Preferred Language
Articles
/
xBbL3osBVTCNdQwCC-KY
Microvolume-DLLME for the Spectrophotometric Determination of Clidinium Bromide in Drug, Urine, and Serum
...Show More Authors

The present study combines UV-Vis spectrophotometry and dispersive liquid-liquid microextraction (DLLME) for the preconcentration and determination of trace level clidinium bromide (Clid) in pharmaceutical preparation and real samples. The method is based on ion-pair formation between Clid and bromocresol green in aqueous solution using citrate buffer (pH = 3). The colored product was first extracted using a mixture of 800 µL acetonitrile and 300 µL chloroform solvents. Then, a spectrophotometric measurement of sediment phase was performed at λ = 420 nm. The important parameters affecting the efficiency of DLLME were optimized. Under the optimum conditions, the calibration graphs of standard -1 (Std.), drug, urine and serum were ranged 0.005 - 0.16 µg mL . The limits of detection, quantification, and Sandell's sensitivity were calculated. Good recoveries of Clid Std., drug, urine and serum at 0.005, 0.01, -1 0.1 and 0.16 µg mL ranged 93.77 - 101.0%. Enrichment factor was calculated for Std., drug, urine and serum. The method was applied successfully to determine Clid in pharmaceutical preparation and real samples.

Scopus
Publication Date
Thu Feb 01 2024
Journal Name
Baghdad Science Journal
Alpha Tracks Examination for Female Urine Samples who are Suffering from Urinary Tract Infections
...Show More Authors

Urine samples had been gathered from females living in Baghdad city. The sample consisted of 30 females who suffered from U.T.I (Urinary tract infections) and 20 healthy females. The type of urine U.T.I was specified by the emergency lab in Al-Kindy hospital, and alpha tracks were determined by the nuclear track detector CR-39. The concentrations of alpha in 30 urine samples taken from females who had U.T.I ranged from 0.327ppm-1.583ppm, with an average of 0.94965 ppm. The maximum value 1.583 ppm is belonging to females with an aged 57 years old. The results of healthy female concentration ranged from 0.022 ppm-0.459ppm with an average of (0.30855ppm). The findings revealed that alpha emitter concentrations differed from woman to woman,

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Mar 01 2016
Journal Name
Journal Of Natural Sciences Research
Spectrophotometric-Assisted Chemometric Method for the Simultaneous Analysis of Furosemide, Carbamazepine, Diazepam, and Carvedilol in Their Bulk and Marketed Formulation
...Show More Authors

Simultaneous determination of Furosemide, Carbamazepine, Diazepam, and Carvedilol in bulk and pharmaceutical formulation using the partial least squares regression (PLS-1 and PLS-2) is described in this study. The two methods were successfully applied to estimate the four drugs in their quaternary mixture using UV spectral data of 84synthetic mixtures in the range of 200-350nm with the intervals Δλ=0.5nm. The linear concentration range were 1-20 μg.mL-1 for all, with correlation coefficient (R2) and root mean squares error for the calibration (RMSE) for FURO, CARB, DIAZ, and CARV were 0.9996, 0.9998, 0.9997, 0.9997, and 0.1128, 0.1292, 0.1868,0.1562 respectively for PLS-1, and for PLS-2 were 0.9995, 0.9999, 0.9997, 0.9998, and 0.1127, 0.

... Show More
Publication Date
Tue Feb 01 2022
Journal Name
Baghdad Science Journal
Study the Inhibition Effect of Amoxicillin Drug for Corrosion of Carbon Steel in Saline Media
...Show More Authors

          Potentiostatic polarization and weight loss methods have been used to investigate the corrosion behavior of carbon steel in sodium chloride solution at different concentrations (0.1, 0.4 and 0.6) M under the influence of temperatures ( 293, 298, 303, 308 and 313) K. The inhibition efficiency of the amoxicillin drug on carbon steel in 0.6 M NaCl has also been studied based on concentration and temperature. The corrosion rate showed that all salt concentrations ( NaCl solution) resulted in corrosion of carbon steel in varying ratio and 0.6 M of salt solution  was the highest rate (50.46 g/m².d). The results also indicate that the rate of corrosion increases at a temperature of 313 K.. Potentiodynamic polarization studi

