The discus throwing event is one of the complex events in athletics, and it is characterized by a performance method that depends on the principle of mechanical moments and requires high explosive capabilities of the thrower in addition to some physical specifications,which depends effectively and effectively on the biomechanical aspects in generating large moments during rotation. The importance of the research is highlighted by the interest in athletics, especially the effectiveness of the discus throw and the continuation of its development process, the importance of kinetic analysis in revealing the most important weaknesses and strengths of shooters, and the importance of explosive power And the moments generated in the rotation of the torso and the throwing arm during the moment of throwing. The research problem centered on showing the numerical values of the moments generated during rotation and their relationship to achievement, focusing on the values of the explosive capabilities of the legs, arms and the body as a whole and their relationship to the achieved achievement. As well as neglecting the science of kinetic analysis and identifying weaknesses with high accuracy, in addition to the lack of interest by the trainers in the characteristics of the values of mechanical moments that affect the flow of the shooter in order to set their training programs according to the priority of those characteristics in achieving their goals by achieving the best completion distance. The aim of the research is to identify the most important moments affecting the torso and the throwing arm, from the stage of applying force to the stage of the final throw, and to the explosive capabilities and their relationship to achievement for advanced discus throwers. The researcher used the descriptive approach and correlations in her current study to suit the nature of the problem of the study. The research community consisted of advanced Iraqi discus throwers, numbering (6) shooters, who took the comprehensive enumeration method. The test was conducted on the research sample in the stadium of the College of Physical Education and Sports Sciences / University of Kufa in preparation for the Iraqi Clubs Championship, the second round. Each shooter was given six attempts as in the official races, and the best attempt was taken as an achievement for the analysis, and an analysis camera (CASIO FH13.5) was used at a speed of 120 frames. In the second, the analysis was done with the analysis program (Kenova)
In this study the Entrance Surface Dose (ESD) received by pediatrics patients undergoing chest, abdomen and skull X-ray examinations was estimated. The study was conducted in two hospitals in Najaf city where three radiographic systems were considered. The study participants were classified into four age groups 0-1 , 1-5 , 5-10 and 10-15 years. Calculations were performed using exposure factors, kVp, mAs and focal-skin distance, together with patient data age. The ESD was calculated for the involved patients who underwent an Antero-posterior (AP) chest, abdomen and skull X-ray examination. The resulted data were analyzed and compared with international dose references. For all studied radiographic examinations and all X-ray mac
... Show MoreThis paper aims to study the effect of circular Y-shaped fin arrangement to improve the low thermal response rates of a double-tube heat exchanger containing Paraffin phase change material (PCM). ANSYS software is employed to perform the computational fluid dynamic (CFD) simulations of the heat exchanger, including fluid flow, heat transfer, and the phase change process. The optimum state of the fin configuration is derived through sensitivity analysis by evaluating the geometrical parameters of the Y-shaped fin. For the same height of the fins (10 mm), the solidification time is reduced by almost 22%, and the discharging rate is enhanced by almost 26% using Y-shaped fins compared with the straight fins. The results demonstrate that the sol
... Show MoreThis paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi
... Show MoreObjective: To assess the impact of a social support for pregnant women upon their pregnancy outcome Methodology: A descriptive purposive study was used to assess the impact of a social support on their pregnancy outcomes. The study was conducted from (22 \ September \ 2020 to 15 \ February \ 2021). A non-probability sample (purposive sample) was selected from 100 women. Data were collected through an interview with the mother in the counseling clinic, during the third trimester of pregnancy, as well as after childbirth in the labor wards to assess the outcome of pregnancy. Data were analyzed through descriptive statistics (frequency and percentages). Results: The most important thing observed in this study was the positive pregnancy outcome
... Show MoreBackground: Hypertension is probably the most important public health problem around the world. People with periodontal disease may be at greater risk of hypertension. The inflammatory effects of periodontal disease help to promote endothelial dysfunction in arteries which may lead to changes in blood pressure. Salivary MMP-8 has been associated with both periodontal disease and prevalent hypertension. Aim of study: This study was conducted to measure salivary matrix metalloproteinase - 8, in relation to periodontal health condition among a group of patients with hypertension in comparison with control group. Materials and methods: Ninety subjects, aged 45-50 years old were included in this study, seeking treatment for chest pain in Ibn-A
... Show MoreStick- slip is the continuous stopping& release of the Bit/BHA due to the irregular down-hole rotation prompted by the existing relationship between the friction torque and the torque applied from the surface to free the bit.
Friction coefficient between BHA and wellbore is the main player of stick slip amount, which can be mitigated by support a good lubricators as additives in drilling mud.
Mathematical (or empirical) solves should be done through adjusting all parameters which supposed to reduce stick- slip as low as possible using different models, one of the main parameters is drilling mud. As per Nanoparticles drilling fluid is a new technology that offers high performance
... Show MoreAbstract
The study of oxygen mass transfer was conducted in a laboratory scale 5 liter stirred bioreactor equipped with one Rushton turbine impeller. The effects of superficial gas velocity, impeller speed, power input and liquid viscosity on the oxygen mass transfer were considered. Air/ water and air/CMC systems were used as a liquid media for this study. The concentration of CMC was ranging from 0.5 to 3 w/v. The experimental results show that volumetric oxygen mass transfer coefficient increases with the increase in the superficial gas velocity and impeller speed and decreases with increasing liquid viscosity. The experimental results of kla were correlated with a mathematical correlation des
... Show MoreIn this paper, a miniaturized 2 × 2 electro-optic plasmonic Mach– Zehnder switch (MZS) based on metal–polymer–silicon hybrid waveguide is presented. Adiabatic tapers are designed to couple the light between the plasmonic phase shifter, implemented in each of the MZS arms, and the 3-dB input/output directional couplers. For 6 µm-long hybrid plasmonic waveguide supported by JRD1 polymer (r33= 390 pm/V), a π-phase shift voltage of 2 V is obtained. The switch is designed for 1550 nm operation wavelength using COMSOL software and characterizes by 2.3 dB insertion loss, 9.9 fJ/bit power consumption, and 640 GHz operation bandwidth
Detection of virulence gene agglutinin-like sequence (ALS) 1 by using molecular technology from clinical samples (