Preferred Language
Articles
/
whYixIsBVTCNdQwC6NxY
Using User Experience Metrics for Academic Management System of University of Baghdad
...Show More Authors

Interface evaluation has been the subject of extensive study and research in human-computer interaction (HCI). It is a crucial tool for promoting the idea that user engagement with computers should resemble casual conversations and interactions between individuals, according to specialists in the field. Researchers in the HCI field initially focused on making various computer interfaces more usable, thus improving the user experience. This study's objectives were to evaluate and enhance the user interface of the University of Baghdad's implementation of an online academic management system using the effectiveness, time-based efficiency, and satisfaction rates that comply with the task questionnaire process. We made a variety of interfaces for the system's interface and selected the best ones based on the study's findings. This study will show how user-friendly our interface will be for those with little to no computer experience. 24 participants participated in the usability testing to evaluate the system's functionality. The results demonstrate excellent usability with a participation error rate of 33.3% and an efficacy rate of 71.43%. Furthermore, some suggestions are given for enhancing our university system's human-computer interaction metrics.

Scopus Crossref
View Publication
Publication Date
Fri Sep 30 2022
Journal Name
Industrial Engineering & Management Systems
Optimizing the Complex Systems Reliability Using Mixed Strategy in Ultra-fast Gas Turbine Protection System
...Show More Authors

View Publication
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Sep 01 2008
Journal Name
Al-khwarizmi Engineering Journal
Correcting Working Postures in Water Pump Assembly Tasks using the OVAKO Work Analysis System (OWAS)
...Show More Authors

Ovako Working Postures Analyzing System (OWAS) is a widely used method for studying awkward working postures in workplaces. This study with OWAS, analyzed working postures for manual material handling of laminations at stacking workstation for water pump assembly line in Electrical Industrial Company (EICO) / Baghdad. A computer program, WinOWAS, was used for the study. In real life workstation was found that more than 26% of the working postures observed were classified as either AC2 (slightly harmful), AC3 (distinctly harmful). Postures that needed to be corrected soon (AC3) and corresponding tasks, were identified. The most stressful tasks observed were grasping, handling, and positioning of the laminations from workers. The construct

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 01 2017
Journal Name
Applied Energy
Melting enhancement in triplex-tube latent heat energy storage system using nanoparticles-metal foam combination
...Show More Authors

View Publication
Scopus (275)
Crossref (269)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Iraqi Journal Of Science
Diagnoses System of Varicose Disease
...Show More Authors

The diagnoses system of varicose disease has a good level of performance due to the complexity and uniqueness in patterns of vein of the leg. In addition, the patterns of vein are internal of the body, and its features are hard to duplicate, this reason make this method not easy to fake, and thus make it contains of a good features for varicose disease diagnoses. The proposed system used more than one type of algorithms to produce diagnoses system of varicose disease with high accuracy, in addition, this multi-algorithm technique based on veins as a factor to recognize varicose infection. The obtained results indicate that the design of varicose diagnoses system by applying multi- algorithms (Naïve Bayes and Back-Propagation) produced new

... Show More
Publication Date
Tue Jun 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of Hoisting System Performance
...Show More Authors

In this paper it is required to enhance the performance of a mechanical system (here: a Hoisting System) where it is preferred to lift a different payloads with approximately the same speed of lifting and keeping at the same time the good performance, and this of course needs some intelligence of the system which will be responsible on measuring the present load and taking into account the speed and performance desired in order to achieve the requirements or the criteria. The process therefore is a Mechatronics System design which includes a measuring system, a control or automation technique, and an actuating system. The criteria built here in this research using a given Hoist system's characteristics and parameters and changing one of

... Show More
View Publication Preview PDF
Publication Date
Thu Aug 04 2022
Journal Name
Contemporary Nurse
ICU nurses’ safety performance related to respect for safety and management commitment: A cross-sectional study
...Show More Authors

View Publication
Scopus (13)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Soil Science Society Of America Journal
Agroforestry, grass, biofuel crop, and row‐crop management effects on soil water dynamics for claypan landscapes
...Show More Authors

Soil water use and water storage vary by vegetative management practices, and these practices affect land productivity and hydrologic processes. This study investigated the effects of agroforestry buffers (AB), grass buffers (GB), and biofuel crops (BC), relative to row crops (RC) on soil water use for a claypan soil in northern Missouri, USA. The experiment located at the Greenley Memorial Research Center included RC, AB, GB, and BC established in 1991, 1997, 1997, and 2012, respectively. Soil water reflectometer sensors installed at 5‐, 10‐, 20‐, and 40‐cm depths monitored soil water from April to November in 2017 and 2018. Results showed significant differences in weekly volumetric water content (VWC) among treatments for all fou

... Show More
View Publication
Scopus (9)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Wed Oct 07 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
CA 27-29: A Valuable Marker for Breast Cancer Management in Correlation with CA 15-3
...Show More Authors

View Publication
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
High Order Sliding Mode Observer-Based Output Feedback Controller Design For Electro-Hydraulic System
...Show More Authors

A perturbed linear system with property of strong observability ensures that there is a sliding mode observer to estimate the unknown form inputs together with states estimation. In the case of the electro-hydraulic system with piston position measured output, the above property is not met. In this paper, the output and its derivatives estimation were used to build a dynamic structure that satisfy the condition of strongly observable. A high order sliding mode observer (HOSMO) was used to estimate both the resulting unknown perturbation term and the output derivatives. Thereafter with one signal from the whole system (piton position), the piston position make tracking to desire one with a simple linear output feedback controller after ca

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study of Drug Delivery system for Prednisolone Loaded and Released by Mesoporous Silica MCM-41
...Show More Authors

In the present study, nanoporous material type MCM-41 was prepared by the sol-gel technique and was used as a carrier for prednisolone (PRD) drug delivery. The structural properties of mesoporous were fully characterized by X-ray diffraction (XRD), N2 adsorption /desorption and Fourier-transform infrared (FTIR). The mass transfer in term of adsorption process (loading) and desorption process (releasing) properties were investigated. The maximum drug loading efficiency was equal to 38% and 47.5% at different concentrations. The PRD released was prudently studied in water media of pH 6.8 simulated body fluid (SBF) in according to "United State Pharmacopeia (USP38)". The results proved that the release of prednisolone from MCM-41

... Show More
View Publication Preview PDF