The objective of this study was to investigate the drought stress and plant density possibility on water productivity and grain yield of maize (Zea mays L.) (Planting Baghdad 3 synthetic varieties), Field experiment was conducted at Abu Ghraib Research Station (Baghdad) during spring and Autumn seasons of 2016 using a randomized complete block design arranged in split plot with three replications. Three irrigation treatment included: irrigation after depletion 50% of available water (T1), irrigation after depletion 75% of available water (T2) and irrigation after depletion 90% of available water (T3) in the main plots and three plant density which were: 1 seeds hill-1 (D1) giving a uniform plant density of 66666 plants ha-1 , 2 seeds hill1 (D2) giving a uniform plant density of 133332 plants ha-1 and 3 seeds hill-1 (D3) giving a uniform plant density of 266664 plants ha-1 assigned in sub plots. The results showed that the plant density of 66666 plants ha-1 gave highest value for most growth and yield components (day's number to 50% male and female flowering, leaf area, dry matter for root and number of ears per plant) for both seasons, but no significant with plant density of 133332 plants ha-1 . Irrigation at depletion 75% of available water was superior in grain yield and most components of growth, also this treatment not significant compare with irrigation at depletion 50% of available water in all parameter of growth and yield of corn. Irrigation at depletion 75% of available water was saving 21.5 and 12.23% depth of water added compare to irrigation at depletion 50% of available water in spring and autumn season, respectively. The irrigation at depletion 75% of available water gave the highest grain yield 9356 kg ha-1 and plant density D1 gave the highest value 8449 kg ha-1 and not difference with D2 8278 kg ha-1 , but increased compare to D3 treatment.
Hydrogeological investigation and water budget calculation of Koi Sanjaq basin is carried out. This investigation includes the determination of the aquifer types extending through the study area and flow direction as well as aquifer hydraulic properties values. Three main unconfined aquifer types were distinguished , they are (Pilaspi), , (Bihassan-Muqdadiya and Fatha –Injana) Formations , where the flow map of the unconfined aquifers shows that the flow direction is from northern and northeastern parts towards the south and southeastern parts i.e. .Lesser Zab River. Analysis of pumping test data of 9 selected wells from unconfined aquifers show that T values range from 1.51m2/day to 64.4 m2/day revealing the great variations in the aq
... Show MoreThe experiment was carried out in the green house of botanical garden belong to Department of Biology/College of Education for Pure Science Ibn AL-Haitham, University of Baghdad for growing season 2017-2018 to evaluate effect of lead stress with concentrations (0, 50, 100, 150) mg.L -1 and Selenium concentrations (0, 15, 30) mg.L-1 on growth of dill plant using pots. The experiment was designed according to completely randomized design (CRD) with three replications. Result indicated that dill plants subjected to lead stress with height concentrations caused decrease in plant parameters (plant height, no. of branches. plant-1, root length, shoot dry weight, the content of nitrogen, phosphorus and potassium, protein concentration, no. of umbe
... Show MoreThis research deals with analyzing samples of water from the Euphrates River before and after (50m, 200m, 500m, and 1000m from the outflow)the power plant of AL-Musayyab. A Water Quality Index (WQI) analysis was performed, which is a helpful tool for rapid estimation of the quality of any water resource.. Water quality of the river was classified into good, poor, very poor, and unsuitable for drinking, based on physico-chemical parameters such as pH, total hardness (TH), and concentrations of the major ions of calcium (Ca+2), sodium (Na+), magnesium (Mg+2), potassium (K+), nitrate (NO3-2), sulphate (SO4-2), phosphate (PO4-2), and Chloride (Cl-),
... Show MoreIn this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended use as well as indicating pollution, which are useful in water quality management and decision making. The application of Water Quality Index (WQI) with ten physicochemical water quality parameters was performed to evaluate the quality of Euphrates River water for drinking usage. This was done by subjecting the water samples collected from seven stations within Al-Anbar province during the period 2004-2010 to comprehensive physicochemical analysis. The ten physicochemical parame
... Show MoreIn this study water quality was indicated in terms of Water Quality Index that was determined through summarizing multiple parameters of water test results. This index offers a useful representation of the overall quality of water for public or any intended
use as well as indicating pollution, which are useful in water quality management and decision making. The application of Water Quality Index (WQI) with ten physicochemical water quality parameters was performed to evaluate the quality of Euphrates River water for drinking usage. This was done by subjecting the water samples collected from seven stations within Al-Anbar province during the period 2004-2010 to comprehensive physicochemical analysis. The ten physicochemical paramete
To achieve optimal plant growth and production under salt stress, some products were added in adequate quantities to give a good yield, especially bean plants which are sensitive to salinity. For this purpose, this experiment was carried out during the spring growing season in 2022 in Baghdad, to study the effects of humic acid, cytokinin, arginine and their interaction with 9 parameters that reflect the overall traits of vegetative growth and yield of common bean plants Phaseolus vulgaris L. var. Astraid (from MONARCH seeds, China). The factorial design with 3 replicates was used, each with 7 plants treated via foliar spraying or by addition to the soil. The first factor included three groups; H0, H1 and H2 (0, 6, 12 Kg.h-1 H
... Show MoreThis study was carried out at University of Baghdad - College of Agricultural Engineering Sciences - Research Station B during the autumn season 2019-2020, in order to evaluate the effect of Ozone and the foliar application of coconut water and moringa extract on the growth of broccoli plant grown in modified NFT film technology. A factorial experiment (2*5) was carried out within Nested Design with three replicates. The ozone treatment was distributed into the main plots which consisted of oxygen (O2) and ozone (O3). The foliar application of organic nutrients were distributed randomly within each replicate including five treatments, which were the control treatment (T0), Coconut water with two concentrations of 50 (T1) and 100 ml.
... Show MoreBacteriological characteristics of Tigris river water were assessed monthly to monitor the impact of pollutants of Medical City waste water for the period from January to June-2013. Four stations were selected for the study, the first station placed before the Medical City Complex (500 meters). The second station represent Medical City sewage discharge into the river, where represents the study area. The third station placed (500 meters) after the second station, and the forth station is located on (2000 meters) after the second station.
Samples collected monthly to monitor the changes of water indicators showed that: Total Bacterial Count (10000 to 2700000 cells/1 ml), Total Coliform (200-3700 cells/100 ml), Fecal Coliform (100-2400
The discharged water from tannery plants is main source for pollution of soil and groundwater, especially in Nahrawan area. Water samples is collected from 10 sites of wells, discharged water and from using water in different levels of tannery and 7 soil samples from different sites inside factories area and outside it. The results shown that pH for samples of wells and discharged water were within allowable limits between 6.5- 8.5, except the value of pH recorded in the discharged water sample (after the addition of calcium hydroxide) was 12.8, as well as reached the highest value of total dissolved salts (TDS) 7800 ppm in same samples. It also reached its highest value of electrical conductivity (EC) 8200 μS/cm. The results showed tha
... Show More