Preferred Language
Articles
/
vebDsZ0BmraWrQ4drVoZ
User Oriented Calibration Method for Stonex X300 Terrestrial Laser Scanner
...Show More Authors

    Terrestrial laser scanners (TLSs) are 3D imaging systems that provide the most powerful 3D representation and practical solutions for various applications. Hence this is due to effective range measurements, 3D point cloud reliability, and rapid acquisition performance. Stonex X300 TOF scanner delivered better certainty in far-range than in close-range measurements due to the high noise level inherent within the data delivered from Time of Flight (TOF) scanning sensors. However, if these errors are manipulated properly using a valid calibration model, more accurate products can be obtained even from very close-range measurements. Therefore, to fill this gap, this research presents a user-oriented target-based calibration routine to compute the calibration parameters of Stonex X300 TLS. The proposed routine investigates range and angular measurements to mitigate mechanical misalignment error sources of this device. Distance and angular index errors were computed, and environmental error sources were considered for optimal modeling estimation. The approach is based to reference measurements in a close-range environment within a 10-meter distance to user-defined ground truth targets. Experiment results show that the errors in the distance are generally increased following the increase in range distance between the laser device and the targets. However, error variations between laser and reference measurements nearly constant relational to the range value. The index error of the Stonex X300 was computed based on mean measurements and found to be equal to 4.6717 mm. On the other hand, the horizontal angular measurements delivered from the TLS device were found to be more consistent with the reference measurements than with thee vertical angular measurements. However, the vertical angular measurements show more significant variations in particular measures compared to horizontal angular measurements. Following this, the angular error index was computed and found to be equal to 0.07 seconds and 0.13 seconds in horizontal and vertical angular measurements, respectively.

Scopus Crossref
View Publication
Publication Date
Wed Jul 22 2020
Journal Name
International Journal Of Research In Pharmaceutical Sciences
Cloud point extraction method for the sensitive determination of metoclopramide hydrochloride in pharmaceutical dosage forms
...Show More Authors

In this work, a simple and very sensitive cloud point extraction (CPE) process was developed for the determination of trace amount of metoclopramide hydrochloride (MTH) in pharmaceutical dosage forms. The method is based on the extraction of the azo-dye results from the coupling reaction of diazotized MTH with p-coumaric acid (p-CA) using nonionic surfactant (Triton X114). The extracted azo-dye in the surfactant rich phase was dissolved in ethanol and detected spectrophotometrically at λmax 480 nm. The reaction was studied using both batch and CPE methods (with and without extraction) and a simple comparison between the two methods was performed. The conditions that may be affected by the extraction process and the sensitivity of m

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Synthesized pure cobalt oxide nanostructure and doped with yttrium by hydrothermal method for photodetector applications
...Show More Authors

In this study, pure Co3O4 nano structure and doping with 4 %, and
6 % of Yttrium is successfully synthesized by hydrothermal method.
The XRD examination, optical, electrical and photo sensing
properties have been studied for pure and doped Co3O4 thin films.
The X-ray diffraction (XRD) analysis shows that all films are
polycrystalline in nature, having cubic structure.
The optical properties indication that the optical energy gap follows
allowed direct electronic transition calculated using Tauc equation
and it increases for doped Co3O4. The photo sensing properties of
thin films are studied as a function of time at different wavelengths to
find the sensitivity for these lights.
High photo sensitivity dope

... Show More
View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Sat Feb 25 2017
Journal Name
International Journal On Advanced Science, Engineering And Information Technology
A Novel DNA Sequence Approach for Network Intrusion Detection System Based on Cryptography Encoding Method
...Show More Authors

A novel method for Network Intrusion Detection System (NIDS) has been proposed, based on the concept of how DNA sequence detects disease as both domains have similar conceptual method of detection. Three important steps have been proposed to apply DNA sequence for NIDS: convert the network traffic data into a form of DNA sequence using Cryptography encoding method; discover patterns of Short Tandem Repeats (STR) sequence for each network traffic attack using Teiresias algorithm; and conduct classification process depends upon STR sequence based on Horspool algorithm. 10% KDD Cup 1999 data set is used for training phase. Correct KDD Cup 1999 data set is used for testing phase to evaluate the proposed method. The current experiment results sh

... Show More
View Publication
Scopus (10)
Crossref (6)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Baghdad Science Journal
Synthesis AgO Nanoparticles by Nd:Yag Laser with Different Pulse Energies
...Show More Authors

