In this paper, a time–space fractional order inverse source problem to determine the temperature solution and the time‐dependent source term from heat moment to the time–space fractional heat equation with an initial condition, homogeneous Dirichlet boundary conditions, and integral overdetermination condition is investigated. Two unconditionally stable finite difference schemes are proposed to find a numerical solution of the direct problem. Namely, method I is based on the approximation of the time‐fractional derivative via Laplace transformation, whereas method II is based on finite difference approximation. The inverse problem is solved iteratively
That the electronic payments system plays an important role in the effectiveness of commercial banks by attracting domestic or foreign investors, especially in the banking sector , It must keep abreast of global developments and technology in the field of banking that lead to the effectiveness of the bank by providing modern banking services and good customer service that improves the reputation of the bank, as well as develop its activities and promotes economic development at the country level , The technological progress of the bank will increase the speed of conducting banking operations, accuracy and safer , here should be laws and regulations related to electronic payment systems keep pace with the la
... Show MoreExperimental tests were conducted to investigate the thermal performance (cooling effect) of water mist system consisting of 5μm volume median diameter droplets in reducing the heat gain entering a room through the roof and the west wall by reducing the outside surface temperature due to the evaporative cooling effect during the hot dry summer of Baghdad/Iraq. The test period
was Fifty one days during the months May, June, and July 2012. The single test day consists of 16 test hours starting from 8:00 am to 12:00 pm. The results showed a reduction range of 1.71 to 15.5℃ of the roof outside surface temperature and 21.3 to 76.6% reduction in the daily heat flux entering the room through the roof compared with the case of not using w
Numerical simulations have been carried out on the solar chimney power plant systems. This paper gives the flow field analysis for a solar chimney power generation project located in Baghdad. The continuity, Naver-stockes, energy and radiation transfer equations have been solved and carried out by Fluent software. The governing equations are solved for incompressible, 3-D, steady state, turbulent is approximated by a standard k - model with Boussiuesq approximation to study and evaluate the performance of solar chimney power plant in Baghdad city of Iraq. The different geometric parameters of project are assumed such as collector diameter and chimney height at different working conditions of solar radiation intensity (300,450,600,750
... Show MoreA Field experiment was conducted in Horticulture and Landscape Department, College of Agricultural Engineering Sciences, University of Baghdad, Al-Jadriah during fall 2019-2020 to study changes in the growth and yield of broccoli grown in the alternative solution ABEER, affected by gas enrichment and spraying with coconut water and moringa aqueous extract under the hydroponic cultivation system. Nested design with three replications adopted in the experiment, each of them included in main plot the first factor, which is gas enrichment (O2 and O3), Then levels of second factor were randomly distributed within each replicate, which included spra
In this research a recent developed practical modeling technique is applied for the glucose regulation system identification. By using this technique a set of mathematical models is obtained instead of single one to compensate for the loss of information caused by the optimization technique in curve fitting algorithms, the diversity of members inside the single set is interpreted in term of restricted range of its parameters, also a diagnosis criteria is developed for detecting any disorder in the glucose regulation system by investigating the influence of variation of the parameters on the response of the system, this technique is applied in this research practically for 20 cases with association of National Center for
... Show MoreAs a result of the entry of multinationals companies in Iraq for investing in the joint projects through conducting agreements and contracts for work on important and strategic projects to get the necessary funds and various experiences which characterize the foreign participant sides that Iraq currently needs them and because of the non-applying the accounting processing stipulated in the unified accounting system in addition to the absence of a local accounting bases as well as the default of the participant contracts on indicating the accounting methods about those projects which are considered one of the bases that enables auditors in the public sector to depend on it, thus the research paper deals with studying an
... Show MoreArabic calligraphy is one of the greatest achievements of Islamic art. The visual form of Arabic calligraphy is the primary means of presenting ideas and messages for expressive communication in Arabic typefaces. Emerging computer technology with calligraphy is essential for effective visual designs; however, traditional typefaces are insufficient in number and quality to fulfill the requirements of the current Saudi industry. Thus, this research investigates the processes followed by graphic designers to create modern Arabic type designs inspired by Arabic calligraphy, and presents the characteristics of Arabic calligraphy. The research implemented a mixed experimental and descriptive method, exploring 10 typefaces designed by professio
... Show MoreThermal energy storage is an important component in energy units to decrease the gap between energy supply and demand. Free convection and the locations of the tubes carrying the heat-transfer fluid (HTF) have a significant influence on both the energy discharging potential and the buoyancy effect during the solidification mode. In the present study, the impact of the tube position was examined during the discharging process. Liquid-fraction evolution and energy removal rate with thermo-fluid contour profiles were used to examine the performance of the unit. Heat exchanger tubes are proposed with different numbers and positions in the unit for various cases including uniform and non-uniform tubes distribution. The results show that
... Show More