Preferred Language
Articles
/
vxg16ZQBVTCNdQwCNSJ4
Correlation between plasma homocysteine and ischemic heart disease in young Adults
...Show More Authors

Background Cardiovascular disease (CVD) is a leading cause of death worldwide. Ischemic heart disease is a major cause of morbidity and mortality. Lack of blood supply to the brain can cause tissue death if any of the cerebral veins, carotid arteries, or vertebral arteries are blocked. An ischemic stroke describes this type of event. One of the byproducts of methionine metabolism, the demethylation of methionine, is homocysteine, an amino acid that contains sulfur. During myocardial ischemia, the plasma level of homocysteine (Hcy) increases and plays a role in many methylation processes. Hyperhomocysteinemia has only recently been recognized as a major contributor to the increased risk of cardiovascular disease (CVD) owing to its effects on atherothrombosis and improvement of oxidative stress-induced endothelial dysfunction, joining the ranks of other known risk factors such as hyperlipidemia, hypertension, diabetes, and advanced age. Objective The purpose of this study was to determine whether there is a relationship between elevated serum total homocysteine (tHcy) levels and an increased risk of coronary artery disease (CAD) in an Iraqi population of patients with ischemic heart disease. Methods This study was conducted at Madinat al-Imamain Al Kadhmain Hospital’s Cardiology Department in Baghdad, Iraq. The study lasted for six months and was designed as an observational case-control study from November 1, 2023, to April 1, 2024. Results Cases and controls had similar characteristics but differed significantly in serum homocysteine concentration. The mean homocysteine level in case group was 40.21±14.47 mmol/L and 9.23±2.41 mmol/L in control group with p value <0.001. Conclusion In young individuals, hyperhomocysteinemia is positively associated with coronary artery, even when other traditional risk factors are not present.

Crossref
View Publication
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
The study of thermal description for non-thermal plasma needle system
...Show More Authors

Cold plasma is a relatively low temperature gas, so this feature enables us to use cold plasma to treat thermally sensitive materials including polymers and biologic tissues. In this research, the non-thermal plasma system is designed with diameter (3 mm, 10 mm) Argon at atmospheric pressure as well as to be suitable for use in medical and biotechnological applications.
The thermal description of this system was studied and we observed the effect of the diameter of the plasma needle on the plasma, when the plasma needle slot is increased the plasma temperature decrease, as well as the effect of the voltages applied to the temperature of the plasma, where the temperature increasing with increasing the applied voltage . Results showed t

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Iraqi Journal Of Physics
Investigate Indian Costus Plasma Parameters using Q-Switched Laser Nd: YAG
...Show More Authors

The Indian costus plasma properties are investigated including electron temperature (Te), "electron density (ne)", "plasma frequency (fp)", " Debye sphere length", and amount of Debye(Nd),  using the spectrum of optical emission technique. There are several energies used, with ranging from 300 to 600 mJ. The Boltzmann Plot is used to calculate the temperature; where as Stark's Line Broadening is used to calculate the electron density. The Indian costus was spectroscopically examined in the air with the laser  at 10 cm away from the target and the optical fiber  at 0.5 cm away. The results were obtained for an electron temperature range of (1.8-2.2) electron volts (ev) and a wavelength range of (300-600) nm. The XRF analysis reveals th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 02 2019
Journal Name
Baghdad Science Journal
Proposing a Scheme for Human Interactive Proof Test using Plasma Effect
...Show More Authors

            Human Interactive Proofs (HIPs) are automatic inverse Turing tests, which are intended to differentiate between people and malicious computer programs. The mission of making good HIP system is a challenging issue, since the resultant HIP must be secure against attacks and in the same time it must be practical for humans. Text-based HIPs is one of the most popular HIPs types. It exploits the capability of humans to recite text images more than Optical Character Recognition (OCR), but the current text-based HIPs are not well-matched with rapid development of computer vision techniques, since they are either vey simply passed or very hard to resolve, thus this motivate that

... Show More
View Publication Preview PDF
Scopus (5)
Scopus Clarivate Crossref
Publication Date
Sat Apr 06 2024
Journal Name
Indian Journal Of Physics
Investigating the effect of alternating voltage frequency on plasma jet parameters
...Show More Authors

View Publication
Scopus
Publication Date
Sat Jan 01 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
The effect of plasma jet-generated gold nanoparticles on liver functions
...Show More Authors

