for zinc, contact time of 60 min and 0.35 g of adsorbent. Three different temperatures (25, 40 and 60°C) were selected to investigate the effect

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Journal Of Engineering
Design, Construction, and Control Tracking of Solar Thermal Concentrator by Using PLC in Erbil
...Show More Authors

This paper demonstrates the construction designing analysis and control strategies for fully tracking concentrated solar thermal by using programmable logic control in the city of Erbil-Iraq. This work used the parabolic dish as a concentrated solar thermal. At the focal point, the collected form of energy is used for heating a (water) in the receiver, analyzing this prototype in real-time with two different shapes of the receiver and comparing the results. For tracking the parabolic dish, four light-dependent resistors are used to detect the sun's position in the sky so that the tracking system follows it to make the beam radiation perpendicular to the collector surface all of the time during the day for maximum solar p

... Show More
View Publication Preview PDF
Crossref