Background Cardiovascular disease (CVD) is a leading cause of death worldwide. Ischemic heart disease is a major cause of morbidity and mortality. Lack of blood supply to the brain can cause tissue death if any of the cerebral veins, carotid arteries, or vertebral arteries are blocked. An ischemic stroke describes this type of event. One of the byproducts of methionine metabolism, the demethylation of methionine, is homocysteine, an amino acid that contains sulfur. During myocardial ischemia, the plasma level of homocysteine (Hcy) increases and plays a role in many methylation processes. Hyperhomocysteinemia has only recently been recognized as a major contributor to the increased risk of cardiovascular disease (CVD) owing to its effects on atherothrombosis and improvement of oxidative stress-induced endothelial dysfunction, joining the ranks of other known risk factors such as hyperlipidemia, hypertension, diabetes, and advanced age. Objective The purpose of this study was to determine whether there is a relationship between elevated serum total homocysteine (tHcy) levels and an increased risk of coronary artery disease (CAD) in an Iraqi population of patients with ischemic heart disease. Methods This study was conducted at Madinat al-Imamain Al Kadhmain Hospital’s Cardiology Department in Baghdad, Iraq. The study lasted for six months and was designed as an observational case-control study from November 1, 2023, to April 1, 2024. Results Cases and controls had similar characteristics but differed significantly in serum homocysteine concentration. The mean homocysteine level in case group was 40.21±14.47 mmol/L and 9.23±2.41 mmol/L in control group with p value <0.001. Conclusion In young individuals, hyperhomocysteinemia is positively associated with coronary artery, even when other traditional risk factors are not present.
Non-thermal atmospheric pressure plasma has emerged as a
new promising tool in medicine and biology. In this work, A DBD
system was built as a source of atmospheric pressure non-thermal
Plasma suitable for clinical and biological applications. E. coli and
staphylococcus spp bacteria were exposed to the DBD plasma for a
period of time as inactivation (sterilization) process. A series of
experiments were achieved under different operating conditions. The
results showed that the inactivation, of the two kinds of bacteria, was
affected (increasing or decreasing) according to operation conditions
because they affects, as expected, the produced plasma properties
according to those conditions.
Background: This study aimed to determine whether there is a relationship among the bite force with facial dimensions and dental arches in a sample of Iraqi adults with Class I skeletal and dental relations. Materials and methods: Forty dental students (20 males and 20 females) were selected under certain criteria. For those individuals, dental impressions, frontal facial photographs and maximum bite force at molar and incisor regions were taken. The dental arches widths and facial dimensions were measured using the AutoCAD program 2007, while the bite force was determined using special device. Descriptive statistics for the measured variables were performed and gender difference was determined using independent sample t-test, while the rel
... Show MoreTotal no. of patient (100) stool samples were collected, during the period from February to the end of May of 2008, for children under two years old suffering from non-bloody and bloody diarrhea at (Children Welfare Teaching Hospital) in Baghdad. The study evaluates the relationship between etiological agent of diarrhea and sex, age group, type of feeding, presence of blood in stool of the patients. All samples were examined microscopically to identify parasitic agent and serological test for Rotavirus to identify viral infection, also biochemical and serological tested for specimen's culture on different culture media and antibiotic sensitivity test. Results show from 100 cases 64] represents the etiological agent of diarrhea and
... Show MoreBACKGROUND: Clavicle fractures are common injuries in young active individuals, the mid third of the clavicle is most commonly fractured part(80% of clavicle fracture) OBJECTIVE: To compare the outcomes of operative and non operative management of displaced and or comminuted closed fracture of the mid third of clavicle in young adults PATIENTS AND METHODS: This prospective observational study of 24 patients of fracture of the mid third of the clavicle was conducted in Alkindy teaching hospital from July 2015 to January 2017 and divided into two groups; one managed by operative treatment with plate and screws and the other by non operative sling immobilization after taking the consent and the patients were seen at 2, 4, 6 weeks,3, 6, and 9 m
... Show MoreBackground: With the start of the current century, increased the interest in the role of the adipose tissue derived substances that named adipokines in the inflammatory diseases of the human being including the inflammatory periodontal disease, but scientific evidences were not clearly demonstrate the association between these adipokines and periodontal pathologies. Materials and Methods: Forty two subjects male only with normal body mass index were selected for the study with an age ranged (30-39 years). Samples were divided into three groups of 14 subjects in each group based on clinical periodontal parameters; clinically healthy gingiva (group I), gingivitis group (group II) and chronic periodontitis patients group (group III), from whom
... Show MoreThe holmium plasma induced by a 1064-nmQ-switched Nd:YAG laser in air was investigated. This work was done theoretically and experimentally. Cowan code was used to get the emission spectra for different transition of the holmium target. In the experimental work, the evolution of the plasma was studied by acquiring spectral images at different laser pulse energies (600,650,700, 750, and 800 mJ). The repetition rates of (1Hz and 10Hz) in the UV region (200-400 nm). The results indicate that, the emission line intensities increase with increasing of the laser pulse energy and repetition rate. The strongest emission spectra appeared when the laser pulse energy is 800mJ and 10 Hz repetition rate at λ= 345.64nm, with the maximum intensi
... Show MoreIn this research, Argon gas was used to generate atmospheric plasma in the manufacture of platinum nanomaterials, to study the resultant plasma spectrum and to calculate the cellular toxicity of those manufactured nanomaterials. This research is keen on the generation of nonthermal atmospheric pressure plasma using aqueous platinum salts (H2PtCl6 6H2O) with different concentrations and exposure of cold plasma with a different time period used to produce platinum nanoparticles, to ensure typical preparation of nanoparticles. Visible UV and X-rays were performed for this purpose, and the diameter of the system probe was (1[Formula: see text]mm) with the Argon gas flow of
... Show MoreDiamond-like carbon, amorphous hydrogenated films forms of carbon, were pretreated from cyclohexane (C6H12) liquid using plasma jet which operates with alternating voltage 7.5kv and frequency 28kHz. The plasma Separates molecules of cyclohexane and Transform it into carbon nanoparticles. The effect of argon flow rate (0.5, 1 and 1.5 L/min) on the optical and chemical bonding properties of the films were investigated. These films were characterized by UV-Visible spectrophotometer, X-ray diffractometer (XRD) Raman spectroscopy and scanning electron microscopy (SEM). The main absorption appears around 296, 299 and 309nm at the three flow rate of argon gas. The value of the optical energy gap is 3.37, 3.55 and 3.68 eV at a different flow rate o
... Show MoreThe present work intends to study of dc glow discharge were generated between pin (cathode) and a plate (anode) in Ar gas is performed using COMSOL were used to study electric field distribution along the axis of the discharge and also the distribution of electron density and electron temperature at constant pressure (P=.0.0mbar) and inter electrode distance (d=4 cm) at different applied voltage for both pin cathode system and plate anode and comparison with experimental results.