The present study combines UV-Vis spectrophotometry and dispersive liquid-liquid microextraction (DLLME) for the preconcentration and determination of trace level clidinium bromide (Clid) in pharmaceutical preparation and real samples. The method is based on ion-pair formation between Clid and bromocresol green in aqueous solution using citrate buffer (pH = 3). The colored product was first extracted using a mixture of 800 µL acetonitrile and 300 µL chloroform solvents. Then, a spectrophotometric measurement of sediment phase was performed at λ = 420 nm. The important parameters affecting the efficiency of DLLME were optimized. Under the optimum conditions, the calibration graphs of standard -1 (Std.), drug, urine and serum were ranged 0.005 - 0.16 µg mL . The limits of detection, quantification, and Sandell's sensitivity were calculated. Good recoveries of Clid Std., drug, urine and serum at 0.005, 0.01, -1 0.1 and 0.16 µg mL ranged 93.77 - 101.0%. Enrichment factor was calculated for Std., drug, urine and serum. The method was applied successfully to determine Clid in pharmaceutical preparation and real samples.
This case series aims to evaluate patients affected with post COVID‐19 mucormycosis from clinical presentation to surgical and pharmacological treatment to improve the disease prognosis.
This case series was conducted at a specialized surgery hospital in Baghdad Medical City for over 10 months. Fifteen cases who had mild to severe COVID‐19 infections followed by symptoms similar to aggressive periodontitis, such as mobility and bone resorption around the multiple maxillary teeth, were included in this case series.
In this article, a continuous terminal sliding mode control algorithm is proposed for servo motor systems. A novel full-order terminal sliding mode surface is proposed based on the bilimit homogeneous property, such that the sliding motion is finite-time stable independent of the system’s initial condition. A new continuous terminal sliding mode control algorithm is proposed to guarantee that the system states reach the sliding surface in finitetime. Not only the robustness is guaranteed by the proposed controller but also the continuity makes the control algorithm more suitable for the servo mechanical systems. Finally, a numerical example is presented to depict the advantages of the proposed control algorithm. An application in the rota
... Show MoreIn cognitive radio system, the spectrum sensing has a major challenge in needing a sensing method, which has a high detection capability with reduced complexity. In this paper, a low-cost hybrid spectrum sensing method with an optimized detection performance based on energy and cyclostationary detectors is proposed. The method is designed such that at high signal-to-noise ratio SNR values, energy detector is used alone to perform the detection. At low SNR values, cyclostationary detector with reduced complexity may be employed to support the accurate detection. The complexity reduction is done in two ways: through reducing the number of sensing samples used in the autocorrelation process in the time domain and through using the Slid
... Show MoreThis study is dedicated to solving multicollinearity problem for the general linear model by using Ridge regression method. The basic formulation of this method and suggested forms for Ridge parameter is applied to the Gross Domestic Product data in Iraq. This data has normal distribution. The best linear regression model is obtained after solving multicollinearity problem with the suggesting of 10 k value.
The study aims to evaluate the removal of sulfur content from Iraqi light naphtha produced in Al-Dora refinery by adsorption desulfurization DS technique using modified activated carbon MAC loaded with nickel Ni and copper Cu as single binary metals. The experiments were carried in a batch unit with various operating parameters; MAC dosage, agitation speed, and a contact time of 300 min at constant initial sulfur concentration 155 ppm and temperature. The results showed higher DS% by AC/Ni-Cu (66.45)% at 500 rpm and 1 g dosage than DS (29.03)% by activated carbon AC, increasing MAC dosage, agitation speed, and contact time led to increasing DS% values. The adsorption capacity of MAC results was recorded (16,
... Show MoreThis paper represents an experimental study on the application of smart control represented by the use of the fuzzy logic controller. Two-link flexible manipulators that are used in airspace and military applications are made of flexible materials characterized by low frequency and damping ratio. To solve this problem, this paper proposes the use of smart materials (piezoelectric transducers), where each link is bonded with a pair of piezoelectric transducers that act as a sensor and another as an actuator. As the arm vibrates because of the movement generated by the motor, this voltage is controlled by a regulator inside the LABVIEW® 2020 software and sends the output control voltage to the piezoelectric actuator. Experimental results
... Show More