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process
...Show More Authors

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Primary Diagnosis of Abnormal Urine via Auto Fluorescence Process
...Show More Authors

The main objective of this study is to determine the suitable excitation wavelengths for
urine components reaching to select the suitable lasers to execute the auto fluorescence due to their
high intensities. The auto fluorescence was measured at 305, 325 and 350 nm excitation wavelengths
for eleven urine samples which were also analyzed by conventional methods (chemical and
microscopic examination). Data manipulation using Matlab package programming language showed
that urine sample with normal chemical and biological components have emission peaks which are
different from the infected urine samples. Despite the complexity of the composition of urine,
fluorescence maxima can be observed. Most likely, the peaks obser

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 30 2025
Journal Name
Studia Universitatis Babeș-bolyai Chemia
GREEN SPECTROPHOTOMETRIC METHOD FOR CONCURRENT ESTIMATION OF PIROXICAM AND MEFENAMIC ACID MIXTURE
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Sun Mar 30 2025
Journal Name
Studia Universitatis Babeș-bolyai Chemia
GREEN SPECTROPHOTOMETRIC METHOD FOR CONCURRENT ESTIMATION OF PIROXICAM AND MEFENAMIC ACID MIXTURE
...Show More Authors

The purpose of this work is to concurrently estimate the UVvisible spectra of binary combinations of piroxicam and mefenamic acid using the chemometric approach. To create the model, spectral data from 73 samples (with wavelengths between 200 and 400 nm) were employed. A two-layer artificial neural network model was created, with two neurons in the output layer and fourteen neurons in the hidden layer. The model was trained to simulate the concentrations and spectra of piroxicam and mefenamic acid. For piroxicam and mefenamic acid, respectively, the Levenberg-Marquardt algorithm with feed-forward back-propagation learning produced root mean square errors of prediction of 0.1679 μg/mL and 0.1154 μg/mL, with coefficients of determination of

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Wed Mar 07 2018
Journal Name
International Journal Of Applied Pharmaceutics
FORMULATION AND CHARACTERIZATION OF LAFUTIDINE NANOSUSPENSION FOR ORAL DRUG DELIVERY SYSTEM
...Show More Authors

Objective: The objective of this study was to prepare nanosuspension of a practical water insoluble antiulcer drug which is lafutidine to enhance the solubility, dissolution rate with studying the effect of different formulation variables to obtain the best formula with appropriate physical properties and higher dissolution rate.Methods: Nanosuspension of lafutidine was prepared using solvent anti-solvent precipitation method using Polyvinylpyrrolidone K-90(PVP K-90) as the stabilizer. Ten formulations were prepared to show the effect of different variables in which two formulations showed the effect of stabilizer type, three formulations showed the effect of stabilizer concentration, two formulations showed the effect of combinatio

... Show More
View Publication
Scopus (26)
Crossref (13)
Scopus Crossref
Publication Date
Tue Mar 22 2016
Journal Name
Iraqi Journal Of Medical Sciences
BK Polyomavirus-infected Decoy Cells in Urine Cytology Specimens of Renal Transplant Recipients
...Show More Authors

Background BK polyomavirus is one of the common post-transplant viral infections, affecting ∼15% of renal transplantation recipients (RTR), leading to graft loss in more than half of cases. Objectives Study the rate of detection of BK virus (BKV) in RTRs in Pap-stained urine cytology specimens. Methods A single center study, urine samples were collected from 99 RTR patients, with 15 Living Donors (LD) and 15 patients with chronic kidney disease (CKD) were taken as controls. And urine cytology smears were Pap stained for detection of decoy cells (DCs). Results Out of the 99 RTRs, 27 (27.3%) patients were decoy positive, 8 out of these 27 patients had uncommon DCs, and 5 out of these 27 cytology positive patients (18.5%) had biopsy proven B

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine & Public Health
Newly developed method for determination of methyldopa drug using ammonium ceric (IV) nitrate by continuous flow injection analysis via homemade NAG-ADF-300-2 analyser
...Show More Authors

A new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n

... Show More
Crossref (2)
Crossref