The modern industrial projects and complexes that adopt ecological systems, and renewable, clean and environmentally friendly energy, not only contribute to the development of an environmentally friendly production method but can achieve long-term economic and industrial development by preserving environmental resources. The ecological industrial systems and modern industrial technologies are the ideal solutions to rationalize excessive use and preserve the elements of the environment and natural resources, the most important of which is the existence of several methods and programs for the development of industrial sites, and there is important to adopt mechanisms and programs to solve the problems of traditional industries to reach industrial techniques characterized by rationalization, reduction in the depletion of natural resources, the most important of which is the triple system (reduction, recycling, and reuse of industrial waste) and other eco-systems. By applying the indicators to the study area in the new industrial city in Ramady, it was found that there is a weakness in the application of the indicators and did not achieve the required level. It becomes clear to us the need to take into account the activation of these indicators to reach the achievement within the industrial city.
This research aims to studying and analyzing the theoretical
framework of the environmental auditing in industrial environment to its a broad and danger environmental effects . It aims to contribute in setting and testing a proposed procedure framework for environmental auditing in that vital activity .The practical aspect focused on testing a proposed framework within practice it in a one Iraqi industrial company that has a huge effect on environmental activity, represented by Iraqi state company
Four samples were collected from the wastewater of State Battery Manufacturing Company (SBMC); Babylon 2 factory in AL-Waziriya district, as triplicates. Physical and chemical measurements were carried out such as temperature, pH, Lead concentrations and their ranges were: (19.5-34.5) °C, (6.1-6.4) and (4.5-6.5) mg/L, respectively. Six dominant Bacillus spp. isolates were isolated from these samples; namely, Bacillus subtilis N1, Bacillus subtilis N2, Bacillus subtilis N3, Bacillus cereus N4, Bacillus cereus N5 , Bacillus cereus N6. These isolates were capable of removing Lead from aqueous solutions in a capacity reached 27.6 ± 1.4, 10.1 ± 1.7, 74.5 ± 0.7, 8.93 ± 2.8, 8.1 ± 3.5, 1.6± 0.7 mg/L, respectively. Whereas cell walls,
... Show MoreElectro coagulation treatment was used for zinc removal from electroplating wastewater of the State Company for Electrical Industries . This wastewater, here consists zinc ions with maximum concentration in solution of 90 ppm .
The parameters that influenced the wastewater treatment are: current density in the range 1-1.4 mA/cm2, pH in the range 5-10, temperature in the range 25-45°C and time in the range 10-180 minute.
The research is a laboratory experimental type using batch system for electrical process with direct current. The cell comprised of aluminum electrode as anode and stainless steel electrode as cathode. Thirty experiments and one hundred fifty sample lab tests were carried out in this research
... Show MoreThe analysis and efficiency of phenol extraction from the industrial water using different solvents, were investigated. To our knowledge, the experimental information available in the literature for liquid-liquid equilibria of ternary mixtures containing the pair phenol-water is limited. Therefore the purpose of the present investigation is to generate the data for the water-phenol with different solvents to aid the correlation of liquid-liquid equilibria, including phase diagrams, distribution coefficients of phenol, tie-lines data and selectivity of the solvents for the aqueous phenol system.
The ternary equilibrium diagrams and tie-lines
... Show MoreCadmium is one of the heavy metal found in the wastewater of many industries. The electrocoagulation offers many advantages for the removal of cadmium over other methods. So the removal of cadmium from wastewater by using electrocoagulation was studied to investigate the effect of operating parameters on the removal efficiency. The studied parameters were the initial pH, initial concentration, and applied voltage. The study experiments were conducted in a batch reactor with with two pairs of aluminum electrodes with dimension and 2mm in thick with 1.5 cm space between them. The optimum removal was obtained at pH =7, initial concentration = 50 mg/L, and applied voltage = 20 V and it was 90%.
The aim of this study was to use low cost adsorbents, which consist of corn cobs as plant wastes adsorbents in treatment of Industrial waste water by fixed bed column technique and study the effect of two variables (pH value and contact time). The sample of plant waste (Corn cobs) was tested to determine its activity which gives the best performance in heavy metals removal and other pollutants (TSS, TDS and COD). Adsorption tests showed the corn cobs adsorbents had significant heavy metal removal efficiency. The best removal efficiency 95.05% of Cr was occurred at pH 5.4 and 4.18hr. Higher removal efficiency 99.90% of Ni was occurred at pH 6.5 and 2.38hr. While, lower removal efficiency 91.35% for Zn obtained at pH 6.5 and 0.15hr. Remova
... Show MoreThe aim of this study was to use low cost adsorbents, which consists of plant wastes in treatment of Industrial waste water by fixed bed column technique and study the effect of to two variables (pH value and contact time) on adsorption process. The sample of plant waste (Rice husk) was tested to determine its activity which gives the best performance in heavy metals removal and other pollutants (TSS, TDS and COD). Adsorption tests showed all tested plant adsorbents had significant heavy metal removal efficiency. The best removal efficiency 96.56% of Cr was occurred at pH 6.5 and 5hrs. Higher removal efficiency 99.02% of Ni was occurred at pH 6.5 and 0.15hr. While, lower removal efficiency 94% for Zn obtained at pH 5 and 2.83hrs. Removal
... Show MoreThe 2D imaging survey was carried out using Wenner-Schlumberger array through (11) 2D survey lines distributed within and out of Abu-Jir fault zone, Southwest of Karbala City, central Iraq. The aim is to delineate subsurface fractures density. The total length of each 2D survey line is (600m.) with the unit electrode spacing (a) equals to (10m.).The results showed two types of fractures zones. The first type is formed by dissolution process of carbonate rocks, while the second fractures zone is formed from tectonic movements, and it includes two types of fractures system, oblique and vertical fractures.
This study includes comparison between subsurface fracture density within and out of Abu- Jir fault zone. This comparison showed that
The research is to identify the legend of the seven eyes amulet of Babylonian origin and the representations it carried of the link between the Babylonian past and the Islamic present presented in the design works of the promoted products, preserving its impact in the souls as a way to avoid the act of envy, and from this was the research problem that I want to get answers to, which That is (How was the legend of the seven-eyes amulet represented in the design of industrial products?), making its goal to identify how that legend was represented within the design work of marketed industrial products, and in order to reach the answer, the research presented many concepts starting with the legend in its various forms in industrial products.
... Show MoreThis study which was carried out from Jan /2010 to Jan/2011,evolution of the efficiency
of treatment unit of al-Ameen factory , a subsidiary of Vegetable Oils General Company in
al- Za
,
faraniya /Sa
,
idea district /South of Baghdad ,via examing the waters coming out of
treatment unit and the role of this unit in improving waters quality , especially in physical and
chemical characteristics to be main factors in studying water's quality, such as temperature
C°,pH,Ec,DO,BOD5,NO3,TDS,PO4
-3
.
The results showed that the characteristics of treated treated water excepte of the Ec
factor were within the acceptable limits,in spite of the high concentration entering the unit .
This confirms t