Preferred Language
Articles
/
uYausoYBIXToZYALdbG8
The effect of model scale, acceleration history, and soil condition on closed-ended pipe pile response under coupled static-dynamic loads
...Show More Authors

This paper analyzes the effect of scaling-up model and acceleration history on seismic response of closed-ended pipe pile using a finite element modeling approach and the findings of 1 g shaking table tests of a pile embedded in dry and saturated soils. A number of scaling laws were used to create the numerical modeling according to the data obtained from 1 g shake table tests performed in the laboratory. The current study found that the behaviors of the scaled models, in general have similar trends. From numerical modeling on both the dry and saturated sands, the normalized lateral displacement, bending moment, and vertical displacement of piles with scale factors of 2 and 35 are less than those of the pile with a scale factor of 1 and the shaking table test. In general, the pile deformation factor was higher in saturated sand models than the dry sand models. Liquefaction ratios were increased by increasing the seismic intensity; hence the maximum liquefaction ratio was observed with the model of scale 1 under the effect of the Kobe earthquake (0.82 g). In another full-scale model, the liquefaction ratio decreased significantly; i.e., it was decreased from 1.64% (λ = 1) to 1.04% (λ = 35) in the same mentioned model. Pile frictional resistance was numerically investigated and the overall results were compared with previous studies in the literature. In general, the frictional resistance at the pile tip was slightly higher than the frictional resistance around the pile body, and the frictional resistance factor on the ground surface of dry soil models was slightly higher than those of saturated soil models.

Scopus Crossref
Publication Date
Fri Nov 15 2024
Journal Name
Iraqi Journal Of Science
Stellar Thermonuclear Reaction Rates of Proton Radiative Capture by Closed Light Shell Isotopes
...Show More Authors

Light isotopes, especially closed shell nuclei, have significance in thermonuclear reactions of the Carbon-Nitrogen-Oxygen (CNO) cycle in stars. In this research, 12C(p, γ) 13N and 14N(p, γ) 15O reactions have been calculated by means of Matlab codes to find the reaction rate across a temperature range of 0.006 to 10 GK using non-resonant parts, as well as the astrophysical S- factor S(E) at low energies. It was concluded that the high binding energy of 12C and 14N nuclei make the reaction less probable thus enabling other competitive processes to develop, which enhances the probability of other competitive proton reactions in the CNO cycle.

View Publication
Scopus Crossref
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
K. wire fixation versus conservative treatment of closed displaced intra-articular calcaneal fractures
...Show More Authors

Background: Calcaneus is a spongy cancellous bone with rich blood supply , its fracture heals more rapidly providing no occurrence of infection and soft tissue injury around ,no gross malposition of fragments. The associated pain leads to a major impairment in life quality. The aim of treatment for calcaneal fractures is the decrease of pain and rebuilding of walking ability for patients with normal foot shape and the ability to wear normal foot wear. To reduce complications, a minimally invasive technique for the treatment of displaced intra-articular fractures of the calcaneus was preferred to use. The purpose of this study was to determine whether the closed reduction and percutaneous K. wire fixation of displaced intra-art

... Show More
Preview PDF
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Thermal Characteristics of Closed Wet Cooling Tower Using Different Heat Exchanger Tubes Arrangement
...Show More Authors

This paper presents thermal characteristics analysis of a modified Closed Wet Cooling Tower (CWCT) based on heat and mass transfer principles to improve the performance of this tower in Iraq. A prototype of CWCT optimized by added packing was designed, manufactured and tested for cooling capacity of 9 kW. Experiments are conducted to explore the effects of various operational and conformational parameters on the thermal performance. In the test section, spray water temperature and both dry bulb temperature and relative humidity of the air measured at intermediate points of the heat exchanger and packing. Heat exchangers consist of four rows and eight columns for an inline tubes arrangement and six rows and five columns f

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 30 2023
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The effect of operational efficiency on some financial indicators according to the CAMEL model of banking financial stability: An applied research on a sample of Iraqi private banks for the period 2010-2020
...Show More Authors

Abstract

          The research aims to determine the nature of the Iraqi market in terms of banking financial stability and the extent impact of the operational efficiency on it, Accordingly, chosen 15 relational banks were chosen as an intentional sample that could represent the Iraqi banking system for the period 2010-2020. The operational efficiency variable was measured according to the data envelope model, and banking financial stability used  CAMELS model which includes five indicators (capital adequacy, asset quality, management quality, profitability, and liquidity), so for testing the research hypotheses used the random regression model by adopting the S

