Preferred Language
Articles
/
xYa6t4YBIXToZYALfbP5
Serviceability of Reinforced Concrete Gable Roof Beams with Openings under Static Loads
...Show More Authors

This paper presents an analytical study on the serviceability of reinforced concrete gable roof beams with openings of different sizes, based on an experimental study which includes 13 concrete gable roof beams with openings under static loading. For deflection and crack widths under static loading at service stage, a developed unified calculation procedure has been submitted, which includes prismatic beams with one opening subjected to flexure concentrated force. The deflection has been calculated with two methods: the first method calculated deflections via relevant equations and the second was Direct Stiffness Method in which the beam is treated as a structural member with several segments constituting the portions with solid sections and those with sections crossed by the opening. The crack width was calculated with the ACI code’s equation with a proposed magnification factor equal to 1.125. The analytical results were compared with the experimental ones and a good agreement was obtained.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Studying the Combination Effect of Additives and Micro Steel Fibers on Cracks of Self-Healing Concrete
...Show More Authors

In this study, the effect of the combination of micro steel fibers and additives (calcium hydroxide and sodium carbonate) on the size of cracks formation and healing them were investigated. This study aims to apply the use of self-healing phenomenon to repair cracks and to enhance the service life of the concrete structures. Micro steel fibers straight type were used in this research with 0.2% and 0.4% by volume of concrete. A weight of 20 and 30 kg/m3 of Ca(OH)2 and 2 and 3 kg/m3 of Na2CO3 were used as a partial cement replacement. The results confirm that the concrete cracks were significantly self-healed up to 30 days re-curing. Cracks width up to 0.2 mm were comp

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 20 2020
Journal Name
Fibers
Influence of Cooling Methods on the Behavior of Reactive Powder Concrete Exposed to Fire Flame Effect
...Show More Authors

The construction of highly safe and durable buildings that can bear accident damage risks including fire, earthquake, impact, and more, can be considered to be the most important goal in civil engineering technology. An experimental investigation was prepared to study the influence of adding various percentages 0%, 1.0%, and 1.5% of micro steel fiber volume fraction (Vf) to reactive powder concrete (RPC)—whose properties are compressive strength, splitting tensile strength, flexural strength, and absorbed energy—after the exposure to fire flame of various burning temperatures 300, 400, and 500 °C using gradual-, foam-, and sudden-cooling methods. The outcomes of this research proved that the maximum reduction in mechanical prop

... Show More
View Publication
Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sat Aug 21 2021
Journal Name
Engineering, Technology & Applied Science Research
The Impact of Hybrid Fibers on Punching Shear Strength of Concrete Flat Plates Exposed to Fire
...Show More Authors

This study presents an investigation about the effect of fire flame on the punching shear strength of hybrid fiber reinforced concrete flat plates. The main considered parameters are the fiber type (steel or glass) and the burning steady-state temperatures (500 and 600°C). A total of 9 half-scale flat plate specimens of dimensions 1500mm×1500mm×100mm and 1.5% fiber volume fraction were cast and divided into 3 groups. Each group consisted of 3 specimens that were identical to those in the other groups. The specimens of the second and the third groups were subjected to fire flame influence for 1 hour and steady-state temperature of 500 and 600°C respectively. Regarding the cooling process, water sprinkling was applied directly aft

... Show More
View Publication
Crossref (11)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
The effect of using different fibres on the impact-resistance of slurry infiltrated fibrous concrete (SIFCON)
...Show More Authors
Abstract<p>Slurry infiltrated fibrous concrete (SIFCON) is a modern type of fibre reinforced concrete (FRC). It has unique properties; SIFCON is superior in compressive strength, flexural strength, tensile strength, impact resistance, energy absorption and ductility. Because of this superiority in these characteristics, SIFCON was qualified for applications of special structures, which require resisting sudden dynamic loads such as explosions and earthquakes. The main aim of this investigation is to determine the effect of fibre type on the apparent density of SIFCON and on performance under impact load. In this investigation, hook-end steel fibre and polyolefin fibre were used. Purely once and </p> ... Show More
View Publication
Crossref (4)
Crossref
Publication Date
Sun Feb 01 2026
Journal Name
Journal Of Engineering
Contribution of Fill-Concrete Compressive Strength on the Structural Performance of CFSST Columns: An Analytical Study
...Show More Authors

High-rise structures are a significant indication in contemporary urban improvement, mainly in areas characterized by accelerated urban growth and dense population. This type of building should be designed to withstand severe load conditions. Therefore, using composite structural elements in such structures is required for stronger and durable elements. This paper introduces a finite element analysis model for Concrete Filled Stainless Steel Tubular Columns (CFSST) of (100x100) mm cross-section and (1250) mm length to inspect the impact of concrete compressive strength on the response of (CFSST). The generated model was first evaluated through a comprehensive comparison with experimental research. Then, after the model was used to s

