Preferred Language
Articles
/
uhc6WZABVTCNdQwCHIfk
DTM Extraction and building detection in DSMs having large holes
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Jul 01 2014
Journal Name
Ieee Transactions On Circuits And Systems I: Regular Papers
Crosstalk-Aware Multiple Error Detection Scheme Based on Two-Dimensional Parities for Energy Efficient Network on Chip
...Show More Authors

Achieving reliable operation under the influence of deep-submicrometer noise sources including crosstalk noise at low voltage operation is a major challenge for network on chip links. In this paper, we propose a coding scheme that simultaneously addresses crosstalk effects on signal delay and detects up to seven random errors through wire duplication and simple parity checks calculated over the rows and columns of the two-dimensional data. This high error detection capability enables the reduction of operating voltage on the wire leading to energy saving. The results show that the proposed scheme reduces the energy consumption up to 53% as compared to other schemes at iso-reliability performance despite the increase in the overhead number o

... Show More
View Publication
Scopus (25)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
2nd International Conference For Engineering Sciences And Information Technology (esit 2022): Esit2022 Conference Proceedings
Room temperature flexible sensor based on F-MWCNT modified by polypyrrole conductive polymer for NO2 gas detection
...Show More Authors

This project sought to fabricate a flexible gas sensor based on a short functionalized multi-walled carbon nanotubes (f-MWCNTs) network for nitrogen dioxide gas detection. The network was prepared by filtration from the suspension (FFS) method and modified by coating with a layer of polypyrrole conductive polymer (PPy) prepared by the oxidative chemical polymerization to improve the properties of the network. The structural, optical, and morphological properties of the f-MWCNTs and f-MWCNTs/PPy network were studied using X-ray diffraction (XRD), Fourie-transform infrared (FTIR), with an AFM (atomic force microscopy). XRD proved that the structure of f-MWCNTs is unaffected by the synthesis procedure. The FTIR spectra verified the existence o

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Aug 01 2019
Journal Name
Ieee Photonics Journal
Di-Iron Trioxide Hydrate-Multi-Walled Carbon Nanotube Nanocomposite for Arsenite Detection Using Surface Plasmon Resonance Technique
...Show More Authors

View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Dec 01 2013
Journal Name
Baghdad Science Journal
Detection of Anti-Helicopacter pylori IgG Antibody, Anti-GAD antibody, Anti-Beta islets cell in a sample of serum with type-2 Diabetes mellitus patients
...Show More Authors

We have investigated twenty five patients with type-2 diabetes mellitus aged (35-60) years and fifteen healthy persons as control group to detect Anti-Helicobacter pylori IgG antibody. All studied groups were carried out to measure fasting blood sugar, anti- Glutamic acid decarboxylase (GAD), anti-? islets cells antibody by IFAT, Anti-H. pylori IgG antibody by ELISA technique. There was significant elevation in the concentration of fasting blood sugar than in control group (P < 0.05), the patients had negative results for anti-GAD antibody and anti- ? islets cells antibody, there were significant differences (P < 0.05) of anti-H. pylori IgG antibody in 28 % of patients had type-2 diabetes than control group. This lead to suggestion that typ

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Biochemical & Cellular Archives
THE STUDY ON ABILITY OF ESCHERICHIA COLI ISOLATED FROM DIFFERENT CLINICAL CASES TO BIOFILM FORMATION AND DETECTION OF CSGD GENE RESPONSIBLE FOR PRODUCE CURLI (FIMBRIAE)
...Show More Authors

A total of 165 clinical sample included Urine, Swab wounds and Burns were collected from Baghdad Governorate. Results showed that rate all isolates of E. coli was 50(30.3%) and rate of urine infection was 46(92%) and rate of swab wounds infection 4(8%). Where was diagnostic based on streaked on MacConkey agar, then single colony was transferred to Eosin Methylene Blue (EMB). Identification some of the biochemical test included: Catalase test, Oxidase test, Indole test, Methyl red, Vogues - Proskauer test and Citrate Utilization test. Then confirmed by the Vitek - 2 Compact System. The ability of E.coli isolate to biofilm formation to be studied it is considered one of the most important factors of virulence and has role in causing injury an