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Revista Iberoamericana De Psicología Del Ejercicio Y El Deporte
The History of Clubs?: Participation in the Iraqi Volleyball Premier League and Its Results for the Period from (1991 to 2022)
...Show More Authors

The purpose of this paper is to identifying the results of the clubs participating in the men's Volleyball Premier League for the period from (1991) to (2022), archive the results of the Iraqi clubs participating in the Iraqi Premier League for men for the period from (1991) to (2022), and diagnosing and analyzing the causes of fluctuation in the participation of some Iraqi clubs in the Premier League for men for the period from (1991) to (2022). The nature of the research necessitated that the researcher use the historical approach or the so-called documentary approach, taking advantage of the historical development that took place for the participation of Iraqi clubs for men in the Premier League from (1991) until 2022), the last league h

... Show More
Publication Date
Fri Jun 05 2026
Journal Name
Revista Iberoamericana De Psicología Del Ejercicio Y El Deporte, Issn 1886-8576, Vol. 18, Nº. 3, 2023, Págs. 288-290
The History of Clubs?: Participation in the Iraqi Volleyball Premier League and Its Results for the Period from (1991 to 2022)
...Show More Authors

Autorías: Omar Saeed Sabbar, Ali Mousa Jawad, Maher Amer Jabbar. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 3, 2023. Artículo de Revista en Dialnet.

View Publication Preview PDF
Publication Date
Thu Jul 01 2021
The spontaneous emission performance of a quantum emitter coupled to a hybrid plasmonic waveguide with specified output polarization for on-chip plasmonic single-photon source
...Show More Authors

Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue May 11 2021
Journal Name
Photonics And Nanostructures - Fundamentals And Applications
The spontaneous emission performance of a quantum emitter coupled to a hybrid plasmonic waveguide with specified output polarization for on-chip plasmonic single-photon source
...Show More Authors

Nowadays, most of the on-chip plasmonic single-photon sources emit an unpolarized stream of single photons that demand a subsequent polarizer stage in a practical quantum cryptography system. In this paper, we numerically demonstrated the coupling of the light emitted from a quantum emitter (QE) at 700 nm wavelength to the propagation mode supported by an on-chip hybrid plasmonic waveguide (HPW) polarization rotator. Our results proved that the light emitted is linearly polarized at 0º, 45º/−45º, and 90º with propagation lengths of 5 μm, 3.3 μm, and 3.9 μm, respectively. Moreover, high power-conversion efficiency was obtained from an applied transverse magnetic (TM) mode (0º-polarization) to a transverse electric (TE) (90º-polari

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Scripta Medica
The value of dynamic contrast-enhanced MRI and diffusion-weighted sequence in the evaluation of endometrial lesions
...Show More Authors

Background/Aim: Endometrial abnormalities represent a diagnostic challenge due to overlapping imaging features with normal endometrium. Aim of this study was to assess accuracy of dynamic contrast-enhanced and diffusion-weighted magnetic resonance imaging (MRI) in evaluation of endometrial lesions in comparison with T2 and to assess local staging validity and degree of myometrial invasion in malignancy. Methods: Forty patients with abnormal vaginal bleeding or sonographic thickened endometrial were recruited. MRI examination of pelvis was per-formed using 1.5 T scanner with a pelvic array coil. Conventional T1-and T2, dynamic contrast-enhanced (DCE) sequences and diffusion-weighted image (DWI) were performed. Results: Mean age of pa

... Show More
View Publication
Crossref (1)
Scopus Crossref
Publication Date
Sun Jan 30 2022
Journal Name
Heat Transfer
Theoretical and experimental investigation of a heat pipe heat exchanger for energy recovery of exhaust air
...Show More Authors

Heat pipes and two‐phase thermosyphon systems are passive heat transfer systems that employ a two‐phase cycle of a working fluid within a completely sealed system. Consequently, heat exchangers based on heat pipes have low thermal resistance and high effective thermal conductivity, which can reach up to the order of (105 W/(m K)). In energy recovery systems where the two streams should be unmixed, such as airconditioning systems of biological laboratories and operating rooms in hospitals, heat pipe heat exchangers (HPHEs) are recommended. In this study, an experimental and theoretical study was carried out on the thermal performance of an air‐to‐air HPHE filled with two refrigerants as working fluids, R22 and R407c. The heat pipe he