Amis: NAFLD is considered to be the most common cause of liver conditions worldwide. Also, it is a primary reason that leads to coronary artery diseases, limiting blood flow to the heart. Therefore, This study aimed to evaluate the serum level of Nesfatin-1 and its ability to indicate the prognosis of CAD in patients with NAFLD. Material & Methods: one-hundred eighty Individuals were enrolled in the study, including In both genders, blood was collected from each Individual and sent to the laboratory for biochemical tests. Findings: Data from the current study showed a significant increase in Nesfatin-1 in the CAD group and a significant decrease in Nesfatin-1 in the NAFLD group compared to the control group. In addition, there was also a significant increase in both cardiac parameters and AST in the CAD group compared to the NAFLD group and the control group. Conclusion: Patients with coronary artery disease have higher Nesfatin-1 Concentration due to Nesfatin-1 having anti-inflammatory properties that raise the level of Nesfatin-1. In addition, Data from the current study showed a significant positive correlation between Nesfatin-1 and (ALT and AST) in NAFLD patients. However, further studies are needed to confirm this conclusion. Keywords: Coronary Artery Disease, Non-alcoholic fatty liver disease, Nesfatin1, Troponin-I
Improving" Jackknife Instrumental Variable Estimation method" using A class of immun algorithm with practical application
This article deals with the impact of including transverse ribs within the absorber tube of the concentrated linear Fresnel collector (CLFRC) system with a secondary compound parabolic collector (CPC) on thermal and flow performance coefficients. The enhancement rates of heat transfer due to varying governing parameters were compared and analyzed parametrically at Reynolds numbers in the range 5,000–13,000, employing water as the heat transfer fluid. Simulations were performed to solve the governing equations using the finite volume method (FVM) under various boundary conditions. For all Reynolds numbers, the average Nusselt number in the circular tube in the CLFRC system with ribs was found to be larger than that of the plain abs
... Show MoreDouble-layer micro-perforated panels (MPPs) have been studied extensively as sound absorption systems to increase the absorption performance of single-layer MPPs. However, existing proposed models indicate that there is still room for improvement regarding the frequency bands of absorption for the double-layer MPP. This study presents a double-layer MPP formed with two single MPPs with inhomogeneous perforation backed by multiple cavities of varying depths. The theoretical formulation is developed using the electrical equivalent circuit method to calculate the absorption coefficient under a normal incident sound. The simulation results show that the proposed model can produce absorption coefficient with wider absorption bandwidth compared w
... Show MoreIn this paper, chip and powder copper are used as reinforcing phase in polyester matrix to form composites. Mechanical properties such as flexural strength and impact test of polymer reinforcement copper (powder and chip) were done, the maximum flexural strength for the polymer reinforcement with copper (powder and chip) are (85.13 Mpa) and (50.08 Mpa) respectively was obtained, while the maximum observation energy of the impact test for the polymer reinforcement with copper (powder and chip) are (0.85 J) and (0.4 J) respectively
A series of laboratory model tests has been carried out to investigate the using of pomegranate sticks mat as reinforcement to increase the bearing capacity of footing on loose sand. The influence of depth and length of pomegranate sticks layer was examined. In the present research single layer of pomegranate sticks reinforcement was used to strengthen the loose sand stratum beneath the strip footing. The dimensions of the used foundation were 4*20 cm. The reinforcement layer has been embedded at depth 2, 4 and 8 cm under surcharge stresses . Reinforcing layer with length of 8 and 16 cm were used. The final model test results indicated that the inclusion of pomegranate sticks reinforcement is very effective in improvement the loading cap
... Show MoreIn solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational
... Show More