Despite not being digested, trace elements and/or heavy metals are important for the activity of enzymes, physiological processes, and homeostasis. If certain trace elements are present in excess, they can have harmful effects and pose major health hazards. Objective: The aims to examine the connection between serum zinc, copper levels, and the Cu/Zn ratio, and several anthropometric parameters, including an index of body mass and the waist-hip ratio. In our study, we used atomic absorption spectrometry (AAS) to measure serum levels of copper (Cu) and zinc (Zn) in 60 individuals, 30 patients with kidney cancer and 30 healthy controls. We assessed serum uric acid, creatinine, and urea using the semi-auto analyzer BA-88A (Korea). The results revealed a highly significant in the level of serum Cu, Zn and Cu/Zn ratio when compared with control, additionally high significant elevation in serum uric acid, creatinine and urea when compared with control. The result also indicates a prevalence of body mass index (BMI) and waist-hip-ratio (WHR) in patients with kidney cancer when compared with control. Our study compares blood levels of copper (Cu) and zinc (Zn) in kidney cancer patients to those in healthy controls. We aim to investigate any differences in the prevalence of these trace elements between the two groups, additionally of that a good relationship between BMI and WHR with serum Cu and Zn in the patient with kidney cancer. Current data reveal a significant prevalence of altered levels of copper (Cu), zinc (Zn), and the Cu/Zn ratio in patients with kidney cancer

The present study was conducted to estimate the antimicrobial activity and the potential biological control of the killer toxin produced by
The study of entry and reentry dynamics for space vehicles is very important, particularly for manned vehicles and vehicles which is carry important devices and which can be used again. There are three types for entry dynamic, ballistics entry, glide entry and skip entry. The skip entry is used in this work for describing entry dynamics and determining trajectory. The inertia coordinate system is used to derive equations of motion and determines initial condition for skip entry. The velocity and drag force for entry vehicle, where generate it during entry into earth’s atmosphere are calculated in this work. Also the deceleration during descending and determining entry angles, velocities ratio and altitude ratio have been studied. The c
... Show MoreAbstract: Tin oxide thin films were deposited by direct current (DC) reactive sputtering at gas pressures of 0.015 mbar – 0.15 mbar. The crystalline structure and surface morphology of the prepared SnO2 films were introduced by X-ray diffraction (XRD) and atomic force microscopy (AFM). These films showed preferred orientation in the (110) plane. Due to AFM micrographs, the grain size increased non-uniformly as the working gas pressure increased.
Most available methods for unit hydrographs (SUH) derivation involve manual, subjective fitting of
a hydrograph through a few data points. The use of probability distributions for the derivation of synthetic
hydrographs had received much attention because of its similarity with unit hydrograph properties. In this
paper, the use of two flexible probability distributions is presented. For each distribution the unknown
parameters were derived in terms of the time to peak(tp), and the peak discharge(Qp). A simple Matlab
program is prepared for calculating these parameters and their validity was checked using comparison
with field data. Application to field data shows that the gamma and lognormal distributions had fit well.<
Nanostructure of chromium oxide (Cr2O3-NPs) with rhombohedral structure were successfully prepared by spray pyrolysis technique using Aqueous solution of Chromium (III) chloride CrCl3 as solution. The films were deposited on glass substrates heated to 450°C using X-ray diffraction (XRD) shows the nature of polycrystalline samples. The calculated lattice constant value for the grown Cr2O3 nanostructures is a = b = 4.959 Å & c = 13.594 Å and the average crystallize size (46.3-55.6) nm calculated from diffraction peaks, Spectral analysis revealed FTIR peak characteristic vibrations of Cr-O Extended and Two sharp peaks present at 630 and 578 cm-1 attributed to Cr-O “stretching
... Show More