In this study, gold nanoparticles (AuNPs) were synthesized using a plasma jet system at different exposure times. Using ultraviolet, visible spectra, X-ray diffraction, the nanoparticles were characterized (XRD). A Plasmon surface resonance concentrated at 530, 540, and 533 nm for the prepared AuNPs. The pattern of XRD showed that the extreme peaks of the film reflect crystalline existence. The face-centered cubic structure of the gold nanoparticles was prepared for all samples, with an average crystallite size of 25-40 nm. The effect of AuNPs in vivo on liver function levels was measured. For all doses, we notice an increase in the ranks of liver function in the blood during the period of dosing, and it begins to decrease when the dosi

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Plasma Medicine
Effect of Cold Atmospheric Plasma on Osteoporosis by FE-DBD System
...Show More Authors

The work demonstrates the effect of cold atmospheric plasma (CAP) on adult female rats suffering from osteoporosis, the used plasma was generated by a floating electrode-dielectric barrier discharge system with an electrode diameter of 3 cm. The output power was from (12-20) watts. The effect of non-thermal plasma was observed on rats with various exposure times of 20, 30, and 40 sec. It was noted that the blood calcium percentage of animals exposed to cold plasma increased, as well as an increase in the level of vitamin D3 at the same time, it is noted that there is no effect on parathyroid hormone level. For the thyroid gland, it is noticed an increase in the level of T3, and T4 hormones in the blood during the period of induction for

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sat May 25 2024
Journal Name
Optical And Quantum Electronics
Enhancing plasma jet parameters control by external magnetic field strength variation
...Show More Authors

Abstract This research scrutinizes the impact of external magnetic field strength variations on plasma jet parameters to enhance its performance and flexibility. Plasma jets are widely used for their high thermal and kinetic energy in both medical and industrial fields. The study employs optical emission spectroscopy to measure electron temperature, electron density, and plasma frequency in a plasma jet subjected to varying magnetic field strengths (25, 50, 100, 150, and 250 mT). The results indicate that a stronger magnetic field results in higher electron temperature (1.485 to 1.991 eV), electron density (5.405 × 1017 to 7.095 × 1017), and plasma frequency 7.382 × 1012 to 8.253 × 1012 Hz. As well as the research investigates the influ

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
The axial profile of plasma characteristics of cylindrical magnetron sputtering device
...Show More Authors

In the present work, a d.c. magnetron sputtering system was designed and fabricated. The chamber of this system was includes from two copper coaxial cylinders where the inner one used as a cathode (target) while the outer one used as the anode with Solenoid magnetic coil located on the outer cylinder (anode). The axial profile of magnetic field for various coil current (from 2A to 14 A) are shown. The plasma characteristics in the normal glow discharge region are diagnostics by the 2.2mm diameter Langmuir probe with different length along the cathode and located at different radial positions 1cm and 2cm from the cathode surface. The result of this work shows that, the electron energy distributions at different radial positions along the

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
The Effect of Gas Flow on Plasma Parameters Induced by Microwave
...Show More Authors

In this paper, construction microwaves induced plasma jet(MIPJ) system. This system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate by using flow meter, to diagnose microwave plasma optical emission spectroscopy(OES) was used to measure the important plasma parameters such as electron temperature (Te), residence time (Rt), plasma frequency (?pe), collisional skin depth (?), plasma conductivity (?dc), Debye length(?D). Also, the density of the plasma electron is calculated with the use of Stark broadened profiles

View Publication Preview PDF
Scopus (18)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Salivary α-amylase and Flow Rate Levels and Their Correlation with Gingivitis and Severity of Chronic Periodontitis (Part: 1)
...Show More Authors

Background: Periodontal diseases are bacterial infections of the gingiva, bone and attachment fibers that support the teeth and hold them in the jaw. α-amylase is an enzyme, produced mainly by parotid gland and it seems to play a role in maintaining mucosal immunity. Aims of the study: Determine the salivary levels of α-Amylase and flow rate and their correlations with clinical periodontal parameters(Plaque Index , Gingival Index , Bleeding on Probing , Probing Pocket Depth , and Clinical Attachment Level ) and the correlation between α-Amylase with flow rate of study groups that consist of ( patients had gingivitis and patients had chronic periodontitis with different severities(mild ,moderate ,severe) and control group . Ma

... Show More
View Publication Preview PDF
Crossref (2)
Crossref