The research aims to shed light on the internet and how to employ them and to take advantage of applications in scientific research among faculty members, from a survey the opinions of professors at the University of Alanbar and Almustansiriah, to see the reality of use of the Internet and ways to invest in the service of scientific research.
The follow descriptive analysis approach , which is appropriate to the nature of this study concerned with exploring the views on the uses of the Internet. The study reached the field the following results:
1- There are(60) % of respondents use the Internet on an ongoing basis to see new information and keep pace with scientific developments in the field of specialty and the average use of the
Shell-and-double concentric tube heat exchanger is one of the new designs that enhance the heat transfer process. Entransy dissipation is a recent development that incorporates thermodynamics in the design and optimization of heat exchangers. In this paper the concept of entransy dissipation is related to the shell-and-double concentric tube heat exchanger for the first time, where the experiments were conducted using hot oil with temperature of 80, 100 and 120°C, flow rate of cold water was 0.667, 1, and 1.334 kg/m3 respectively and the temperature of inlet cold water was 20°C. The entransy dissipation rate due to heat transfer and to fluid friction or pressure drop was studied.
Alopecia areata is considered as a major health problem, its importance is attributed to its
recent increased incidence in our population. Till now, there is no exact cause for alopecia areata
although researchers thought it's an autoimmune disease.
This clinical study was designed to evaluate the role of trace elements (zinc and copper) in patients
with alopecia areata. Twenty patients were diagnosed as having alopecia areata with an age range
(10-40 years) were involved in this study. Normal subjects of the same age group were also
evaluated as control. The level of serum Zn and Cu were measured by flame atomic absorption
spectrophotometry in both control and patient group. And the ratio of Zn/Cu was also estimated
Previous studies on the synthesis and characterization of metal chelates with uracil by elemental analysis, conductivity, IR, UV-Vis, NMR spectroscopy, and thermal analysis were covered in this review article. Reviewing these studies, we found that uracil can be coordinated through the electron pair on the N1, N3, O2, or O4 atoms. If the uracil was a mono-dentate ligand, it will be coordinated by one of the following atoms: N1, N3 or O2. But if the uracil was bi-dentate ligand, it will be coordinated by atoms N1 and O2, N3 and O2 or N3 and O4. However, when uracil forms complexes in the form of polymers, coordination occurs through the following atoms: N1 and N3 or N1 and O4.
In this paper some chalcones (C1-C8) are prepared based on the reaction of one mole of substituted acetophenone with one mole of substituted benzaldehydes in the presence of (40%) sodium hydroxide as a base. Pyrazolines (P1–P8) are prepared from the reaction of chalcones (C1-C8) with hydrazine hydrate. Isoxazoline (I1-I8) is prepared from the reaction of chalcones (C1-C8) with hydroxyl amine hydrochloride in the presence of (10%) sodium hydroxide as a base. These compounds are characterized by using various physical and spectral methods. The compounds are screened for their in vitro antibacterial activity using gram-positive bacteria and gram-negative bacteria. Several derivatives of pyrazolines and isoxazolines are produced well to moder
... Show MoreReverse Phase High Performance Liquid Chromatography (RP-HPLC) was coupled with ultraviolet absorption sepectoscopy (UV) for separation and identification of Naphthalene, Acenaphthylene, Pyrene, Benz{a} anthracene and 1,3,2,4-Dibenzanthracene. RP-HPLC was performed on an ODS-C18 column (150×4.6 mm I.D) using acetonitrile–buffer phosphate as mobile phase. UV absorption spectra of the elutes was detected in 254 nm, and studying the chromatographic variables include organic modifier ratio, PH, column temperature and concentration of buffer to maximize resolution and minimize separation time. the results showed that using mobile phase( 80:20) v/v acetonitrile:0.01M phosphate buffer solution at PH 6 with flow rate 1ml/min and column te
... Show More