... Show More
View Publication
Scopus Crossref
Publication Date
Wed May 01 2019
Journal Name
Iop Conf. Series: Materials Science And Engineering
Fire flame effect on the compressive strength of reactive powder concrete using different methods of cooling
...Show More Authors

This research foxed on the effect of fire flame of different burning temperatures (300, 400 and 500)oC on the compressive strength of reactive powder concrete (RPC).The steady state duration of the burning test was (60)min. Local consuming material were used to mixed a RPC of compressive strength around (100) MPa. The tested specimens were reinforced by (3.0) cm hooked end steel fiber of (1100) MPa yield strength. Three steel fiber volume fraction were adopted in this study (0, 1.0and 1.5)% and two cooling process were included, gradual and sudden. It was concluding that increasing burning temperature decreases the residual compressive strength for RPC specimens of(0%) steel fiber volume fraction by (12.16, 19.46&24.49) and (18.20, 27.77 &3

... Show More
Scopus (9)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sat Apr 30 2022
Journal Name
Sport Tk-revista Euroamericana De Ciencias Del Deporte
Effect of exercises on the VertiMax device on the endurance of under 16-years of age discus throwers
...Show More Authors

The primary aim of the present study was to prepare a set of exercises on the multi-resistor VertiMax device and to identify the effect of these exercises on the development of the endurance of discus throwers under 16 years old. The design of the present study was experimental. Participants were selected using purposive sampling method. A total of 5 discuss players constituted the sample of the study. The authors found a significant improvement in the levels of endurance and performance as a result of the training on the VertiMax device. Therefore, it is recommendable to use exercises on the VertiMax device to improve the endurance and performance of under 16-years of age discus throwers.

View Publication
Scopus Crossref
Publication Date
Tue Aug 15 2023
Journal Name
Bionatura
Gene expression of a nitrogen tolerance gene ZmNR1 under the influence of different levels of nitrogen in maize
...Show More Authors

A field experiment was carried out in the College of Agricultural Engineering Sciences - University of Baghdad, during the fall season of 2021 to find out which cultivated cultivars of maize are efficient under nitrogen fertilization. The experiment was applied according to an RCBD (split-plot design with three replications). The cultivars of the experiment (Baghdad, 5018, Sarah) supply three levels of nitrogen fertilizer, which are N1 (100 kg.N/ha), N2 (200 kg.N/ha) and N3 (300 kg.N/ha). The statistical analysis results showed the superiority of the Sarah genotype, which gave the highest value of SOD and CAT enzymes, reaching 11.59 units mg-1 and 10.76 units mg-1 . Protein sequentially, while cultivar5018 outperformed as it gave th

... Show More
View Publication
Scopus (15)
Crossref (11)
Scopus Crossref
Publication Date
Thu Aug 01 2019
Journal Name
The Journal Of Solid Waste Technology And Management
Recycling of Waste Compact Discs in Concrete Mix: Lab Investigations and Artificial Neural Networks Modeling
...Show More Authors

This study aimed to investigate the incorporation of recycled waste compact discs (WCDs) powder in concrete mixes to replace the fine aggregate by 5%, 10%, 15% and 20%. Compared to the reference concrete mix, results revealed that using WCDs powder in concrete mixes improved the workability and the dry density. The results demonstrated that the compressive, flexural, and split tensile strengths values for the WCDs-modified concrete mixes showed tendency to increase above the reference mix. However, at 28 days curing age, the strengths values for WCDs-modified concrete mixes were comparable to those for the reference mix. The leaching test revealed that none of the WCDs constituents was detected in the leachant after 180 days. The

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Oct 01 2021
Journal Name
Civil Engineering Journal
Steel Fiber Enhancement upon Punching Shear Strength of Concrete Flat Plates Exposed to Fire Flame
...Show More Authors

In this study, the effect of fire flame on the punching shear strength of steel fiber reinforced concrete flat plates was experimentally investigated using nine half-scale specimens with dimensions of 1500×1500 mm and a total thickness of 100 mm. The main investigated variables comprised the steel fiber volume fraction 0, 1, and 1.5% and the burning steady state temperature 500 and 600 °C. The specimens were divided into three groups, each group consists of three specimens. The specimens in the first group were tested with no fire effect to be the reference specimens, while the others of the second and third groups were tested after being exposed to fire-flame effect. The adopted characteristics of the fire test were; (one hour) b

... Show More
Crossref (3)
Crossref