     One technique used to prepare nanoparticles material is Pulsed Laser Ablation in Liquid (PLAL), Silver Oxide nanoparticles (AgO) were prepared by using  this technique, where silver target was submerged in ultra-pure water (UPW)  at room temperature after that Nd:Yag laser which characteristics by 1064 nm wavelength, Q-switched, and 6ns pulse duration was used to irradiated silver target. This preparation method was used to study the effects of laser irradiation on Nanoparticles synthesized by used varying laser pulse energy 1000 mJ, 500 mJ, and 100 mJ, with 500 pulses each time on the particle size. Nanoparticles are characterized using XRD, SEM, AFM, and UV-Visible spectroscopy. All the structural peaks determined by the XRD

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Materials Today Communications
Fe2O3-SiO2 nanocomposite film-induced high nonlinear effect for multiwavelength mode-locked generation in ytterbium-doped fiber laser
...Show More Authors

In this work, the possibility of a multiwavelength mode-locked fiber laser generation based on Four-Wave Mixing (FWM) induced by Fe2O3-SiO2 nanocomposite material is investigated for the first time. A multiwavelength mode-locked pulses fiber laser are generated from Ytterbium–doped fiber laser (YDFL) due to the combined action of high nonlinear absorption and high refractive coefficients of Fe2O3-SiO2 nanocomposite incorporated inside YDFL ring cavity. Up to more than 20 lasing lines in the 1040–1070 nm band with an equally lines separation of ~0.6 nm have been observed by just simple variation of passive modulation of the state of the polarization and the pump power altogether. Moreover, a passively mode-locked operation of YDFL laser

... Show More
View Publication
Scopus (9)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Fri Jun 30 2023
Journal Name
International Journal Of Intelligent Engineering And Systems
DeepFake Detection Improvement for Images Based on a Proposed Method for Local Binary Pattern of the Multiple-Channel Color Space
...Show More Authors

DeepFake is a concern for celebrities and everyone because it is simple to create. DeepFake images, especially high-quality ones, are difficult to detect using people, local descriptors, and current approaches. On the other hand, video manipulation detection is more accessible than an image, which many state-of-the-art systems offer. Moreover, the detection of video manipulation depends entirely on its detection through images. Many worked on DeepFake detection in images, but they had complex mathematical calculations in preprocessing steps, and many limitations, including that the face must be in front, the eyes have to be open, and the mouth should be open with the appearance of teeth, etc. Also, the accuracy of their counterfeit detectio

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (13)
Scopus Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Laser
Laser Microdrilling and Nanodrilling of 8009 Aluminium Alloy using Nanoparticles
...Show More Authors

 The microdrilling and nanodrilling holes are produced by a Q-switched Nd :YAG laser (1064 nm) interaction with 8009 Al alloy using nanoparticles. Two kinds of nanoparticles were used with this alloy. These nanoparticles are tungsten carbide (WC) and silica carbide (SiC). In this work, the microholes and nanoholes have been investigated with different laser pulse energies (600, 700 and 800)mJ, different repetition rates (5Hz and 10Hz) and different concentration of nanoparticles (90%, 50% and 5% ). The results indicate that  the microholes and nanoholes have been achieved when the laser pulse energy is 600 mJ, laser repetition rate is 5Hz, and the concentration of the  nanoparticles (for the two types of n

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Laser Finger Print Sensor with Holographic Grating
...Show More Authors

Design and Construction system for recording Finger print by laser, and separted the signal to noise by holographic element, was done. For safety, total reflection lighting ensures hat aser earns an not enter An operators eyes. Holographic diffraction grating was used instead of computer program to contrast images.

View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Acne Scar Management by Fractional CO2 Laser
...Show More Authors

Acne scars are one of the most common problems following acne vulgaris. Despite the extensive list of available treatment modalities, their effectiveness depends upon the nature of the scar. Ablative lasers had been used to treat acne scars; one of them is the fractional CO2 laser. The aim of this study is to evaluate the outcome of fractional CO2 laser in the treatment of acne scars. Methods: Since January 2010 to June 2013, using 10600 nm fractional CO2 laser beams, the acne scar of 400 patients, 188 males and 212 females, mean age of 34 years, have been treated and classified according to severity into four grades following Goodman and Baron classification. Each patient underwent 3-5 sessions once monthly. The mean laser exposure time

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 01 2020
Journal Name
Iraqi Journal Of Laser
Treatment of facial acne scar using Fractional Er: YAG laser
...Show More Authors

Background: Acne is a common disorder experienced by adolescents and persists into adulthood in approximately 12%–14% of cases with psychological and social implications of high gravity. Fractional resurfacing employs a unique mechanism of action that repairs a fraction of skin at a time. The untreated healthy skin remains intact and actually aids the repair process, promoting rapid healing with only a day or two of downtime. Aims: This study, was designed to evaluate the safety and effectiveness of fractional photothermolysis (fractionated Er: YAG laser 2940nm) in treating atrophic acne scars. Methods: 7 females and 3 males with moderate to severe atrophic acne scarring were enrolled in this study that attained private clinic for Derm

... Show More
View Publication Preview PDF