Preferred Language
Articles
/
xUI4eZoBMeyNPGM31sys
Determination of Cobalt(II) Ion in Various Selected Alloys via Utilizing Continous Flow Injection Analysis ((CFIA) (Nagham-Four Sources of White  Snow LED Arranged in Three Rows Corresponding to Three Detectors Analyzer) (NAG-4SX3-3D)) Analyzer at 0-180o Angle
...Show More Authors

The research study focuses on the efficient and accurate detection and determination of cobalt ions. The detection method involves the formation of brilliant green aggregates with calcium hexacyanoferrate in the presence of nitric acid. (Nagham-four sources of white snow light-emitting diodes arranged in three rows corresponding to three detectors) (The NAG-4SX3-3D Analyzer is an optical, chemical, electronic, and detection tool that receives a cumulative signal (no amplification is required). The total distance travelled is 760 mm with regard to YZ(mV) - tsec (dmm). It was selected for its precise calculation of the energy transducer profile. The linear range for measuring cobalt (II) ions is 0.05 to 20 mM. For concentrations of 5 and 10 mM, the relative standard deviation (RSD) for eight repeated intraday measurements is less than 0.36%. The calibration graph gradually dilutes the lowest concentration to determine the limit of detection (LOD) of 349.236 ng per analyte sample. The correlation coefficient (r) for the linear dynamic range is 0.9893, and the linearity is 97.80% (R2 %).  The results of the proposed method were compared to the already-available UV-spectrophotometric technique at a wavelength of 510 nm and found to be comparable..  

Scopus Crossref
View Publication
Publication Date
Tue Apr 16 2019
Journal Name
Proceedings Of The 2019 5th International Conference On Computer And Technology Applications
Four Char DNA Encoding for Anomaly Intrusion Detection System
...Show More Authors

Recent research has shown that a Deoxyribonucleic Acid (DNA) has ability to be used to discover diseases in human body as its function can be used for an intrusion-detection system (IDS) to detect attacks against computer system and networks traffics. Three main factor influenced the accuracy of IDS based on DNA sequence, which is DNA encoding method, STR keys and classification method to classify the correctness of proposed method. The pioneer idea on attempt a DNA sequence for intrusion detection system is using a normal signature sequence with alignment threshold value, later used DNA encoding based cryptography, however the detection rate result is very low. Since the network traffic consists of 41 attributes, therefore we proposed the

... Show More
View Publication
Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of caries experience, enamel defects and selected salivary biomarkers in children with nutritional rickets
...Show More Authors

Background: Nutritional Rickets is a condition produced by an absence of Vitamin D, calcium or phosphate. It clues to relaxing and fading of the bones. Dental expression of children with rickets contains enamel hypoplasia and delayed tooth eruption. This study was conducted in order to assess caries experience (dmfs) and enamel defects among study and control groups, and to evaluate and compare the levels of selected salivary biomarkers between children with nutritional rickets and apparently healthy children. Material and methods: Assessment of caries according to WHO in 1987, and assessment of enamel defects according to enamel defect index EDI of WHO in 1997. In addition a stimulated saliva samples were collected according to Palone e

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Feb 01 2026
Journal Name
مجلة واسط للعلوم الانسانية
Towards the Aesthetics of Instagram Poetry: Portraying Woman’s Healing Process in Rupi Kaur’s Selected Poems
...Show More Authors

View Publication
Crossref
Publication Date
Thu Dec 10 2009
Journal Name
Iraqi Journal Of Laser
Diagnosis and Treatment of Cervical Intraepithelial Neoplasia with Carbon Dioxide Laser Therapy in Selected Patients
...Show More Authors

Female infection with HPV (human papilla virus) has been established as an essential cause of CIN (cervical intraepithelial neoplasia). The danger of transformation from CIN to frank malignancy should be considered. Objective: The goal of this study is to evaluate the effectiveness of CO2 laser vaporization of ectocervical lesion high grade squamous intraepithelial lesion (HGSIL). Patients and Methods: Four Female out of 150 affected with HGSIL lesions were submitted to CO2 laser vaporization and followed up in 4 months later, and 10 women with HGSIL lesion submitted to electrocautery diathermy for the comparison. Results: Among women treated by CO2 laser vaporization, 3 women had negative results (clear cervix), at 4 months follow up; o