... Show More
Scopus (2)
Scopus
Publication Date
Wed Oct 07 2020
Journal Name
Indian Journal Of Forensic Medicine &amp; Toxicology
Assessment the Effect of Lactobacillus Acidophilus on Escherichia Coli Serotype O157:H7 with Detection of Some Virulence Factors
...Show More Authors

Aim: To evaluation the effect of Lactobacillus acidophilus on Enterohemorrhagic Escherichia coli (EHEC) serotype O157:H7 with detection of some virulence factors. Methods: Two hundred and fifty specimens (stool) from children under five years for both sexes were collected from some hospitals. All isolates were diagnosed according to morphological characteristics, biochemical tests. Monoplex pattern of PCR was used also for detection different genes in (7) Escherichia coli )O157:H7 (isolates; include 16SrRNA, eae, lifA, Stx1,Stx2 that encoded for ribosomal RNA, intimin, lymphocyte inhibitory factor, shiga toxins. Three types of probiotics strains were obtained, Lactobacillus fermentum, Lactobacillus plantarum and Lactobacillus acidophilus (A

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Simulation Study on Optically Designed Refractive Beam Expander for Nd: YAG Laser Harmonics for 7 Km Detection Range
...Show More Authors

The simulation study has been conducted for the harmonics of Nd: YAG laser, namely the second harmonic generation SHG, the third harmonic generation THG, and the fourth harmonic generation FHG. Determination of beam expander's expansion ratio for specific wavelength and given detection range is the key in beam expander design for determining minimum laser spot size at the target. Knowing optimum expansion ratio decreases receiving unit dimensions and increases its performance efficiency. Simulation of the above mentioned parameters is conducted for the two types of refractive beam expander, Keplerian and Galilean. Ideal refractive indices for the lenses are chosen adequately for Nd: YAG laser harmonics wavelengths, so that increasing transm

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Sep 01 2016
Journal Name
Physica Medica
Quantitative analysis of sentinel lymph node detection using a novel small field of view hybrid gamma camera (HGC)
...Show More Authors

Introduction The Hybrid Gamma Camera (HGC) is being developed to enhance the localisation of radiopharmaceutical uptake in targeted tissues during surgical procedures such as sentinel lymph node (SLN) biopsy. Purpose To assess the capability of the HGC, a lymph-node-contrast (LNC) phantom was constructed for an evaluative study simulating medical scenarios of varying radioactivity concentration and SLN size. Materials and methods The phantom was constructed using two methyl methacrylate PMMA plates (8 mm thick). The SLNs were simulated by drilling circular wells of diameters ranging between 10 mm and 2.5 mm (16 wells in total) in one plate. These simulated SLNs were placed underneath scattering material with thicknesses ranging between 5 mm

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sat Dec 31 2016
Journal Name
Al-kindy College Medical Journal
A Comparison of Sagittal Sections of Short T1inversion Recovery and T2 Weighted Fast Spin Echo Magnetic Resonance Sequences for Detection of Multiple Sclerosis Spinal Cord Lesions
...Show More Authors

Background: Multiple sclerosis is a chronic autoimmune inflammatory demyelinating disease of the central nervous system of unknown etiology. Different techniques and magnetic resonance image sequences are widely used and compared to each other to improve the detection of multiple sclerosis lesions in the spinal cord. Objective: To evaluate the ability of MRI short tau inversion recovery sequences in improvementof multiple sclerosis spinal cord lesion detection when compared to T2 weighted image sequences. Type of the study: A retrospective study. Methods: this study conducted from 15thAugust 2013 to 30thJune 2014 at Baghdad teaching hospital. 22 clinically definite MS patients with clinical features suggestive of spinal cord involvement,

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Chemical Methodologies
Investigations on TiO<inf>2</inf>-NiO@In<inf>2</inf>O<inf>3</inf> Nanocomposite Thin Films (NCTFs) for Gas Sensing: Synthesis, Physical Characterization, and Detection of NO<inf>2</inf> and H<inf>2</inf>S Gas Sensors
...Show More Authors

Scopus (15)
Scopus