Preferred Language
Articles
/
vebDsZ0BmraWrQ4drVoZ
User Oriented Calibration Method for Stonex X300 Terrestrial Laser Scanner
...Show More Authors

    Terrestrial laser scanners (TLSs) are 3D imaging systems that provide the most powerful 3D representation and practical solutions for various applications. Hence this is due to effective range measurements, 3D point cloud reliability, and rapid acquisition performance. Stonex X300 TOF scanner delivered better certainty in far-range than in close-range measurements due to the high noise level inherent within the data delivered from Time of Flight (TOF) scanning sensors. However, if these errors are manipulated properly using a valid calibration model, more accurate products can be obtained even from very close-range measurements. Therefore, to fill this gap, this research presents a user-oriented target-based calibration routine to compute the calibration parameters of Stonex X300 TLS. The proposed routine investigates range and angular measurements to mitigate mechanical misalignment error sources of this device. Distance and angular index errors were computed, and environmental error sources were considered for optimal modeling estimation. The approach is based to reference measurements in a close-range environment within a 10-meter distance to user-defined ground truth targets. Experiment results show that the errors in the distance are generally increased following the increase in range distance between the laser device and the targets. However, error variations between laser and reference measurements nearly constant relational to the range value. The index error of the Stonex X300 was computed based on mean measurements and found to be equal to 4.6717 mm. On the other hand, the horizontal angular measurements delivered from the TLS device were found to be more consistent with the reference measurements than with thee vertical angular measurements. However, the vertical angular measurements show more significant variations in particular measures compared to horizontal angular measurements. Following this, the angular error index was computed and found to be equal to 0.07 seconds and 0.13 seconds in horizontal and vertical angular measurements, respectively.

Scopus Crossref
View Publication
Publication Date
Mon Jun 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Breast Tumor Diagnosis Using Diode Laser in Near Infrared Region
...Show More Authors

In the last years, new non-invasively laser methods were used to detect breast tumors for pre- and postmenopausal females. The methods based on using laser radiation are safer than the other daily used methods for breast tumor detection like X-ray mammography, CT-scanner, and nuclear medicine.  

      One of these new methods is called FDPM (Frequency Domain Photon Migration). It is based on the modulation of laser beam by variable frequency sinusoidal waves. The modulated laser radiations illuminate the breast tissue and received from opposite side.

      In this paper the amplitude and the phase shift of the received signal were calculated according to the orig

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 11 2003
Journal Name
Iraqi Journal Of Laser
Microdrop Size Measurement in a Mixing Unit Using Laser Technique
...Show More Authors

One of the troublesome duties in chemical industrial units is determining the instantaneous drop size distribution, which is created between two immiscible liquids within such units. In this work a complete system for measuring instantaneous droplet size is constructed. It consists of laser detection system (1mW He-Ne laser), drop generation system (turbine mixer unit), and microphotography system. Two immiscible liquids, water and kerosene were mixed together with different low volume fractions (0.0025, 0.02) of kerosene (as a dispersed phase) in water (as a continuous phase). The experiments were carried out at different rotational speed (1180- 2090 r.p.m) of the turbine mixer. The Sauter mean diameter of the drops was determined by la

... Show More
View Publication Preview PDF
Publication Date
Thu May 01 2014
Journal Name
Engineering And Technology Journal
Relativistic Self-Focusing of Intense Laser Beam in Magnetized Plasma
...Show More Authors

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jun 11 2003
Journal Name
Iraqi Journal Of Laser
Q- Switched Nd:YAG Laser Annealing of Phosphorus Diffused Silicon Photodiodes
...Show More Authors

Improvement of optoelectrical characteristics of phosphorus diffused silicon photodiodes by Q-switched Nd:YAG laser pulses was investigated. Laser pulses have dissolved the precipitation of phosphorus resulted during thermal diffusion process. The experimental data show that responsivity higher than (0.32 A/W) at 850 nm can be achieved after laser annealing with (1.5 MW/cm2) for 6 shots.

View Publication Preview PDF
Publication Date
Fri Aug 14 2015
Journal Name
Journal Of Optoelectronics And Photonics (jop)
Preparation and Characterization of AL2O3 Nanostructures by Pulsed – Laser Deposition
...Show More Authors

Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser
...Show More Authors

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 16 2008
Journal Name
Iraqi Journal Of Laser
Treatment of Oral Pyogenic Granuloma by 810 nm Diode Laser
...Show More Authors

Pyogenic granuloma is one of the inflammatory hyperplasia seen in the oral cavity. The
present study included 10 patients with pyogenic granuloma, involving 4 males and 6 females with 1:1.5
male to female ratio. Patient ages ranged from 5 to 85 years (mean, 30 years) and half of the lesions had
pedunculated base, with surface ulceration in 10% of cases. Treatment consisted of resection, using 810
nm diode lasers. Eight patients were anesthetized during the surgical operation by local infiltration of
anesthesia. Only three patients reported mild post-operative pain within the first 24 hours of the healing
period. During the surgical operation there was no significant bleeding so clear surgical field. There was
no blee

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 15 2020
Journal Name
Iraqi Journal Of Laser
Hole Drilling of High Density Polyethylene using Nd:YAG Pulsed Laser
...Show More Authors

This paper presents the theoretical and experimental results of drilling high density
polyethylene sheet with thickness of 1 mm using millisecond Nd:YAG pulsed laser. Effects of laser
parameters including laser energy, pulse duration and peak power were investigated. To describe and
understand the mechanism of the drilling process Comsol multiphysics package version 4.3b was used to
simulate the process. Both of the computational and experimental results indicated that the drilling
process has been carried out successfully and there are two phases introduced in the drilling process,
vaporization and melting. Each portion of these phases depend on the laser parameters used in the
drilling process

View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Bartholin Gland Cyst Treatment using Carbon Dioxide Laser (10600 nm)
...Show More Authors

The Bartholin gland cyst is a condition that occurs in approximately 2% of women, most of whom are of reproductive age. Although benign pathology, it is associated with significant patient discomfort. This disorder is caused by the obstruction and consequent dilation of the cyst duct. Definitive treatment involves the surgical removal of the entire cyst. Other alternative treatments include Marsupialization, Word catheter, and the use of CO2 laser. CO2 laser can be used either to vaporize or to excise the Bartholin gland cyst. The Objectives: The purpose of the study was to evaluate the efficacy and safety of (10600nm) CO2 laser in the treatment of Bartholin gland cyst. Patients, Materials & Methods: This study was done in laser medi

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Investigation of Thermal Stress Distribution in Laser Spot Welding Process
...Show More Authors

The objective of this paper was to study the laser spot welding process of low carbon steel sheet. The investigations were based on analytical and finite element analyses. The analytical analysis was focused on a consistent set of equations representing interaction of the laser beam with materials. The numerical analysis based on 3-D finite element analysis of heat flow during laser spot welding taken into account the temperature dependence of the physical properties and latent heat of transformations using ANSYS code V.10.0 to simulate the laser welding process. The effect of laser operating parameters on the results of the temperature profile were studied in addition to the effect on thermal stresses  and dimensions of the laser w

... Show More
View Publication Preview PDF