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
Dumping and Its Challenges in Extent of World Trade Organization "Models for selected Agricultural Goods"
...Show More Authors

The subject of dumping is considering today one of the subjects in which form an obstruction arise in front of the cycle of growth for some countries , such as the study of dumping is capturing a large attention by the competent because either a big  role and effect in growing the economies of nations then the subject of dumping became a field turn around its sides many measures and laws … and may be done resorting to by many states of the world to anti-dumping as approach of determent weapon delimit  the impact of dumping and gives the national agriculture sector the opportunity for rising and growing so this section of international economics is capturing a special importance and represent in same time an important

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Azerbaijan Pharmaceutical And Pharmacotherapy J
Evaluation of Nurses’ Practices and Perceived Barriers Related to Pain Assessment in Critically Ill Patients at Baghdad Teaching Hospitals
...Show More Authors

Introduction: Inadequate pain assessment and management is a problem in hospitalized patients that impairs their wellbeing. Intensive care unit nurses’ pain practices are affected by several barriers and enablers. Objectives: The objectives of this study were to determine the level of nurses’ practices and perceived barriers related to pain assessment in critically ill patients. Methodology: A cross-sectional design study was used. Purposive sampling technique was employed, including 100 nurses recruited from 8 intensive care units in Baghdad city, Iraq. The study was conducted from September 1st to October 20th, 2022. The pain assessment and management for critically ill patients survey was used to collect data. Descriptive sta

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (7)
Scopus Crossref
Publication Date
Thu Nov 04 2021
Journal Name
Optik - International Journal For Light And Electron Optics
Plasma parameters of Au nano-particles ablated on porous silicon produced via Nd-YAG laser at 355 nm for sensing NH3 gas
...Show More Authors

The current study aimed the syntheses and characterizations of Gold nanoparticles (Au NPs) using a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the

... Show More
Publication Date
Sat Jan 01 2022
Journal Name
Optik
Plasma parameters of Au nano-particles ablated on porous silicon produced via Nd-YAG laser at 355 nm for sensing NH3 gas
...Show More Authors

a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the rod that appears for Au NPs, in addition to that, TEM has been an indication of the fact that syn

... Show More
View Publication
Scopus (39)
Crossref (34)
Scopus Clarivate Crossref
Publication Date
Fri Jun 01 2012
Journal Name
Journal Of Engineering
Comparative Biosorption Of Pb(II), Cr(III) AND Cd(II) Ions In Single Component System By Live And Dead Anaerobic Biomass, Bath Study
...Show More Authors

In this study, dead and live anaerobic biomass was used in biosorption of Pb(II), Cr(III) and Cd(II) ions from a synthetic wastewater. The biosorption was investigated by batch adsorption experiments. It was found that, the biosorption capacities were significantly affected by biosorbent dosage. The process follows Langmuir isotherm (regression coefficient 0.995, 0.99 and 0.987 for Pb(II), Cr(III) and Cd(II) ions, respectively, onto dead anaerobic biomass) model with uniform distribution over the biomass surface. The experimental uptake capacity was 51.56, 29.2 and 28 mg/g for Pb(II), Cr(III) and Cd(II), respectively, onto dead anaerobic biomass, compared with 35, 13.6 and 11.8 mg/g for Pb(II), Cr(III) and Cd(II), respectively, onto live

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Wave Propagation in Detection of Aorta Dieses Using Lumps Analysis
...Show More Authors

In this paper a theoretical attempt is made to determine whether changes in the aorta diameter at different location along the aorta can be detected by brachial artery measurement.  The aorta is divided into six main parts, each part with 4 lumps of 0.018m length. It is assumed that a desired section of the aorta has a radius change of 100,200, 500%. The results show that there is a significant change for part 2 (lumps 5-8) from the other parts. This indicates that the nearest position to the artery gives the significant change in the artery wave pressure while other parts of the aorta have a small effect.

View Publication Preview PDF