In this work, the surface of the telescope’s mirror is cleaned using an atmospheric-pressure radio frequency plasma jet (APRFPJ), which is generated by Argon gas between two coaxial metal electrodes. The RF power supply is set to 2 MHz frequencies with three different power levels: 20, 50, and 80 W. Carbon, that has adhered to the surface, can be effectively removed using the plasma cleaning technique, which also modifies any residual bonds. The cleaned surface was clearly distinguished using an optical emission spectroscopy (OES) technique and a water contact angle (WCA) analyzer for the activation property on their surfaces. The sample showed a super hydrophilic surface at an angle of 1° after 2.5 minutes of plasma treatment, as determined by the WCA technique, and an analysis of its optical properties showed that its reflectance had increased from 75% before cleaning to 98% after cleaning. Using the OES technique, the RF plasma jet's spectrum can be observed to contain the ArI, ArII, and NI lines.
In this research, beam expander, BEX, is explained and designed for illuminating the
remote flying target. The BEX is optically designed to be suited for Nd:YAG laser of given
specifications. The BEX is modified to be zoom one to meet the conditions of preventing the
receiving unit; i.e the photodetector, from getting saturated at near and far laser tracking.
Decollimation could be achieved by automatic motor, which controls zoom lens of the BEX
according to the required expansion ratio of beam expander
Atmospheric transmission is disturbed by scintillation, where scintillation caused more beam divergence. In this work target image spot radius was calculated in presence of atmospheric scintillation. The calculation depend on few relevant equation based on atmospheric parameter (for Middle East), tracking range, expansion ratio of applied beam expander's, receiving unit lens F-number, and the laser wavelength besides photodetector parameter. At maximum target range Rmax =20 km, target image radius is at its maximum Rs=0.4 mm. As the range decreases spot radius decreases too, until the range reaches limit (4 km) at which target image spot radius at its minimum value (0.22 mm). Then as the range decreases, spot radius increases due to geom
... Show MoreThe physical substance at high energy level with specific circumstances; tend to behave harsh and complicated, meanwhile, sustaining equilibrium or non-equilibrium thermodynamic of the system. Measurement of the temperature by ordinary techniques in these cases is not applicable at all. Likewise, there is a need to apply mathematical models in numerous critical applications to measure the temperature accurately at an atomic level of the matter. Those mathematical models follow statistical rules with different distribution approaches of quantities energy of the system. However, these approaches have functional effects at microscopic and macroscopic levels of that system. Therefore, this research study represents an innovative of a wi
... Show MoreThe present study was conducted with a view to determine whether focal laser therapy result in visual recovery and regression of macular edema in patients with non proliferative diabetic retinopathy and maculopathy ,and whether combined focal and scatter laser therapy in patients with proliferative diabetic retinopathy and maculopathy results in visual recovery ,regression of macular edema and regression of the risk factors. In the present work, a frequency doubled Nd: YAG laser was used for the treatment of diabetic retinopathy. The study evaluates 41 eyes of 33 diabetic patients both with Insulin Dependent Diabetes Mellitus IDDM, (n=16) and Non Insulin Dependent Diabetes Mellitus NIDDM, (n=17) with diabetic retinopathy divided into two
... Show MoreOne of the most opportunistic mycosis globally is the Candida ssp., which is considered as the most agent that cause nosocomial urinary tract infections (UTIs), oral candidiasis and genitourinary candidiasis. This study included 100 samples of Iraqi subjects suffering from urinary tract infections. Identification of Candida have been done by different methods such as; characteristic of colony on culture, gram stain, and microscopically. This study aimed to isolation and identification of Candida spp from urine sample of UTI patients and find the relevance of ages and blood group of patients with the infections rate, also determine the effect of age on ESR and CRP levels in the patients. The results showed the higher frequency of
... Show MoreBackground: Neonatal macrosomia is defined as a birth weight of more than 4000 g. Significant maternal and neonatal complications can result from the birth of macrosomic infants like hypoglycemia and birth injuries.Objectives: To determine the frequency of hypoglycemia in neonates with macrosomia in Amarah, IraqMethods: The study involved 146 macrosomic newborn neonates delivered in 2 maternity hospitals in Amarah, Iraq during a period from June 2011 to June 2014.Results: Hypoglycemia was observed in 16% of neonates affected by macrosomia. Maternal diabetes was the most common cause of fetal macrosomia (28%).Our results were compared with those from other parts of the world.Conclusion Macrosomia is associated with increase rate ofneonata
... Show MoreKE Sharquie, AA Noaimi, SY Mohsin, 2011 - Cited by 4
Fifty one patients with serologically confirmed brucellosis and 70 healthy controls were phenotyped for HLA-A, -B, -DR and -DQ antigens by using standard microlympho-cytotoxicity method, and lymphocytes defined by their CD markers (CD3, CD4, CD8 and CD19). The results revealed a significant (Pc = 0.001) increased frequency of HLA-DR8 (41.18 vs. 10.0%) in the patients . A significant increased percentage of CD8+ lymphocytes was also increased in the patients (25.15 vs. 22.0%; P = 0.006), while CD3+ lymphocytes were significantly decreased (75.1 vs. 79.4%; P = 0.02).