After baking the flour, azodicarbonamide, an approved food additive, can be converted into carcinogenic semicarbazide hydrochloride (SEM) and biurea in flour products. Thus, determine SEM in commercial bread products is become mandatory and need to be performed. Therefore, two accurate, precision, simple and economics colorimetric methods have been developed for the visual detection and quantitative determination of SEM in commercial flour products. The 1st method is based on the formation of a blue-coloured product with λmax at 690 nm as a result of a reaction between the SEM and potassium ferrocyanide in an acidic medium (pH 6.0). In the 2nd method, a brownish-green colored product is formed due to the reaction between the SEM and phosphomolybdic acid (PMA) in a basic medium (pH 9.0). The resulting product absorbs light at λmax 750 nm. The colorimetric methods can be used either as sensors to detect the SEM by bare eye observation as little as 10 ppm and 2.0 ppm within 4−2 min or by spectrophotometry as the determination methods with linearity ranges 8.0−180 ppm and 0.5−30 ppm for the 1st and 2nd methods respectively. The developed methods were successfully applied to determine the SEM in the commercial bread products with a relative standard deviation (RSD) <3 %, <2 % and recovery of 94–103 %, 96–101 % for methods (1st and 2nd) respectively. The visual detection limits of the sensors can be used as a platform for SEM field-portable detection due to their lower limitations than the reported SEM in flour products, which opens the doors for on-site detection of SEM with instrument free.
A sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.
The research focuses on determination of best location of high elevated tank using the required head of pump as a measure for this purpose. Five types of network were used to find the effect of the variation in the discharge and the node elevation on the best location. The most weakness point was determined for each network. Preliminary tank locations were chosen for test along the primary pipe with same interval distance. For each location, the water elevation in tank and pump head was calculated at each hour depending on the pump head that required to achieve the minimum pressure at the most weakness point. Then, the sum of pump heads through the day was determined. The results proved that there is a most economical lo
... Show MoreA UV-Vis spectrophotometry method was developed for the determination of metoclopramide hydrochloride in pure and several pharmaceutical preparations, such as Permosan tablets, Meclodin syrups, and Plasil ampoules. The method is based on the diazotization reaction of metoclopramide hydrochloride with sodium nitrate and hydrochloric acid to yield the diazonium salt, which is then reacted with 3,5-dimethyl phenol in the presence of sodium hydroxide to form a yellow azo dye. Calibration curves were linear in the range from 0.3 to 6.5 µg/mL, with a correlation coefficient of 0.9993. The limits of detection and quantification were determined and found to be 0.18 and 0.61 µg/mL, respectively. Accuracy and precision were also determined b
... Show MoreA simple, rapid and sensitive spectrophotometric method has been developed for the determination of captopril in aqueous solution. The method is based on reaction of captopril with 2,3-dichloro 1,4- naphthoquinon(Dichlone) in neutral medium to form a stable yellow colored product which shows maximum absorption at 347 nm with molar absorptivity of 5.6 ×103 L.mole-1. cm-1. The proposed method is applied successfully for determination of captopril in commercial pharmaceutical tablets.
New membrane electrodes for determination of ciprofloxacin hydrochloride were prepared depending on ciprofloxacin hydrochloride - phosphotungstic acid (CFH-PT) as an active material and these electrodes were made with three plasticizers: Di-octylphenylphosphonate(DOPH), Di-butyl phosphate (DBP)Tri-n-butyl phosphate(TBP), in PVC matrix. One of the ciprofloxacin electrodes was gave Nernstian slope equal to 57.21 mV/ decade for DOPH membrane with concentration range from 1.5×10-5 to1.0×10-1 M, and detection limit equal to 1.5×10-6 M .Lifetime was 93 days. Non- Nernstian responses equal to 39.40 and 30.70 mV/ decade for membranes DBP, TBP, respectively. These electrodes were gave concentration range from 1.0× 10-5 to 1.0×10-2 and from 4.0
... Show MoreThe research aims at identifying the extent to which the top management in the organization is interested in managing the talents of its employees, through which it can face the competing organizations, as well as the great challenges faced by all organizations in recent years. The task of attracting and maintaining talented human resources is one of the biggest challenges facing Organizations
... Show More
The research aims at measuring the impact of visual media on the development of the tourism services sector, which is a field study for the public. It aims at determining the impact of visual media on tourism sector development, clarifying the concept of visual media and its functions and studying the role of media in the development of tourism culture among the public. For a sample of the employees of the University of Baghdad, consisting of (120) male and female. A questionnaire was prepared for this purpose consisting of (21) questions distributed to the sample. The data were analyzed and the hypotheses were tested using the statistical program spss to unload the results and calculate the frequencies, percentages and correlati
... Show MoreIn this study, phosphorescence analysis (KPA) is used for determining soil collected from the Tigris River from Al- Karrada and Bab Al-Sharq in Baghdad and samples were taken from rainwater collected from Al-Rashad, Al-Obeidi, Al-Dora and Al-Sadr City in Baghdad. The measurements were carried out by the Iraqi Ministry of Health and Environment, in the Radiation Protection Center. The collection, removal and evaporation of the samples ranged from January to the end of March 2018. The results show the presents of concentration of 238U and 235U in soil samples and the rainwater samples. The conclusion of this work is the concentration of uranium in soil samples is more than recommendations by ICRP value of 1.9 μg /l. While all water sample
... Show MoreThis research deals with the use of a number of statistical methods, such as the kernel method, watershed, histogram and cubic spline, to improve the contrast of digital images. The results obtained according to the RSME and NCC standards have proven that the spline method is the most accurate in the results compared to other statistical methods